COMMERCE BUSINESS DAILY ISSUE OF MAY 14,1998 PSA#2095Department of the Army, Headquarters, Military Traffic Management
Office, ATTN: MTTM-T Room 629, 5611 Columbia Pike, Falls Church, VA
22041-5050 81 -- PURCHASE OF 20 X 20' ISO DRY AMMUNITION GRADE CONTAINERS SOL
DAMT01-98-Q-9925 DUE 051498 POC Sarah C. Wiley (703) 681-9770 WEB:
wileys@baileys-emh5.army.mil, wileys@baileys-emh5.army.mil. E-MAIL:
wileys@baileys-emh5.army.mil, wileys@baileys-emh5.army.mil. See Note 1.
The Government requires the purchase of ISO Ammunition Grade containers
as described below. Subject containers must be delivered as specified
in the description provided. If the RDD provided below can not be met,
please provide your earliest availability for delivery any units that
are offered in response to this request for quotes. NOTE: THIS
REQUIREMENT IS SET ASIDE EXCLUSIVELY FOR PARTICIPATION BY SMALL
BUSINESSES. THE SMALL BUSINESS SIZE STANDARD IS 500 EMPLOYEES FOR SIC
3441. Please provide unit price, drayage and all other related costs
below as applicable. All containers purchased by the Government must
have not less than (NLT) one set of fork lift pockets. Container(s)
must have current CSC inspection valid for 30 months, and be ammunition
grade, less than two years old. Cargo/sea worthy condition inspection
incorporates the following: 1. ISO -- No alteration of K-1,K-2,
dimensions. 2. WELDS -- No cracked welds on the welds of prime
structural components. 3. PANELS—Dents, bonds and bows up to 50mm
into the cube. 4. CORNER POSTS -- Dents to 25mm. 5. TOP SEARAILS --
Dents to 25mm. 6. HEADERS -- Front 25mm, Rear 35mm. 7. BOTTOM RAILS --
Dents up to 50mm (no limit on flanges). Flange comes up to webs,
except on bottom side rails. 8. FLP SIDES, CROSSMEMBERS TUNNELS RAILS
AND BOLSTERS -- Debris up to 75mm (no limit on flanges) horizontal cuts
in webs to 400mm. Flange cuts up to welds. 9. DOORS -- Operable, light
& watertight and sealable. 10. FLOOR GOUGES -- Up to 15mm deep and
150mm wide, 5mm deep over 150mm wide, uneven adjacent boards/threshold
plate up to 5mm. 11. FLOOR SEPARATION -- Up to 10mm at fastener. 12.
RAIN GUTTERS & J BARS -- No interfering with the door. 13. VENTS --
Functioning and watertight or closed off. 14. MARKINGS -- All serial
numbers and IS required markings must be legible. TIR and CSC plates
must be present. 15. GENERAL -- No missing door hardware. No holes into
the cube. No cuts except as noted above. No corrosion that will not
pass a hammer test. No hazardous cargo residues or foul odors.
Containers are to be delivered FOB Destination. 98-041 Details are
provided as follows: 20 x 20' ISO Dry Ammo Grade Containers, less than
two years old, delivered to: Marine Corps Base Lot #201 Camp LeJeune,
NC POC: CWO2 Jones (918) 451-8413/8891 Alt POC: SSGT Britt (910)
451-8891 Required Delivery Date: 28 May 1998. Truckers are required to
call 24 hours prior to arrange for delivery. Please allow for possible
training holidays. Acceptance inspection required. (The Government may
inspect equipment at the depot of origin. Facility hours of operation
are 0730 -- 1630, M-F Price Proposal: Qty Unit Price Extended Price
CLIN 0001 ___ EA $__ __ __ __ $__ __ __ ___ 20' ISO Container(s) CLIN
0002 ___ EA $_&llmdash; __ __ __ $__ __ __ ___ Delivery Depot of origin
of units offered under this proposal. Name:__ __ __ __ __ ___ Street:__
__ __ __ __ ___ City/State/Zip:__ __ __ __ ___ Please submit your offer
to Sarah Wiley by facsimile NLT 12:00 on 14 May 1998 @ (703) 681- 9112.
If you have any problem receiving this transmission, please call
Burnita Bell at (703) 681-5620 for help. SARAH WILEY CONTRACTING
OFFICER (0131) Loren Data Corp. http://www.ld.com (SYN# 0355 19980514\81-0001.SOL)
81 - Containers, Packaging and Packing Supplies Index Page
|
|