Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JUNE 05, 2025 SAM #8592
SOLICITATION NOTICE

H -- Leak Detection of Pools-West Point FY25

Notice Date
6/3/2025 12:55:14 PM
 
Notice Type
Solicitation
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
W6QM MICC-WEST POINT WEST POINT NY 10996-1514 USA
 
ZIP Code
10996-1514
 
Solicitation Number
W911SD25RA017
 
Response Due
6/6/2025 1:30:00 PM
 
Archive Date
06/07/2025
 
Point of Contact
Sonya D. Van Valkenburg
 
E-Mail Address
sonya.d.vanvalkenburg.civ@army.mil
(sonya.d.vanvalkenburg.civ@army.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
The United States Military Academy (USMA) at West Point has a commercial requirement for service contract in which the Contractor will provide all labor, equipment, materials, and supervision necessary to perform water Leak detection inspection methods to find the areas leaking in the Cadet Pool bldg 727and Therapy Pool bldg 700B only. Between both pools at West Point, losing an average of 50K gallons a day. The contractor will conduct underwater inspection and leak detection of the pool system to locate any leaks and identify any failed concealed pipes responsible for water loses less evaporation. The services shall be provided in accordance with the Scope Of Work Statement (SOW). The customer is the United States Army Garrison West Point, Directorate of Public Works (USAGWP-DPW). DPW support�s the maintenance of the infrastructure at West Point. This is a commercial service requirement is new contract to detect document type of leaks, location and approximate rate of loss by written description and underwater photographs. The contractor will provide all labor, equipment, materials, and supervision necessary to perform water leak detection inspection of the Cadet Pool and Therapy Pool. The services shall be provided in accordance with the Scope Of Work Statement. The repair of the leaks is not included in this scope. Work Requirements: Leak detection methods to be used: *Filter equipment and concealed pipes will be isolated from the pool and balance tank by many temporary plugs so this portion can be checked for loss independently. *Balance tank will be isolated from the pool and filter system by temporary plugs so this portion can be checked for loss independently. *Pool will be isolated from the filter equipment and balance tank by temporary plugs so this portion can be checked for loss independently. *Underwater surfaces will be checked for the acoustic signatures of leaks and flows with an underwater microphone, particularly around 52 penetrations and many linear feet of discoloration areas. *Underwater surfaces of the pool and balance tank will receive an up-close visual inspection by diving in them and documenting voids and defects. Suspect areas will receive a dye test that makes a flow of water visible. *Penetrations in the pool and balance tank will be checked for leakage and defects by up-close visual inspection and either the dye test or flow test with a cofferdam. *Concealed pipes below the surface, including the bottom drainpipe, will be tested by isolating with test plugs and making a very low-pressure non-destructive test by detecting any flow from the vessel into the pipe. *Underwater lights and the niche in the pool wall containing them will be tested for any loss by isolating with a cofferdam and detecting any pressure differential caused by escaping water. *Leaks will be documented as to type, location, and approximate rate of loss by written description and underwater photographs. NOT IN THIS SCOPE: *Repair of leaks is not included in this scope. *If a loss is detected in a concealed pipe, the accessible pipe ends will be identified, but additional work with other specialized equipment to locate and document break(s) and hole(s) along the length of the concealed pipe is not in this scope. NAICS: 238220 and PCF:H345 size standard:$16.5MIL. In order to be eligible for award, business must be ractivitly registered in System for Award Management (SAM) at Sam.gov under the appropriate NAICS code. Please verify that both your Cage Code and Unique Entity ID are both current and valid. There will be no siste visit offered for this requirement. Offerors are reminded to carefully review solicitation documents issued as criteria as stated in the solicitation shall govern. Please see Scope of Work (SOW) attached. It is the Offeror's responsibility to check the Sam.gov website for any posted changes to this solicitation and all amendments. All oferor's shall submit their RFP to sonya.d.vanvalkenburg.civ@army.mil by close of solicitation. Also if you have and question please send questions to the same email address.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/fb088bf360d44f8aa21e048434ffef3a/view)
 
Place of Performance
Address: West Point, NY 10996, USA
Zip Code: 10996
Country: USA
 
Record
SN07463288-F 20250605/250603230044 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |