Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 18,1998 PSA#2034

Federal Emergency Management Agency, Mt. Weather Emergency Assistance Center, 19844 Blue Ridge Mountain Road, Bluemont, VA 20135

41 -- AC UNIT SOL EMV-1998-RQ-0014 POC Jennie K. Nickleson, 540/542-2133 E-MAIL: EMV-1998-RQ-0014, jennie.nickleson@fema.gov. This is a combined synopsis/solicitation according to the format in FAR Subpart 12, as supplemented with additional information included in this notice. EMV-1998-RQ-0014 is to purchase of a self-contained air conditioner, 30 ton 11,000 CFM 280V, 60 HZ, 3 PH., 1 each. The air conditioner unit contains the following listed items: CABINET: The unit framework shall be formed structural steel members of 14-gauge galvanized steel. Exterior panels shall be fabricated from 18-gauge galvanized steel. The unit exterior shall be painted with air dry enamel paint. The fan and compressor sections shall be insulated with -inch of 1.75 pound density fiberglass insulation. The unit shall be provided with removable panels to allow service access to compressors, condensers, fan motor, fan bearings, coils and valves. Serviceable panels shall be secured with quick-acting fasteners. The refrigerant sight glasses shall be accessible during operation. The control panel door shall have lift-off hinges. All panels shall be self-supporting. COMPRESSOR: Shall be manufactured by the unit manufacturer. Units shall have multiple compressors with independent circuits. Scroll compressors shall be heavy-duty, suction-cooled type with suction screen, centrifugal oil pump with dirt separator, oils sight glass and oil charging valve. Protective devices for low pressure, high pressure and motor temperature shall be provided. The compressors shall be mounted on rubber-in-shear isolators for vibration insolation. CONDENSER: One condenser shall be provided for each compressor. The condensers shall be shell-and-tube design with removable heads and mechanically cleanable tubes. Condenser tubes shall be nominal inch. O.D. copper. Condenser waterside working pressure shall be 400 psig. Unit will allow condenser water piping to be brought to the condensers from the right side of the unit. All water piping including economizer valve package shall be manifolded into a single inlet and outlet and extended to the exterior of the unit. EVAPORATOR: The evaporator coil shall be seamless copper tubes expanded into aluminum fins. Tubes shall be -inch O.D. with internally enhanced surfaces. The coil shall have a staggered tube arrangement with interlaced circuiting and no more than 12 fins per inch. The drain pan shall be fabricated of stainless steel and be insulated with -inch of one pound density fiberglass. Drain piping shall be provided to the exterior of the unit. REFRIGERANT CIRCUIT: Shall be independent and completely piped including filter driers, sight glasses, distributors, expansion valves with adjustable superheat and external equalizer, and high pressure relief valves with a -inch SAE flare connection. The circuits shall be tested, dehydrated and then charged with oil and Refrigerant-22. SUPPLY FAN, DRIVE AND MOTOR: The supply fan shall be dual, forward curved medium pressure fans secured to a solid steel shaft with grease-lubricated bearings designed for 200,000 hours. The drive components shall include fixed-pitch sheaves and multiple V-belts sized for 150 percent of nominal motor horsepower. The supply fan motor shall be high efficiency open drip-proof. The supply fan motor shall have a standard T-frame. The entire fan assembly, including drive components, shall be mounted on a common base. The fan base shall be isolated inside the unit. The entire assembly shall be statically and dynamically balanced at the factory to a maximum tolerance of 3 mils peak to peak. FAN MODULATION: The variable volume unit shall operate at design airflow based on fan and motor drive selections. Fan and motor sheaves will be selected for a rpm to develop airflow at design static pressure. INLET GUIDE VANES: Airflow modulation shall be by inlet guide vanes. The inlet vanes, complete with electric actuator, linkage and controller shall be factory-installed and adjusted. The static pressure setpoint shall be adjustable. A duct static pressure sensing probe shall be provided for field-installation. FILTERS: Two-inch medium velocity throwaway filters shall be provided for unit operation. UNIT CONTROLS: Unit Control Module -- The microprocessor controller shall control all unit functions, including the economizer, mechanical refrigeration and fan modulation and monitor diagnostics. All