DOCUMENT
65 -- Zeiss Pro Forum and Archive and Viewer - Attachment
- Notice Date
- 6/16/2017
- Notice Type
- Attachment
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office 4;Acquisition (90C);1010 Delafield Road;Pittsburgh, PA 15215
- ZIP Code
- 15215
- Solicitation Number
- VA24417Q0929
- Archive Date
- 6/18/2017
- Point of Contact
- donna.cooper2@va.gov
- E-Mail Address
-
Donna.Cooper2@va.gov
(Donna.Cooper2@va.gov)
- Small Business Set-Aside
- N/A
- Description
- Intent to Sole Source to ProAim Americas, LLC for Forum Data Management. This software package will be used in the optometry department to electronically tie different pieces of medical equipment together. It will enable the optometry department to import and export information to VistA and CPRS. This will also allow other facilities to be able to view testing data that has been done at other facilities. The equipment to be used with FORUM are Humphries Visual Fields HFA3 Field analyzer, Cirrus Photo 800 OCT, Optos California, Sonomed B scan ultrasound, Topcon KR-1W autorefractor, Zeiss 120 slit lamp 5.0 Camera. Brief Statement of Work: Image and Data Management System must be FDA 510k approved and listed as a Medical Device. Image and Data Management System must provide Post Processing Analysis, Dynamic Review/Manipulation of RAW data functionality for ZEISS Cirrus HD-OCT. If Glaucoma Workplace is procured you can do with the ZEISS HFA Instruments as well. Image and Data Management System must be able to store and access raw instrument data from ZEISS Field Analyzer, ZEISS Cirrus HD-OCT, ZEISS Visucam Fundus Camera and ZEISS FF450/Visupac Fundus Camera systems. Image and Data Management System must have functionality to enable real-time and dynamic editing/manipulation of all prior Visual Field Test data for all Glaucoma patients and allow for Baseline changes, real-time report generation for any VFI date, display RealEye images and data from the new ZEISS HFA 3 instruments. Image and Data Management System must support DICOM standards and Work-List functionality in order to create and send patient demographics to a specific or all instrument s via a DICOM work-list within the eye clinic s network. Combined Report: HFA-Cirrus reports for Structure Function analyses in Single Display with OD-OS on one (1) page print out from data of Cirrus HD OCT and a Humphrey Visucal Field. If Combined Report is procured as option of FORUM. Image and Data Management System must have Bi-directional DICOM capabilities to send both DICOM Modality Work-lists containing Consult/Order details to instrument s within the eye-clinics network and receive back the diagnostic test results and RAW data for storage within the Image and Data Management System for access. Image and Data Management System must connect to any brand of non-DICOM diagnostic instrument with export capabilities, and convert the diagnostic test results into a DICOM compatible file containing all patient demographical information, UID s, Accession number, Device name and type, laterality and other key pieces of data with the least amount of user interaction. This must be then stored within the Image and Data Management System and also forwarded to the NAVY ECIA (Enterprise Clinical Imaging Archive) Image and Data Management System must not require the use of an external PC or import computer for a DICOM compatible modality. Image and Data Management System must be able to download all past RAW data from one or more ZEISS Field Analyzers, ZEISS Cirrus HD-OCT s, ZEISS Visucam Fundus Camera and ZEISS FF450/Visupac Fundus Cameras acquired within the main clinic and all satellite clinics upon installation of the Image and Data Management System. Image and Data Management System must be able to display ZEISS Field Analyzer Glaucoma Progression Analysis (GPA) and enable the clinician to manipulate data and store baseline changes at the workstation within the Image and Data Management System if Glaucoma Workplace is procured as a part of FORUM Image and Data Management System must be able to display and allow the clinician to scroll through the various ZEISS Cirrus Macula Cube B-scan slices, within in the Image and Data Management System viewer. Image and Data Management System must be able to display images in pre-formatted clinical display groupings for Glaucoma, Retina and Cataract cases. Vendor will allow the installation of the full set of VA security software to be installed on the server.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/PiVAMC646/PiVAMC646/VA24417Q0929/listing.html)
- Document(s)
- Attachment
- File Name: VA244-17-Q-0929 VA244-17-Q-0929_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3589169&FileName=VA244-17-Q-0929-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3589169&FileName=VA244-17-Q-0929-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA244-17-Q-0929 VA244-17-Q-0929_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3589169&FileName=VA244-17-Q-0929-000.docx)
- Record
- SN04548512-W 20170618/170616235452-749a914bc14062e08f80aec1bbecc937 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |