Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF APRIL 2,1998 PSA#2065

National Cancer Institute, Research Contracts Branch, PSAS, 6120 Executive Blvd, EPS/Room 638, Bethesda, MD 20892-7227

66 -- 1000 WATT RF POWER AMPLIFIER SOL NCI-RFQ-80114-NE POC David Keefer, Contracting Officer, (301)496-8628; William Taylor, Contract Specialist, (301) 496-8628 This is a combined synopsis/solicitation for commercial items, prepared in accordance with the format in FAR 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation and a separate written solicitation will not be issued. This solicitation, No. NCI-RFQ-80114-NE will include all applicable provisions and clauses in effect through FAR FAC 97-04. The acquisition is being made in accordance with the test program for using simplified procedures for certain commercial items authorized in FAR 13.6. The solicitation is set-aside for small businesses. The Standard Industrial Classification Code is 3826 and the business size standard is 500 employees. Background: The Radiation Biology Branch, National Cancer Institute, is developing a Radiofrequency (RF) pulsed Electron Paramagnetic Resonance Spectrometer/imager in order to perform non-invasive physiologic imaging of tissues of intact biologic objects. Current studies have provided the proof of principle in animal models. The next step is to scale the studies up to perform similar experiments on larger objects in the scale, at least, of the human head. Since the requirements of RF power increase significantly with object size, the input RF pulse power to the object must be amplified to at least 1000 watts. This is important in the detection and imaging of free radicals and physiology in larger objects. The pulse widths in EPR experiments are in 10-50 nanoseconds to achieve the desired spectral bandwidth (20-100 MHz). Unlike in NMR experiments, the spectral range of EPR experiments is higher. The frequency range of the EPR imaging experiments is in the range of 100 MHz to 1000 MHz in a single band operation. Therefore, an instantaneous frequency response of the amplification in this frequency range is required. Furthermore, the amplification of the input signal must be distortion (harmonic) free and be biased in the linear range of the amplifier in order for the experiment to be free of artifacts associated with pulse amplification. In addition, the pulses have to be amplified to the desired level with rise times in the order a nanosecond. Since the pulse widths are in 10 ns range, rise times in the order of 1 ns are required. Similar requirements in the fall times are desired as well to ensure the amplification of square wave form. Requirement: The National Cancer Institute is soliciting quotations for pulse power amplifier equipment to meet the foregoing program need. The equipment must meet the following specific requirements: 1) Maximum output power: 1000 Watts 2) Frequency Response: 100 MHz to 1000 MHz; single band operation. 3) Class of operation: Class A bias condition 4) Input and output impedance: 50 Ohms 5) Modulation: 100% in pulse, AM and FM 6) Control: Front panel and remote 7) Monitoring: Forward and reflected power 8) Gain Control: To be provided in front panel 9) Maximum input: 0 dBm 10) Cooling: Forced air cooling required 11) Rise Time/FallTime: 1 -2 nanoseconds 12) Annunciation: Continuous monitoring and identification of fault circuits or modules. The equipment shall have a minimum warranty period of one (1) year, including parts and labor. Delivery shall be made F.O.B Destination, inside delivery, no later than 90 days after receipt of order Offerors must provide descriptive literature, warranties, and/or other materials that demonstrate that their offer meets the foregoing requirements. The contract will be awarded to the responsible offeror with the lowest-price offer that fully meets the requirements of the solicitation. This solicitation incorporates the provisions at FAR 52.212-1, INSTRUCTIONS TO OFFERORS-COMMERCIAL ITEMS, and at FAR 52.212-3, OFFEROR REPRESENTATIONS AND CERTIFICATIONS -- COMMERCIAL ITEMS. The latter provision includes the DUNS Number Addendum. The resulting contract will incorporate the requirements of the clause at FAR 52.212-4, CONTRACT TERMS AND CONDITIONS -- COMMERCIAL ITEMS, and the requirements contained in paragraphs (a) and (d) of the clause at FAR 52.212-5, CONTRACT TERMS AND CONDITIONS REQUIRED TO IMPLEMENT STATUTES OR EXECUTIVE ORDERS -- COMMERCIAL ITEMS -- DEVIATION FOR SIMPLIFIED ACQUISITIONS. The contract will also incorporate the following FAR clauses cited in paragraphs (b) and (c) of the latter clause: FAR 52.222-26, EQUAL OPPORTUNITY; FAR 52.222-35, AFFIRMATIVE ACTION FOR SPECIAL DISABLED AND VIETNAM ERA VETERANS; FAR 52.222-36, AFFIRMATIVE ACTION FOR HANDICAPPED WORKERS; FAR 52.222.37, EMPLOYMENT REPORTS ON SPECIAL DISABLED VETERANS AND VETERANS OF VIETNAM ERA; and FAR 52.225-3, BUY AMERICAN ACT -- SUPPLIES. Offers are due 30 days after the publication date of this notice at 5:00 p.m. EST. Facsimile submission is not authorized. Offers must be in writing and should be submitted as follows: (1) one original and two copies of a completed SF 18 or SF 1449, signed by an individual authorized to bind the organization; (2) a Schedule of Offered Supplies/Services containing pricing for the system being offered, published price lists (if applicable), and a delivery schedule; (3) completed Representations and Certifications -- Commercial Items, with DUNS Number addendum; (4) descriptive literature indicating that the offer meets the stated requirements; (5) acknowledgment of amendments, if any. The Representations and Certifications must be signed by an authorized representative of the offeror. Full text copies of the Representations and Certifications or other cited provisions and clauses may be obtained from David Keefer or William Taylor, on (301) 496-8628 or by fax on (301) 480-0309. Offers and related materials must be submitted to David Keefer at the listed address. Offers that fail to furnish the required information or reject the terms and conditions of the solicitation may be excluded from consideration. Please cite the solicitation number on your offer. (0090)

Loren Data Corp. http://www.ld.com (SYN# 0342 19980402\66-0009.SOL)


66 - Instruments and Laboratory Equipment Index Page