controls shall be factory installed and adjusted. The controller shall include a switch to place the unit in Auto Remote, Auto Local or Stop/Reset mode; an indicator display to show unit operating status, diagnostics and setpoints; and adjustable setpoints for supply air temperature, supply air pressure, economizer minimum position, supply air temperature control band and supply air pressure high static limit. The three-position switch and indicator display shall be accessible without opening any unit panels. ENTERING AIR TEMPERATURE PROTECTION: A single-point sensor is used to detect entering air temperature to the unit. If entering air temperature to the unit exceeds 135 F or falls below 37 F, the unit will shut down and dispay a diagnostic code. Manual reset is required when the entering airtemperature rises above 135 F. RATINGS: Design cooling capacity shall be 30 tons nominal based on standard ARI conditions. Designs airflow shall be 11,000 CFM @ 0.65" E.S.P. Power supply shall be 208 volts, 60 Hertz, 3 phase. DIMENSIONS: Unit dimensions shall not exceed 95" high, 90" wide and 52" deep with all options and accessories installed. The unit shall be shipped in separate sections such that it can be transported through a freight elevator and a 35" wide doorway and assembled in place. ACCESSORIES to be provided: 1) discharge plenum for mounting on top of the unit. Discharge opening shall be field cut. 2) unit mounted electrical disconnect switch, 3) 5 year compressor warranty, 4).Spring isolators, 5) water flow switch, 6) UL approved, 7) water side economizer. It shall be 4 row, mechanically cleanable and shall be shipped separately for installation in place. Modulating valves shall be provided for control of water flow through the economizer. SUBMITTALS: Three sets of shop drawings shall be submitted for approval prior to fabrication of the unit. Construction and delivery shall not proceed until one set of drawings has been returned approved. Please provide manufacturer's name and model number of proposed product. In addition, provide descriptive literature of the product being offered in order for the Government to determine if the offered product meets the Government's minimum requirements. Failure to provide descriptive literature for proposed product will result in your offer not being considered. This announcement constitutes the only solicitation; quotes are being requested and a written request for quotes will not be issued. The solicitation is issued as a Request for Quotes (RQ). Contractor must meet all requirements detailed in this synopsis. Government's desired delivery time is 60 days. Please specify best delivery time upon approval of the submitted drawings. Include shipping charges, if any, in your quote as a separate line item. It is anticipated that a firm-fixed price single award purchase order will result from this RFQ. Price is of greater importance when compared with technical. Quoters must include with the pricing any shipping costs applicable to this procurement. Quoters are to include a completed copy of the provisions at 52.212-3 Offeror Representations and Certifications-Commercial Items with this quote. The following clauses also apply 52.212-1 Instruction to Offers-Commercial Items, 52.212-2 Evaluation Commercial Items, 52-212-4 Contract Terms and Conditions-Commercial Items, 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Order-Commercial Items, 52.222-26 Equal Opportunity (E.O.11246), 52.222-35 Affirmative Action for Special Disabled and Vietnam Era Veterans (38 U.S.C. 4212), 52.222-36 Affirmative Action for Handicapped Workers (29 U.S.C. 793), 52.225-3 Buy American Act-Supplies (41 U.S.C. 10). All responsible sources may submit a quote, which shall be considered. The SIC 3585, the small business size standard is 750 employees. The due date for submission of quotes is February 27, 1998, at 10:00 A.M., local time, to FEMA, Mt. Weather Emergency Assistance Center, 19844 Blue Ridge Mountain Road, Bluemont, Virginia 20135. All requests for information are to be addressed to Mrs. Jennie K. Nickleson, Contract Specialist, at 540-542-2133. Technical and/or administrative questions must be received no later than five business days after publication of this notice and may be faxed to 540/542-2631/2632 or mailed to the address for submission of quotes shown above. Any amendments to this solicitation will be published in the same manner as the initial synopsis/solicitation. (0043)

Loren Data Corp. http://www.ld.com (SYN# 0241 19980218\41-0005.SOL)


41 - Refrigeration, Air Condition and Air Circulating Equipment Index Page