Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF SEPTEMBER 23, 2019 FBO #6511
SOLICITATION NOTICE

J -- Representative of the Lenel brand in charge of giving Preventive and corrective maintenance to the CCVT, access control and peripheral system located at Namru6 Facilities in Lima and Iquitos, PERU

Notice Date
9/21/2019
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
811213 — Communication Equipment Repair and Maintenance
 
Contracting Office
Department of the Navy, Bureau of Medicine and Surgery, U.S. Naval Medical Research Unit - 6 Peru, Unit 3230 Box 343, American Embassy, DPO AA 34031-0343, Lima, Non-U.S., 34031-0343, Peru
 
ZIP Code
00000
 
Solicitation Number
N44852_FAC191200
 
Archive Date
9/28/2019
 
Point of Contact
Javier B. Gil, Phone: 115116144152
 
E-Mail Address
javier.b.gil.ln@mail.mil
(javier.b.gil.ln@mail.mil)
 
Small Business Set-Aside
N/A
 
Description
Representative of the Lenel brand in charge of giving Preventive and corrective maintenance to the CCVT, access control and peripheral system located at Namru6 Facilities in Lima and Iquitos, PERU - N44852_ FAC191200 Description(s): The Naval Medical Research Unit No. 6 is looking for a supplier and representative of the Lenel brand in charge of giving preventive and corrective maintenance to the CCVT, access control and peripheral system with two biannually visits located at Namru6 Facilities in Lima and Iquitos, PERU. 1. NAMRU-6, LIMA-PERU. 1.1 The access control system counts on 21 doors, composed of electric locks, electric magnets, hydraulic arms, anti-panic bars and sirens, all with the LENEL brand. It also counts with the panel controls inside every building. The SUPPLIER will be in charge of presenting weekly progress to the Supervisor at Namru-6, as well when completing the action plan with: activities done, recommendation, conclusion and a corrective maintenance. Activities undertaken, recommendations, conclusions and to apply corrective support; The SUPPLIER shall submit a report detailing the problem encountered, with a quotation of the solution. 1.2 The CCTV system has a total of 60 cameras, from different manufacturers, TruVision and Axis. It has 2 recorders (XNVR) brand TRUVISION (XNVR1 and XNVR2), accompanied by a main server brand DELL. The SUPPLIER shall submit a weekly report of the activities carried out, a report at the end of the activity carried out detailing the activities carried out, recommendations and, if applicable, corrective support activity, the SUPPLIER shall submit a detailed report of the problem encountered, attaching a quote for the solution. The external chambers are installed at an approximate height of up to 25 meters, for which the SUPPLIER must use an elevator (Manlift) with basket to facilitate maintenance. Scaffolding can be used in places where the elevator cannot be entered (Manlift). The time to respond to an incident in situ, consider the premise that Namru6 specialists coordinate the entrance to facilities. 1.3 The perimeter system has 2 amplifiers, 1 evacuation panel, 1 mixer and sound repeater. As preventive maintenance activities, the following minimum activities should be considered: • General cleaning. • Operation check. The preventive maintenance work will be coordinated with the Namru6 staff and the staff in charge by the SUPPLIER. 2. NAMRU-6, IQUITOS-PERU. 2.1The access control system has 10 doors, which consists of electrical locks, magnetic contacts, entry and exit readers, hydraulic arms, anti-panic bar and sirens, all with the LENEL brand. It also has its control panels inside each building. The SUPPLIER shall submit weekly progress of the activities performed to the Namru-6 Service Supervisor, as well as a report at the completion of detail; Activities undertaken, recommendations, conclusions and to apply corrective support; The SUPPLIER shall submit a report detailing the problem encountered, with a quotation of the solution. 2.2 The CCTV system has a total of 14 cameras, from different manufacturers, Panasonic and Axis. It has a Panasonic brand recorder, accompanied by a client PC. The SUPPLIER shall submit a weekly report of the activities carried out, a report at the end of the activity carried out detailing the activities carried out, recommendations and, if applicable, corrective support activity, the SUPPLIER shall submit a detailed report of the problem encountered, a quote for the solution of the fault. The external cameras are installed at an approximate height of up to 3 meters, for which the SUPPLIER must use scissor ladders or another element to help with the maintenance of the cameras. The time to respond to an incident in situ, consider the premise that Namru-6 specialists coordinate the access to our facilities. The SUPPLIER shall issue a detailed report of the status of the 14 cameras with evidence of a before and after preventive maintenance at the end of each maintenance. Peruvian Local Vendor will also be solicited for this request. Capability statements are due by 12:00 pm Local Eastern Time on September 27, 2019. Capability statements shall be submitted by e-mail ONLY as a Microsoft Word or Adobe PDF attachment to the following address: javier.b.gil.ln@mail; please use subject line "N44852_ FAC191200".
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/8d717d30eea72b2c9fa6722fe1c1f170)
 
Place of Performance
Address: NAVAL MEDICAL RESEARCH UNIT 6, Iquitos and Lima, Peru, Peru
 
Record
SN05453979-W 20190923/190921230037-8d717d30eea72b2c9fa6722fe1c1f170 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.