Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 14, 2019 FBO #6473
SOURCES SOUGHT

D -- 115 FW MXG GPS Repeaters

Notice Date
8/12/2019
 
Notice Type
Synopsis
 
NAICS
517312 — Wireless Telecommunications Carriers (except Satellite)
 
Contracting Office
3110 MITCHELL STREET, BLDG 500 MADISON WI 53704-2591
 
ZIP Code
53704-2591
 
Solicitation Number
W912J2-19-Q-6046
 
Response Due
8/19/2019
 
Point of Contact
Dave W. Mattila, Contract Specialist, Phone 608-245-4788, - Scott E. Homner, Contract Specialist, Phone 608-245-4757
 
E-Mail Address
usaf.wi.115-fw.mbx.fw-contracting@mail.mil, usaf.wi.115-fw.mbx.fw-contracting@mail.mil
 
Small Business Set-Aside
N/A
 
Description
The Government has a requirement to install GPS Repeaters to enable satellite reception inside of maintenance facilities. Work will be accomplished at Truax Field, Madison Wisconsin and is specified herein. The government shall approve of pre-planning, scheduling, on-site investigation of actual conditions, drawings, ordering materials, submissions of persons for Entry Access and like work by the contractor prior to the beginning of the project. Scope of Work 1. The contractor shall ensure GPS signal is attainable via F-16 and F-35 Aircraft from all aircraft parking spots in buildings 400, 406, and 412. This requires the installation of outdoor receive antennas (active) with line of site with overhead satellites. Coaxial cables will run from the receive antennas to interior wall mounted signal controllers to allow the user to precisely control the output level of the signal. The conditioned signal is then ran to the indoor mounted passive antennas. The number of passive antennas mounted in buildings 400, 406, and 412 must be adequate so that all aircraft housed in the buildings are capable of receiving a steady, reliable GPS signal. Lightning/surge protection will be installed to prevent damage to equipment. a. Install active GPS antennas on buildings 400, 406, and 412. i. Antennas must be properly positioned to have sufficient line of sight with satellites. ii. Antennas will be mounted to withstand the following conditions: 1. Basic wind speed (no ice) = 90 MPH 2. Basic wind speed (with ice) = 40 MPH 3. Temperature range = -40C to 40C b. Route coaxial cable from exterior mounted active antennas to interior signal controllers. i. All building penetrations must be approved by the 115th CES. 1. Building penetrations must be sealed after work to prevent travel of air, water, & insects ii. Bend radius of coaxial cable must meet the manufactures specifications. iii. Length of coaxial cable must not exceed GPS equipment manufacture specifications to prevent signal loss. iv. Cable must be affixed to structure and not "free hanging". v. The contractor shall weather proof all outside coaxial cable terminations to prevent corrosion and failures by using cable weather proofing kits. vi. The contractor shall ensure that the coaxial cables have drip loops entering into the building penetration. c. Install signal controllers in buildings 400, 406, and 412. i. Signal controllers must be easily accessible by the user to allow for setting adjustments. ii. Signal controllers must be connected to 110VAC. 1. 110VAC connection source must be approved by 115th CES. iii. Signal controllers will have an automatic control to maintain the set output level regardless of uncertain loss or gain. d. Install passive antennas in buildings 400, 406, and 412. i. Passive antennas will be installed to allow for GPS signal in all aircraft parking spots in buildings 400, 406 and 412. ii. Passive antennas will be mounted to withstand the following conditions 1. Basic wind speed (no ice) = 60 MPH 2. Temperature range = -40C to 40C e. Connect passive antennas to signal controllers. i. If coaxial cable is used to connect the passive antennas to the signal controllers, the following conditions must be met: 1. Length of coaxial cable must not exceed GPS equipment manufacture specifications. 2. Bend radius of coaxial cable must meet manufacturer specifications. 3. Cable must be affixed to structure and not "free hanging". NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (12-AUG-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/spg/USA/NGB/DAHA47-1/W912J2-19-Q-6046/listing.html)
 
Place of Performance
Address: 3110 Mitchell Street Madison, WI
Zip Code: 53704
Country: US
 
Record
SN05401404-F 20190814/190812230014 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.