Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JULY 08, 2017 FBO #5706
DOCUMENT

65 -- 564-17-3-082-0507 - Electric zoom stretcher - VA256-17-AP-8168 - Attachment

Notice Date
7/6/2017
 
Notice Type
Attachment
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
ALEXANDRIA VA HEALTH CARE SYSTEM;NETWORK CONTRACTING OFFICE 16;ALEXANDRIA VA HEALTH CARE SYSTEM;PO BOX 69004;ALEXANDRIA LA 71306-9004
 
ZIP Code
71306-9004
 
Solicitation Number
VA25617Q1037
 
Response Due
7/21/2017
 
Archive Date
8/20/2017
 
Point of Contact
Renata Ott
 
E-Mail Address
6-2241<br
 
Small Business Set-Aside
N/A
 
Description
General Requirements The entire Hospital Grade Stretcher and Mattresses shall be provided by the vendor (and/or the vendor s sub-contractor). The quoted shall include all equipment, materials, installation services, and training services specified in this Statement of Work (SOW) document. In addition, the vendor shall provide a stretcher system (defined as frame, mattress, side rails, and any mattress or accessories added to the stretcher), which demonstrate compliance to all aspects of the International Standard IEC 60601-2-52 as it relates to medical grade stretchers. Item offered must meet minimum salient characteristics of items described within the Schedule of Items. Offeror to provide technical brochures to support functionality features as described within the Schedule of Items with the exact item offered. In addition, Electronic data or virtual link in order to examine capabilities shall be provided. Offerors shall provide in detail for each feature that is required whether or not that particular specification is or is not offered with a reference to the quote/brochure/data provided. Offeror shall also provide evidence of being an Authorized Reseller (Distributor) for product offered. This can be substantiated with a link to Manufacturer s web site that supports offeror s distributorship or other proof from the manufacturer. Quantity: Medical Grade Stretchers =12 Mattresses = 12 each Delivery and Installation Services Materials provided shall be new equipment, parts, and accessories as specified in the SOW. The vendor shall deliver materials to the job site in OEM's original unopened containers, clearly labeled with the OEM's name, equipment model and serial identification numbers, and Purchase Order (PO) number. The vendor is responsible for inventorying materials prior to delivery to VHSO to check for accuracy in quantity and part number. All on-site installation services shall be provided by vendor. Disposal of Waste Technical Support Response time for parts and labor will be no more than 24 hours available 24/7 Facility Engineering Technical Training Vendor shall provide any special service tools and/or test equipment comparable with that provided to the OEM s service personnel Service and Operator Manuals The vendor shall provide the following documentation for the proposed stretcher system: Two copies of the operator s manual Two copies of complete technical service manuals including troubleshooting guides, necessary diagnostic software and equipment, schematic diagrams, and parts lists Electronic versions of both operators manual and technical service manuals Abbreviated operating instructions should be included on all stretchers. DVD or web based training for both operator s manual and service if available. The operator s manual must specify the mattress size to reduce risk of patient entrapment between stretcher and side rail. On-Site User Training Specific Stretcher Requirements Requirements Description Construction Quality The equipment should be simple to use, operate, and maintain. The equipment should be well constructed with durable materials to withstand typical abuse and cleaning. The equipment should have no sharp edges. All external components should be securely mounted. The equipment should provide adequate protection against moving and electrically energized parts. The equipment should be designed to provide easy access to serviceable parts. Switches, knobs, and other controls should be designed for conditions of heavy use. Cord connections should be secure to resist accidental disconnection Labels and markings should be clear, legible, and durable enough to withstand routine cleaning and normal wear. Appropriate warning labels should be provided on the equipment. Overall Dimensions Total stretcher dimensions: Width with side rails up must not exceed 37 Length fully retracted must not exceed 74 500-800 pound weight capacity Standard patient surface (max 30 wide), (minimum 74.25 long) Positioning Features All positioning features must be electric and available with battery back-up Trendelenburg/Reverse Trendelenburg: (Minimum 150/100 with visible gauge to indicate degree of angle) Max backrest elevation 0-90 degrees Knee gatch must be a pneumatic lever for easy manipulation and a one touch release that is recessed into the frame of the stretcher. Manual CPR release Head of Bed must raise and lower with one-handed release from either side of stretcher The vendor shall provide mounting points and/or retrofit kits compatible with VHSOs current call light system. Controls The controls (e.g., switches, knobs) visible and clearly identified and their function self-evident (control design should prevent misinterpretation of displays and control settings). Switches and controls protected against accidental setting changes. Controls sealed against penetration of liquids. Side Rails Locking mechanism must stand a 30,000 cycle test up and down. Side rails raise and lower easily, tuck completely under the stretcher to create a 0 gap for transfer utilizing a one step process Casters & Brakes 8 Casters All casters are controlled by central locking system. Casters may be set in steer, neutral, and locked positions Brakes easy to apply from either end Electrical Requirements The stretcher shall operate on regular 110 VAC medical provided power, and connect to standard electrical receptacles. Cord storage for transport Battery The stretcher shall provide battery back-up function to control stretcher height (if not able to do so manually), position (head up and down), and length in the event of power failure. Battery back-up must engage automatically or be easily labeled and accessible A fully charged battery should last 2 hour minimum Accessories Accessories will not interfere with current equipment in rooms including ceiling lifts Stretchers should come with the following accessories : Litter mounted Oxygen Tank Holders (E size tank) IV Poles Collapsible or Stowable with the ability to fold it down and store in the down position. If removable there needs to be a place on the stretcher to store the IV pole. Hand control for patient positioning Built in scale and weight sensitive alarm RME Infection Control The vendor shall provide training and written instructions, procedures, and documentation necessary to properly and safely disinfect the equipment and accessories between patient uses. The stretcher frame must be constructed to prevent fluids from entering mechanical areas. Warranty The vendor shall provide details of standard warranty. Specific Mattress Specifications Requirements Description Mattress Features The vendor must provide a mattress that meets all of the following features: Mattress must be latex free The mattress cover must meet the following features: Allow for partial immersion into foam stain resistant mildew resistant flame retardant designed to reduce the risk of friction and/or sheer forces during repositioning with a low friction fabric meets infection control guidelines of water proofing (prevents contamination of foam), welded seams (prevent ingress of fluids), waterfall flaps (cover over zippers) must not degrade with the use of standard hospital grade disinfectants Mattress dimensions: 5 thick (vii) Delivery FOB Destination to Department of Veterans Affairs Healthcare System, 1100 n. College Ave, Fayetteville AR 72703 within 90 days from time of award.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/AlVAMC502/AlVAMC502/VA25617Q1037/listing.html)
 
Document(s)
Attachment
 
File Name: VA256-17-Q-1037 VA256-17-Q-1037_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3641229&FileName=VA256-17-Q-1037-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3641229&FileName=VA256-17-Q-1037-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN04568559-W 20170708/170706234529-79ca76c4ffef92a2964495a3e0a40b59 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.