Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF DECEMBER 16, 2016 FBO #5502
DOCUMENT

J -- Replace Two Heat Exchange Bundles at the Roseburg VA Medical Center 913 NW Garden Valley Blvd Roseburg OR, 97471 - Attachment

Notice Date
12/14/2016
 
Notice Type
Attachment
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 20;5115 NE 82nd Ave, Suite 102;Vancouver WA 98662
 
ZIP Code
98662
 
Solicitation Number
VA26017Q0096
 
Response Due
12/23/2016
 
Archive Date
1/22/2017
 
Point of Contact
POC at VA facility is Curt Gerritsen
 
E-Mail Address
0-1000
 
Small Business Set-Aside
N/A
 
Description
Roseburg VA Facility Building 1, Heat Exchanger Equip purchase Statement of Work Contractor to provide heat exchanger with incidental installation included located in Building 1, rooms E144 and E128 further detailed below. The contractor shall conduct functional testing to confirm proper installation and operation. The contractor will dispose of all equipment components demolished or replaced as part of this project. Project Duration: Project is to take no longer than 120 calendar days from notice to proceed. Bldg. 1, Utility room E144 : The work shall include: Disconnect and demo the (2) existing heat exchangers and associated piping Provide (2) JFD 12 x 36, 4 pass heat exchangers and associated piping / fittings and Appurtenances. Re-insulate heat exchangers and all associated components, fittings and piping Provide start-up and testing required Salient Characteristics: Shell Side MAWP= 150 psi @ 375 °F MDMT= -20 ° F @ 150 psi Tube Side MAWP= 125 psi @ 375 ° F MDMT= -20 ° F @ 125 psi Bldg. 1, Utility room E128 : The work shall include: Disconnect and demo the (1) existing heat exchangers and associated piping Provide (1) JFD 12 x 36, 2 pass heat exchangers and associated piping / fittings and Appurtenances. Re-insulate heat exchangers and all associated components, fittings and piping Provide start-up and testing required Salient Characteristics: Shell Side MAWP= 150 psi @ 375 °F MDMT= -20 ° F @ 150 psi Tube Side MAWP= 150 psi @ 375 ° F
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/24bcf5a0fd4863af45b0adaa4bcd16c1)
 
Document(s)
Attachment
 
File Name: VA260-17-Q-0096 VA260-17-Q-0096.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3162007&FileName=VA260-17-Q-0096-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3162007&FileName=VA260-17-Q-0096-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN04351011-W 20161216/161214233906-24bcf5a0fd4863af45b0adaa4bcd16c1 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.