Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF MAY 14,1998 PSA#2095

Department of the Army, Headquarters, Military Traffic Management Office, ATTN: MTTM-T Room 629, 5611 Columbia Pike, Falls Church, VA 22041-5050

81 -- PURCHASE OF 20 X 20' ISO DRY AMMUNITION GRADE CONTAINERS SOL DAMT01-98-Q-9925 DUE 051498 POC Sarah C. Wiley (703) 681-9770 WEB: wileys@baileys-emh5.army.mil, wileys@baileys-emh5.army.mil. E-MAIL: wileys@baileys-emh5.army.mil, wileys@baileys-emh5.army.mil. See Note 1. The Government requires the purchase of ISO Ammunition Grade containers as described below. Subject containers must be delivered as specified in the description provided. If the RDD provided below can not be met, please provide your earliest availability for delivery any units that are offered in response to this request for quotes. NOTE: THIS REQUIREMENT IS SET ASIDE EXCLUSIVELY FOR PARTICIPATION BY SMALL BUSINESSES. THE SMALL BUSINESS SIZE STANDARD IS 500 EMPLOYEES FOR SIC 3441. Please provide unit price, drayage and all other related costs below as applicable. All containers purchased by the Government must have not less than (NLT) one set of fork lift pockets. Container(s) must have current CSC inspection valid for 30 months, and be ammunition grade, less than two years old. Cargo/sea worthy condition inspection incorporates the following: 1. ISO -- No alteration of K-1,K-2, dimensions. 2. WELDS -- No cracked welds on the welds of prime structural components. 3. PANELS—Dents, bonds and bows up to 50mm into the cube. 4. CORNER POSTS -- Dents to 25mm. 5. TOP SEARAILS -- Dents to 25mm. 6. HEADERS -- Front 25mm, Rear 35mm. 7. BOTTOM RAILS -- Dents up to 50mm (no limit on flanges). Flange comes up to webs, except on bottom side rails. 8. FLP SIDES, CROSSMEMBERS TUNNELS RAILS AND BOLSTERS -- Debris up to 75mm (no limit on flanges) horizontal cuts in webs to 400mm. Flange cuts up to welds. 9. DOORS -- Operable, light & watertight and sealable. 10. FLOOR GOUGES -- Up to 15mm deep and 150mm wide, 5mm deep over 150mm wide, uneven adjacent boards/threshold plate up to 5mm. 11. FLOOR SEPARATION -- Up to 10mm at fastener. 12. RAIN GUTTERS & J BARS -- No interfering with the door. 13. VENTS -- Functioning and watertight or closed off. 14. MARKINGS -- All serial numbers and IS required markings must be legible. TIR and CSC plates must be present. 15. GENERAL -- No missing door hardware. No holes into the cube. No cuts except as noted above. No corrosion that will not pass a hammer test. No hazardous cargo residues or foul odors. Containers are to be delivered FOB Destination. 98-041 Details are provided as follows: 20 x 20' ISO Dry Ammo Grade Containers, less than two years old, delivered to: Marine Corps Base Lot #201 Camp LeJeune, NC POC: CWO2 Jones (918) 451-8413/8891 Alt POC: SSGT Britt (910) 451-8891 Required Delivery Date: 28 May 1998. Truckers are required to call 24 hours prior to arrange for delivery. Please allow for possible training holidays. Acceptance inspection required. (The Government may inspect equipment at the depot of origin. Facility hours of operation are 0730 -- 1630, M-F Price Proposal: Qty Unit Price Extended Price CLIN 0001 ___ EA $__ __ __ __ $__ __ __ ___ 20' ISO Container(s) CLIN 0002 ___ EA $_&llmdash; __ __ __ $__ __ __ ___ Delivery Depot of origin of units offered under this proposal. Name:__ __ __ __ __ ___ Street:__ __ __ __ __ ___ City/State/Zip:__ __ __ __ ___ Please submit your offer to Sarah Wiley by facsimile NLT 12:00 on 14 May 1998 @ (703) 681- 9112. If you have any problem receiving this transmission, please call Burnita Bell at (703) 681-5620 for help. SARAH WILEY CONTRACTING OFFICER (0131)

Loren Data Corp. http://www.ld.com (SYN# 0355 19980514\81-0001.SOL)


81 - Containers, Packaging and Packing Supplies Index Page