Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 17,1996 PSA#1681

Commanding Officer (B340), Marine Corps Logistics Base, Contracting and Purchasing, Box 110340, Barstow, CA 92311-5039

66 -- MACHINE, MEASURE, HELIO-COMPSUPRA SOL M6220496R0023 DUE 110496 POC Theresa Shenouda, 619-577-6437, Fax 619-577-6174. Helio-Com Supra P/N 27764054 or equal, Machine must be capable of measuring inside and outside diameter measurements, the maximum outside measurement capability should be no less than 0 to 500mm, while the maximum inside measurement should be no less than 0 to 300mm. The minimum requirements for calibration equipment types are plug gages, ring gages, snap gages, thread gauges, dial indicators, micrometers, setting masters and items in this workload area. The dimensions must not exceed 1300mm in length, 370mm in width and 395mm in height and not weigh than 300kg. The system must come with a microprocessor controller for the error compensating software. The Measuring Uncertainty should be no less than (0,2+L/200)um at (20+0.2)degree C and (0,2 + L/600) um at (20+ 3.0) degree C, with repeatability at 0,1um. To be delivered to the Marine Corps logistics Base, Barstow, Ca. 92311. All responsible sources may submit a proposal which will be considered by the Agency. (0257)

Loren Data Corp. http://www.ld.com (SYN# 0295 19960916\66-0012.SOL)


66 - Instruments and Laboratory Equipment Index Page