Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF DECEMBER 21, 2017 FBO #5872
DOCUMENT

65 -- CARDIOSAVE - INTRA-AORTIC BALLOON - Attachment

Notice Date
12/19/2017
 
Notice Type
Attachment
 
NAICS
339113 — Surgical Appliance and Supplies Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 02;1304 Buckley Road;Suite 104;Syracuse NY 13212
 
ZIP Code
13212
 
Solicitation Number
9234
 
Response Due
12/22/2017
 
Archive Date
2/20/2018
 
Point of Contact
Denise Edmonds
 
E-Mail Address
Purchasing Agent
(Denise.Edmonds@va.gov)
 
Small Business Set-Aside
N/A
 
Description
This is Sources Sought announcement only this is not a Request for Quote. The purpose of this notice is to conduct market research and obtain information from qualified vendors with special interest. No solicitation is being issued at this time. This notice shall not be construed as a commitment by the Government to ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. All information submitted in response to this announcement is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government. The appropriate NAICS Code is 339113 Surgical Appliance & Supplies Manufacturing The U.S. Department of Veterans Affairs, Network Contracting Office 2, and the VA Medical Center in Syracuse, NY anticipate a purchase order for the following: MFG - Maquet 0998-00-0800-53 CARDIOSAVE Hybrid and one (1) year warranty Product includes CARDIOSAVE Blood Pressure Transducer Adapter Cable CARDIOSAVE ECG Trunk Cable 5 lead AAMI CARDIOSAVE ESIS Lead Wires 50" 5 Lead (Op Rm) - AAMI Helium 3 refillable tanks, 104L Ex Available 24/7 Remote Support via Win-IABP Initial Clinical Education on IABP 24 Hour Clinical Support 2 Each ZSUSGDCSVEW5 CARDIOSAVE MCare Gold Pin POSEW5Y 2 Each 0998-00-0803 CARDIOSAVE Trainer 2 Each Required Salient Characteristics A transport modality which decreases the units weight from 114lbs to 53lbs for transporting of the patient. This allows for easier movement of patient between units and onto ambulances or airtransport for hospital to hospital movement. Less weight also means lower risk of staff back or other injury. A one button start with no warm up period or manuel zeroing required which decreases time to start therapy and minutes matter in the situations this will be used. Automatic condensation removal. Other systems have a liquid collection jar that must be manually emptied. 3 hour Lithium ion batteries which are hot swappable meaning they can be changed out without shutting the unit down or plugging it in during transport. An auto-lock screen feature which automatically locks the screen after 2 minutes, preventing accidental changing of settings which could be devastating. Cardiosave performs an in-vivo calibrationthat is an indepth zeroing process which takes place inside the patients body. This is done on start up and every 2 hours and on change in patient condition. Other units do not perform any repeat calibration at all. Cardiosave uses a scroll compressor which has faster inflate/deflate times. This allows for motor speed to be controlled based on the demand of the patients heart; it ramps its rate up and down based on changes in heart rate. Competition has speed delays because of older bellows technology. Cardiosave automatically replaces helium lost from diffusion. This procurement is for new items only; no remanufactured or "gray market" items. FOB - destination Interested vendors are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the System for Award Management (SAM) database prior to award of a contract. Responses should address how you will meet the Government's needs and provide a brief capability statement. All vendors that are interested in meeting this requirement are asked to submit the following information as well: 1) Company Name: 2) Company Address: 3) DUNS Number: 4) Company POC Name: 5) Company POC Phone: 6) Company POC Email: 7) Business type: (Large, Small, Woman-Owned, VOSB/SDVOSB, etc.): Please identify your company's small business size standard and applicable NAICS code. For more information refer to http://www.sba.gov/content/table-small-business-size-standards. Note: If claiming SDVOSB or VOSB, the firm must be registered and CVE verified in VetBiz Registry http://www.vetbiz.gov/; also include VetBiz certification. (Non-Manufacturer rules apply) A formal RFQ may be issued upon receipt of information pertaining to this Sources Sought Notice. If you are capable of meeting the requirement, please send your responses via email NLT 2:00pm on Thursday, December 22, 2017 to Denise Edmonds, Purchasing Agent, at Denise.Edmonds@va.gov DO NOT SEND QUOTES AT THIS TIME
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/SyVAMC670/SyVAMC670/9234/listing.html)
 
Document(s)
Attachment
 
File Name: 9234 9234.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3973921&FileName=9234-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3973921&FileName=9234-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Syracuse VA Medicalk Center;800 Irving Avenue;Syracuse, NY
Zip Code: 13210
 
Record
SN04770993-W 20171221/171219231236-eeab40685c0ecb6192aca9956019f745 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.