Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JULY 12, 2020 SAM #6800
SPECIAL NOTICE

71 -- SITE VISIT: Pallet Rack Reconfiguration and Installation Building PH-1392

Notice Date
7/10/2020 10:19:46 AM
 
Notice Type
Special Notice
 
NAICS
332312 — Fabricated Structural Metal Manufacturing
 
Contracting Office
COMMANDING OFFICER PORT HUENEME CA 93043-5007 USA
 
ZIP Code
93043-5007
 
Solicitation Number
N6339420Q0125_FY20-14051
 
Response Due
7/22/2020 3:00:00 PM
 
Archive Date
08/06/2020
 
Point of Contact
Ruben A. Velasquez, Phone: 8052280428
 
E-Mail Address
ruben.velasquez@navy.mil
(ruben.velasquez@navy.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
The Naval Surface Warfare Center, Port Hueneme Division, requires Pallet Rack and Reconfiguration at Naval Base Ventura County Building PH-1392. This requirement will be set-aside for small business. See Note A, below for details about an upcoming site visit. Following a site visit a solicitation my be posted requesting bids to complete the contemplated effort. A draft statement of work is provided below for review. Please sent any questions or comments to ruben.velasquez@navy.mil � � STATEMENT OF WORK BLDG. 1392 Pallet Rack reconfiguration and installation General: The Contractor shall provide all labor, tools, material handling equipment (forklifts, man-lifts, etc), materials, equipment, supervision and services, unless otherwise specified, to complete the work required herein. All the work and procedures shall be performed in conformity to the specifications and work requirements herein. All local labor standards for occupational safety and health apply to this contract. Bidders shall attend a site walk-through/survey to evaluate current configuration and materials that can be reused and take measurements to support preparing proposal. Bidders submittal must include parts list with part numbers, catalog cut sheets, floor and elevation plans. Contractor must request an inspection of work area and hot work permit from NBVC Fire Prevention, (805) 207-3818, prior to conducting any grinding or welding. There is no cost to the contractor for this service. Request 48 hours in advance. Debris Disposal: Debris produced from the work shall be removed and disposed by the contractor. If a dumpster is needed, the contractor must make all provisions for installation, dumping, removal, and clean-up. Scope of work: Summary:� Disassemble, as required, 29 pallet racks, wire decking and vertical wire panels behind racks from 2 areas in the hi-bay and re-use this material as well as furnish additional pallet racks, wire decking, vertical wire panels and posts, and associated hardware to reconfigure and enlarge existing supply and tool cages per the attached new layout drawing.� The vertical wire panels will make an enclosure to prevent unauthorized access to the supply and tool cages. Both the supply and tool cage have sliding, lockable gates with lockable hardware that must be replaced with durable locking and latching hardware to with stand daily use. Tasks: Disassemble nine bays of 108-inch wide pallet racks, wire decking, vertical wire panels behind racks and all associated hardware from southeast side of hi-bay. Save for reuse.� Cut or grind off anchor bolts so they are flush with concrete. Fill any holes with epoxy or other approved suitable, durable substance. Disassemble 20 bays of 96-inch wide pallet racks, wire decking, vertical wire panels behind racks and all associated hardware from southeast side of hi-bay. Save for reuse. Cut or grind off anchor bolts so they are flush with concrete. Install saved (96 & 108 inch wide) pallet racks, wire decking, with vertical wire panels and posts around supply and tool cage along with new material furnished by contractor as required in accordance with provided drawing. �New contractor furnished pallet racks shall be 96 inches wide (interior dimension). Anchor all pallet racks and wire panel posts to the concrete floor. Specifications Anchor all pallet racks and wire panel posts to the concrete floor in accordance with California seismic compliance. All new pallet racks must have a minimum of 6,000 pounds capacity per beam level (3,000 per pallet) with 3 shelves total. No shelf required on floor level. The lowest shelf shall have a minimum 65 inches of clearance to the floor to accommodate 59-inch tall Vidmar cabinet. Other two shelfs shall be set with a minimum 55 inches of clearance between shelves. Vertical wire panels shall be 240 inches tall. New pallet rack uprights shall be a minimum of 216 inches tall. Existing Pallet Racks (all dimensions are in inches): 21 rack bays, 96� (interior) width x 42 deep x 240 tall. Each rack bay has 3 shelves with wire decking. No shelf for floor level. These are marked with �E� on new layout drawing.���� 9 rack bays, 108� (interior) width x 42 deep x 216 tall. Each rack bay has 3 shelves with wire decking. No shelf for floor level. These are marked with �E1� on new layout drawing. New Pallet Racks (all dimensions are in inches): 15 rack bays, 96� (interior) width x 42 deep x 240 tall. Each rack bay has 3 shelves with wire decking. No shelf for floor level. These are marked with �A� on new layout drawing. All vertical dimensions must be taken from the top of slab. The contractor is to verify all location dimensions prior to the start of installation. All frames & post are to be plumb. All bays are to be square. This structure is to be added to an existing building. It is designed as a free standing structure and is not tied to the building except for floor anchors. The ends of the wire panels used to control access to the supply and tool cage can be attached to the walls at the end. Installer is to set up one bay for approval & sign-off by the customer prior to completing installation. Approval & sign-off includes Shims may be used under the base plate to maintain the plumbness of the pallet racks. Shims shall be made of a material that meet or exceeds the design bearing strength or allowable bearing strength of the floor. Shims size and location under base plate shall be equal to or greater than the required base plate size and location. The total thickness of shims shall not exceed 6 times the diameter of the largest anchor bolt. Shims with a total thickness < 6 times the anchor bolt diameter with less than 2 anchor bolts shall be interlocked or welded. Shims with a total thickness < 2 times the anchor bolt diameter need not be interlocked or welded. NOTE A:�� Complete form SITE VISIT REQUEST FORM and send to ruben.velasquez@navy.mil to� be�added�site visit request list by close of announcement�.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/35b2aaa7d5ac4e22a232ba408c4bb889/view)
 
Place of Performance
Address: Port Hueneme CBC Base, CA 93043, USA
Zip Code: 93043
Country: USA
 
Record
SN05717374-F 20200712/200710230155 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.