Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JULY 12, 2020 SAM #6800
SOLICITATION NOTICE

N -- Boiler Replacement - Brookings, SD (See Amendment 0001)

Notice Date
7/10/2020 1:54:16 PM
 
Notice Type
Solicitation
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
USDA ARS PA AAO ACQ/PER PROP FORT COLLINS CO 80526 USA
 
ZIP Code
80526
 
Solicitation Number
12805B-20-Q-0056
 
Response Due
7/16/2020 1:30:00 PM
 
Archive Date
07/31/2020
 
Point of Contact
Ed Needens, Phone: 9704927030, Fax: 9704927099
 
E-Mail Address
edward.needens@usda.gov
(edward.needens@usda.gov)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
Update:� 7/10/2020 Added two pictures of the chimney (with text) for clarification.�� ------------------------------------------------- See attached Amendment 0001, Standard Form 30, that�makes the following changes to the original solicitation: (1) Period of Performance changed from 30 Days ARO to 90 Days ARO; (2) Response due date is extended from 7/9/2020 at 2:30 PM MT to 7/16/2020 at 2:30 PM MT; and (3) Section 3C of SOW revised to add ""use double-wall Stainless Steel for the chimney.""� SOW Rev 7-8-20 attached. Please sign and return this form, SF 30, and the original SF 1442 and required documents as your bid. Original Solicatation below: The United States Department of Agriculture (USDA), Agricultural Research Service (ARS), Plains Area Office has a requirement to remove and replace a boiler at the North Central Agricultural Research Laboratory (NCARL), Building 6 for Seed House, Brookings, SD. The existing boiler has reached its expected life and needs replacement. The replacement boiler shall be rated at 900,000 BTU/Hour, 80 percent efficient, with the following dimensions (in inches):� 61 (L) x 30.5 (W) x 66 (H). �The new boiler will pull combustion intake air from inside the room and exit through an 8-inch exhaust.� It shall be a TRIAD steam boiler Series 900 or equivalent. �Piping shall be insulated after leak testing and boiler will be functionality tested to provide the designed amount of steam for building demand. �Contractor will be required to check manufacturer�s requirements, so the amount of the combustion air is adequate for new boiler operation.� Operating gas pressure is field set at startup according to the manufacturer�s requirement. �Contractor shall perform any integration services necessary to insure functionality and compatibility with new equipment. �All work shall adhere to the manufacturer�s guidelines and in accordance with local, state, and federal regulations and codes. The Contractor shall provide all plant, labor, equipment, materials, and transportation, and perform all required work in accordance with the plans and specifications for the removal and replacement.� In accordance with Federal Acquisition Regulation (FAR) 36.204 the magnitude of this construction project is between $25,000 and $100,000.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/e605313ee86c495084495389ca8d67b4/view)
 
Place of Performance
Address: Brookings, SD 57006, USA
Zip Code: 57006
Country: USA
 
Record
SN05717480-F 20200712/200710230156 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.