Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF SEPTEMBER 17, 2017 FBO #5777
MODIFICATION

Z -- Pure and Ultra-Pure Water System PM & Repair

Notice Date
9/15/2017
 
Notice Type
Modification/Amendment
 
NAICS
811219 — Other Electronic and Precision Equipment Repair and Maintenance
 
Contracting Office
Department of Commerce, National Institute of Standards and Technology (NIST), Acquisition Management Division, 100 Bureau Drive, Building 301, Room B130, Gaithersburg, Maryland, 20899-1410, United States
 
ZIP Code
20899-1410
 
Solicitation Number
SB1341-17-RP-0041
 
Archive Date
10/3/2017
 
Point of Contact
Patricia M. Bullington, Phone: 3034973106
 
E-Mail Address
patricia.bullington@nist.gov
(patricia.bullington@nist.gov)
 
Small Business Set-Aside
N/A
 
Description
Amendment 1 is to provide Questions and Answers to RFP: SB1341-17-RP-0041 Pure & Ultra-Pure Water Systems Maintenance & Repairs. The proposal due date remains unchanged. 1. We want to confirm that the proposal should not include the ozone disinfection. It is our understanding from the SOW that the ozone will be negotiated after the contract has been awarded. Response: 1. Only the level of ozone(i.e.. how many parts per million) will be negotiated after award. The cost of ozone generation and method of introducing ozone into the system should be in your proposal. Disinfect the entire PW system (distribution loop lines plus a 2200 gallon storage tank) using a level of ozone negotiated after award of contract based on contractors ozone generation method and NIST system requirements. The contractor shall supply a method of generating ozone to properly disinfect the PW system to a level that meets or exceeds the CAP Type II (Resistivity: 2 MOhm/cm @ 25 C): College of American Pathologists Standards. NIST does not have the capability to generate ozone. After disinfection, the PW system must generate 14 gpm of purified water that meets or exceeds the CAP Type II (Resistivity: 2 MOhm/cm @ 25 C): College of American Pathologists Standards. Disinfect the entire UPW system (distribution loop lines plus a 2200 gallon storage tank) using a level of ozone negotiated after award of contract based on contractors ozone generation method and NIST system requirements. The contractor shall supply a method of generating ozone to properly disinfect the PW system to a level that meets or exceeds the Electronic Type E-1 (Resistivity 18.1 MOhm/cm @ 25 C, without dissolved oxygen requirements): ASTM D-5127 standard. NIST does not have the capability to generate ozone. After disinfection, the UPW system must generate 30 gpm of purified water that meets or exceeds the Electronic Type E-1 (Resistivity 18.1 MOhm/cm @ 25 C, without dissolved oxygen requirements): ASTM D-5127 standard. 2. Concerning the weekend work. Will our staff have access to the areas we need to work for the entire weekend so that we can come and go as needed? Response: 2. You will have the opportunity after award to have employees hard badged and those employees will have 24/7 access to the pure water system. There will also be a COR or POC on site during the weekend activities. 3. Does the Combined Synopsis/Solicitation under solicitation number SB134117RP0041 contain requirements similar to a current contract? If possible, please provide the current contract number. Or, is this a new requirement for the government? Response: 3. Yes, the solicitation contains requirements similar to the current contract. The current contract is being performed under SB1341-14-SE-0392. Although the scope has changed, it is not a new requirement for the Government.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOC/NIST/AcAsD/SB1341-17-RP-0041/listing.html)
 
Place of Performance
Address: Department of Commerce, National Institute of Standards and Technology, 325 Broadway, Building 81, Boulder, Colorado, 80305-3328, United States
Zip Code: 80305-3328
 
Record
SN04679572-W 20170917/170915231310-e76f153b4bc919c433620d1f59959054 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |