Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF OCTOBER 10, 2021 SAM #7253
SOURCES SOUGHT

99 -- Oxford EDS/EBSD system maintenance

Notice Date
10/8/2021 7:49:07 AM
 
Notice Type
Sources Sought
 
NAICS
811219 — Other Electronic and Precision Equipment Repair and Maintenance
 
Contracting Office
DEPT OF COMMERCE NIST GAITHERSBURG MD 20899 USA
 
ZIP Code
20899
 
Solicitation Number
AMD-SS22-01
 
Response Due
10/22/2021 3:00:00 PM
 
Archive Date
11/06/2021
 
Point of Contact
Forest Crumpler
 
E-Mail Address
forest.crumpler@nist.gov
(forest.crumpler@nist.gov)
 
Description
The National Institute of Standards & Technology (NIST) seeks information on commercial vendors that are capable of providing a 5 year preventive maintenance, calibration and emergency service contract, consisting of a base year plus 4 option years, for an Oxford Aztec X-MaxN 80 Energy Dispersive Spectrometer (EDS) systems and Nordlys Electron Backscatter Diffraction (EBSD) system. The EDS and EBSD system is mounted on Thermo Fisher (FEI) Helios 660 Dual Beam electron microscope that is located NIST Center for Nanoscale Science and Technology (CNST) in Gaithersburg, MD.� The system is used as shared resource that is accessible to researchers from industry, academia, NIST and other government agencies. The service contract is required to keep the system operational, with minimal interruption in service so it is available for use 24 hours per day and 7 days a week. NO SOLICITATION DOCUMENTS EXIST AT THIS TIME After the results of the market research are obtained and analyzed, and specifications are developed for the preventive maintenance service contract for the Oxford EDS and EBSD system that can meet NIST's minimum requirements, NIST may conduct a competitive procurement and subsequently award a Purchase Order.� If at least two qualified small businesses are identified during this market research stage, then any competitive procurement that resulted would be conducted as a small business set-aside. GENERAL Provide a 5 year preventive maintenance and emergency service contract for an Oxford Aztec X-MaxN 80 EDS system and Nordlys EBSD system. The contract shall consist of a base year plus 4 option years. REQUIREMENTS:� This service contract shall consist of one preventative maintenance and calibration visit per year and emergency service as needed. The EDS and EBSD systems shall be serviced by factory-certified personnel and only OEM parts shall be used. Service engineers shall be equipped with all the tools required to perform all services. The contract will cover labor and travel. EQUIPMENT COVERED:� The following tools shall be covered by this service contract. Oxford Aztec mics/X-stream2//X-Max 80 EDS///Nordlys system (Serial Number:� 63394//57832///NL04-2326-30) which are mounted on a Thermo Fisher Helios NanoLab 660. Covered equipment includes all integrated system components, detectors, mics boxes, x-stream2 boxes, pulse processors and software updates or modifications. SCHEDULED SERVICE:� The vendor shall perform a minimum of 1 preventive maintenance and calibration service visit per year on each tool. This service will include installation of software modifications and verification of system performance. PERFORMANCE METRICS:� The Vendor shall provide a written annual report documenting the performance of the detectors. The units shall meet the manufacturer�s quoted resolution specification. UNSCHEDULED SERVICE:� Priority phone service shall be provided within 1 business day and parts and or a service engineer will be sent if phone service does not solve the problem. Broken detectors will be either exchanged or repaired. The broken detectors will be returned to the Oxford Instruments� US repair facility. �If the detector requires repair or testing that can only performed under original manufacturing conditions, then the detector shall be returned to Oxford Instruments� United Kingdom Manufacturing Facility. SERVICE PERSONEL:� The vendor shall be capable of providing in advance the full name and citizenship of each service personnel that will require NIST campus access.� For any personnel that are not US citizens or permanent residents, this information must be provided at least three days in advance. NIST is seeking responses from all responsible sources, including large, foreign, and small businesses. Small businesses are defined under the associated NAICS code for this effort, 811219, as those domestic sources with a size standard of $22M or less. Please include your company�s size classification and socio-economic status in any response to this notice.� � Companies that can provide a preventative maintenance service contract for an Oxford Aztec X-MaxN 80 EDS systems and Nordlys EBSD system are requested to email a detailed report describing their abilities to forest.crumpler@nist.gov no later than the response date for this sources sought notice. The report should include achievable specifications and any other information relevant to your product or capabilities. Also, the following information is requested to be provided as part of the response to this sources sought notice: 1. Name of the company that manufactures the system components for which specifications are provided. 2. Name of company(s) that are authorized to sell the system components, their addresses, and a point of contact for the company (name, phone number, fax number and email address). 3. Indication of number of days, after receipt of order that is typical for delivery of such systems. 4. Indication of whether each instrument for which specifications are sent to forest.crumpler@nist.gov are currently on one or more GSA Federal Supply Schedule contracts and, if so, the GSA FSS contract number(s). 5. Any other relevant information that is not listed above which the Government should consider in developing its minimum specifications and finalizing its market research.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/213dfecc6ec74c38ad8c3513789f5df5/view)
 
Place of Performance
Address: Gaithersburg, MD 20899, USA
Zip Code: 20899
Country: USA
 
Record
SN06154971-F 20211010/211008230112 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.