SOURCES SOUGHT
65 -- NX EQ Lifts: Patient Transfer: Floor: Loop Based
- Notice Date
- 5/28/2025 1:10:14 PM
- Notice Type
- Sources Sought
- NAICS
- 339113
— Surgical Appliance and Supplies Manufacturing
- Contracting Office
- STRATEGIC ACQUISITION CENTER FREDERICKSBURG (36C10G) FREDERICKSBURG VA 22408 USA
- ZIP Code
- 22408
- Solicitation Number
- 36C10G25Q0084
- Response Due
- 6/10/2025 1:30:00 PM
- Archive Date
- 09/17/2025
- Point of Contact
- Jalima J. Jones, Contract Specialist
- E-Mail Address
-
Jalima.Jones@va.gov
(Jalima.Jones@va.gov)
- Awardee
- null
- Description
- DESCRIPTION The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Lifts: Patient Transfer: Floor: Loop Based product line as a candidate for a VA-wide (otherwise referred to as national ) single Requirements contract award. The Department of Veterans Affairs (DVA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought Notice in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources. The SAC in conjunction with VHA is seeking a qualified source to provide EZ Way® brand name or equal the Lifts: Patient Transfer: Floor: Loop Based on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver the Lifts: Patient Transfer: Floor: Loop Based to VA medical centers and facilities throughout the United States and its territories. The anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation. The associated North American Industrial Classification System (NAICS) code for this procurement is 339113- Surgical Appliance and Supplies Manufacturing, Product Service Code: 6515 Medical and Surgical Instruments, Equipment, and Supplies and the associated size standard is 800 employees. The FAR Provision found at 52.204-7(b)(1) requires that All interested Offerors must be registered in SAM.gov prior to submitting an offer or quotation. You may access the website at SAM.gov | Home. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the SBA database at: https://veterans.certify.sba.gov/#search at the time of quote submission. Submissions for this source sought shall be submitted by email no later than June 5th, 2025, at 4:30pm EST to all the following: Jalima.Jones@va.gov Sara.Vickroy@va.gov This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes. 2.0 SCOPE Lifts: Patient: Transfer: Floor: Loop Based are designed for hoisting and transferring a patient safely and with minimal physical effort. These lifts consist of a C-shaped or U-shaped support base usually including casters, a vertical mast, a pivoting boom, a swivel bar, a hanger bar or spreader bar with hooks to accommodate loop-based slings, and the lifting mechanism; they are manually, electrically, or battery operated using hydraulic or screw jack lifting mechanisms. Patient lifts are frequently used to transfer patients (e.g., to and from a wheelchair, toilet, or bathtub), reducing the risk of injury to those assisting with the transfer (typically only one person) and of patient drop. The following Contract Line-Items Number (CLIN) are being considered: CLIN Manufacturer Part Number Description 0001 EZ Way L500PN-03 Loop-based full-body patient lift with loop-based hanger bar, 500-pound capacity minimum. 0002 EZ Way L500PS-03 Option for a Scale with the ability to lift with capacity equal to lift capacity. 0003 EZ Way LLB500PN Low base lift with option to fit under stretcher with 2.5-inch clearance. 0004 EZ Way 11871 Battery Replacement 0005 EZ Way 11860 Wall Mount Battery Charger 0006 EZ Way Caster Option Optional Caster Sizes (Lift is available in optional 2"", 4"" or 5"" caster) The Department of Veterans Affairs (VA) is seeking vendors who can provide EZ Way® brand name or equal Lifts: Patient Transfer: Floor: Loop Based as listed above or equal commodities which meet all the following salient characteristics (SCs): Apply to the following SC s to CLINs 0001 0002 SC # SALIENT CHARACTERISTICS METHOD OF EVALUATION SC 1 Options for multiple wheel heights, including an option of a low base that allows passage under a stretcher with 2.5-inch clearance and an option of 3-inch wheels or larger. Literature Review SC 2 Required to have an option for a scale that meets the full capacity of the lift. Literature Review SC 3 Weight capacity: 500 lbs. minimum. Literature Review SC4 Lifting must be motorized/battery powered. Literature Review SC 5 Lift must be tested in accordance with ISO 10535:2021 Literature Review SC 6 Lift must provide emergency stop and both electronic and manual emergency lowering. Literature Review SC 7 Must provide, or be compatible with, disposable, wipeable, and washable slings. Literature Review SC8 Lift must be allowed to be used for ambulation. Literature Review SC 9 Legs adjustable to a minimum interior width to accommodate a chair. Literature Review SC 10 Max exterior width with legs closed 27.5 Literature Review SC 11 Option to charge using a second battery and a wall charger. Literature Review SC 12 Lift must be allowed to be used with repositioning sling. Literature Review SC 13 Lifting range that allow floor rescue and ambulation of patients up to 6 feet tall (hanger bar hooks can reach 24.5 inches or lower and 70 inches or higher). Literature Review SC 14 Must be FDA approved for marketing. Literature Review Apply to the following SC s to CLIN s 0003-0006 SC # SALIENT CHARACTERISTICS METHOD OF EVALUATION SC 16 All Accessories must work with associated brand of lift Literature Review For each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above. The Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number. Responses to this Sources Sought Notice shall include the following: Does vendor offer an annual service plan, Yes or No? If Yes: What does the plan cover? Does plan cover software updates only? Does the plan cover parts repair or replacement only? Does the plan cover both software and parts? Vendor are requested to provide documentation that shows information on their service plan. Is the service provided by the OEM or a subcontractor? Full name and address of company DUNS number/ CAGE Code/ SAM UIE Business Size Manufacturer or Distributor If distributor provide full name, business size and address of manufacturer. Country of Origin designation for all products Ability to provide uninterrupted supply of products on a national scale. Technical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met. Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified. Although not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/2c0067f7c38d411bab9b084549ccc249/view)
- Place of Performance
- Address: Nationwide
- Record
- SN07458563-F 20250530/250528230059 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |