Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MARCH 07, 2025 SAM #8501
SOURCES SOUGHT

42 -- 36C242-25-AP-2049 | 528-25-2-6087-0027 Brand name or Equal Bauer Unicus 4S/25H-E3 6000 PSI Fire Edition Compressor / Bath VAMC Fire Department

Notice Date
3/5/2025 11:17:18 AM
 
Notice Type
Sources Sought
 
NAICS
333912 — Air and Gas Compressor Manufacturing
 
Contracting Office
242-NETWORK CONTRACT OFFICE 02 (36C242) ALBANY NY 12208 USA
 
ZIP Code
12208
 
Solicitation Number
36C24225Q0414
 
Response Due
3/12/2025 9:00:00 AM
 
Archive Date
06/19/2025
 
Point of Contact
Corey Swinton, Contracting Officer
 
E-Mail Address
Corey.Swinton@va.gov
(Corey.Swinton@va.gov)
 
Awardee
null
 
Description
STATEMENT OF WORK (SOW) As of 02/26/2025 1. Contracting Officer s Representative (COR). . Name: Mark LaBarr Section: Logistics Address: 76 Veterans Avenue, Bath NY 14810 Phone Number: 607-664-4877 Fax Number: E-Mail Address: Mark.LaBarr@va.gov 2. Contract Title. Brand Name or Equal: Bauer UNICUS 4/S25H-E3 N1 6000 PSI Compressor. 3. Background. The Bath VA Medical Center Fire Department relies on a high-pressure air compressor to fill self-contained breathing apparatus (SCBA) cylinders, which are essential for firefighter safety during emergency response operations. The current compressor has reached the manufacture s end-of-life, meaning it is outdated, and increasingly difficult to maintain. 4. Scope. The purpose of this Statement of Work (SOW) is to procure and install a BAUER UNICUS 4S/25H-E3 N1 6000 PSI Compressor, Fire Edition or an equal unit that meets or exceeds the specified technical and performance requirements, for the Bath VA Medical Center Fire Department. This unit will replace the current, outdated compressor, which has reached the manufacturer s end-of-life and received multiple work orders for repairs. The new system will ensure reliable and efficient high-pressure air compression for critical fire department operations. 5. Requirements. 5.1 Equipment Specifications. Compressor Model: Fire Edition BAUER UNICUS 4S/25H-E3 N1 6000 PSI or equal. Edition: Fire Edition Specialized package designed to align aesthetically with fire department themes. Operating Pressure: 6000 PSI Horsepower: 20 HP Charging Rate: 25.2 CFM Filtration System: P5 Securus Filtration System or equal Compressor Stages: 5-stage with interstage pressure gauges. Condensate Drain System: Automatic condensate drain system with non-corrosive condensate reservoir. Fill Station: Three-position fill station. Storage Cylinders: Four ASME-certified cylinders mounted on the back of the unit. Safety Features: Low oil shutdown High-temperature shutdown. NEMA 4 rated electrical enclosure Emergency stop push button Audible alarm on safety shutdowns Additional Features: Electronic CO monitor Integrated real-time CO monitoring system to ensure air safety. Remote fill connection Anables convenient remote refilling of SCBA cylinders in different locations. 5.2 Additional Specifications. Access Doors: Snap pin technology 7 color HMI touchscreen display NFPA 1901 2016 edition compliant 3 position containment fill station Dimensions: 101 x 38 x 78 to fit in the only designated area Weight: 4550 lb Fill Station: Three-position SCBA fill station to allow for simultaneous refilling of up to three cylinders. 5.2 Installation and Service. Installation: Vendor shall deliver and install the compressor at the Bath VA Medical Center Fire Department, ensuring full operational functionality. Air Quality Test: A certified air quality test must be conducted at startup to ensure compliance with applicable air purity standards. Training: The vendor shall provide hands-on training for designated fire department personnel, covering operation procedures, routine maintenance, and safety protocols. 6. Delivery & Performance Criteria. The contractor shall complete delivery, installation, testing, and training within 6 months from the date of contract award. 7. Acceptance Criteria. The unit shall meet all performance and specifications outlined in Section 2. The installation must be verified for full functionality, including a successful air quality test. Training must be completed, and designated personnel must demonstrate operational competency 8. Security. The C&A requirements do not apply, and a Security Accreditation Package is not required. 10. Place of Performance. Bath VA Medical Center 76 Veterans Avenue Building 14 Fire Department Bath, NY 14810
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/8c423f1a4fda4d50aa1311125f831cf1/view)
 
Place of Performance
Address: Bath VA Medical Center 76 Veterans Avenue Building 14 Fire Department, Bath, NY 14810, USA
Zip Code: 14810
Country: USA
 
Record
SN07362465-F 20250307/250307070543 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.