Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF SEPTEMBER 17, 2016 FBO #5412
DOCUMENT

J -- UPS/COMMUNICATIONS SYSTEM MAINTENANCE AGREEMENT FOR ST PAUL RO (335) - Attachment

Notice Date
9/15/2016
 
Notice Type
Attachment
 
NAICS
811212 — Computer and Office Machine Repair and Maintenance
 
Contracting Office
Department of Veterans Affairs;Veterans Benefits Administration;Office of Acquisition;1800 G. Street N.W.;Washington DC 20006
 
ZIP Code
20006
 
Solicitation Number
VA101V16Q0443
 
Response Due
9/18/2016
 
Archive Date
12/14/2016
 
Point of Contact
John A Player
 
E-Mail Address
3-1987<br
 
Small Business Set-Aside
N/A
 
Description
A.The amendment to combined synopsis solicitation VA101V-16-Q-0443 is written to change paragraph vi., Description of Requirement. B.On paragraph vi., subparagraph 3.0 - Scope of Work, A. MDF/Server Room, Product Description, remove the text that reads "StruxureWare Central Basic" this deletion applies to all equipment listed in Appendix B of the Scope of Work, including any Software Support Contracts. The deletions effected are shown in the revised scope of work that is attached to this amendment. C.The date and time set for receipt of quotes is not changed by this amendment and remains September 19, 2016 by 2:00PM Central Time. D.All other terms and conditions of this solicitation remain the same. STATEMENT OF WORK (SOW) FOR UPS System Maintenance 1.0- Introduction The Bishop Henry Whipple (BHW) Federal Building hosts the St. Paul VA Regional Office. In support of OI&T's mission to support continuous and secure IT support to VA customers, Uninterruptable Power Supplies (UPS) are required at all VA installations. This Statement of Work (SOW) outlines a new contract to service and maintain the UPS equipment and peripheral UPS and related equipment in the VA spaces (MDF + 21 IDF) of the Bishop Henry Whipple Federal Building location. 2.0- Background Maintaining a UPS is an important component of overall network security and support. This contract is needed to ensure network security and stability in case of emergency. 3.0- Scope of Work The Contractor shall provide maintenance services per the readily available COTS (Commercial Off The Shelf) part numbers listed below and in the Appendix A, at the locations shown: Installed Site: Department of Veterans Affairs Bishop Henry Whipple Federal Bldg. 1 Federal Drive Saint Paul, MN 55111 A.MDF/Server room - Overview (See Appendix A for detailed list) Humidifier: SK3044MSD4 SN 120 239999 Product DescriptionProduct Preventive?Maintenance?Visit?5X8 Symmetra UnitIntelligence Module (x2) Power Module (x4) System Power Supply Static Switch Battery Unit (4x4) Sensor/pod/camera packagesTypeModel Sensor PodSensor Pod 150 Integrated NetBotz Wall Appliance device 1NetBotz Wall Monitor 355 NetBotz Wall Appliance device 2NetBotz Wall Monitor 355 Camera PodCamera Pod 160 B.IDF/Switch Closets: - Overview (See Appendix A for detailed list) APC UPS SMSX3000RMLV2U and the UPS sensor/pod/camera: TypeModel Sensor PodSensor Pod 150 Integrated NetBotz Wall Appliance device 1NetBotz Wall Monitor 355 NetBotz Wall Appliance device 2NetBotz Wall Monitor 355 Camera PodCamera Pod 160 C.Preventative Maintenance Visits The contractor shall provide all parts, labor and travel related to each preventative maintenance visit. The contractor shall perform all preventative maintenance inspections and services during normal working hours Mon-Fri (5x8). General Tasks to Be Performed For Each Inspection: -Perform Visual Inspection -Perform Environmental Inspection -Perform Mechanical/Electrical Inspection -Verify firmware revision and update as needed -Deliver Site Report with service recommendations D.On-Site Service The contractor shall provide on-site services in the event of equipment failure under this contract. Guaranteed response time is next business day. The contractor shall performed the following: -Check system status -Check system alarm -Troubleshoot reported issue and diagnose problem -Repair system as required -Complete functional tests after repair -Deliver detailed report of action taken -Implement firmware update as needed E.Remote Monitoring Service The contractor shall provide remote monitoring. Monitoring shall include, but is not limited to the following: -Collect and document pertinent system information -24 x 7 system monitoring -Notify and dispatch field engineer as needed -Monthly report identifying potential problems and recommendations F.Tech Support The contractor shall provide technical support including escalation support to address system issues in a timely and efficient manner. G.Parts (Exception: Batteries) The contractor shall furnish all parts, labor, and travel required for both the Preventative Maintenance and On-Site Service under this contract. 4.0- Applicable Directives The Contractor will not have network access. The Contractor shall comply with all security requirements imposed by the installation commander at all times while on the installation. Contractor personnel involved in civil crimes and/or other incidents of misconduct may be restricted from entry onto the installation. No other specific directives apply. See Attached equipment Checklist Appendix A See Attached equipment Hardware Serial Number list Appendix B 5.0- Performance Requirements Place of performance: Bishop Henry Whipple (BHW) Federal Building: 1 Federal Drive, St. Paul, MN 55111-4050 MDF: Rm 3900 IDF: Varied Service appointments shall be conducted during the normal business hours of Monday through Friday (6:30 A.M. - 5:30 P.M.) unless otherwise arranged due to emergency and/or service upgrades contracted. The St. Paul RO shall not incur any charges for appointments cancelled by the Contractor. 6.0- Billing The Contractor will provide the NSC and Finance Departments with an invoice of service to include: 1.Contract Number 2.Company Name and Address 3.Invoice Date 4.Invoice Number (Note: Each invoice must have a different Invoice Number). 5.Description of items/services provided as well as referencing the appropriate Contract Line Item Number (CLIN). This way the proper CLIN can be billed for the Invoice. 6.Terms for any discount for prompt payment. 7.Name, title and phone number of company point of contact to notify in case of a defective invoice. 7.0- Point of Contact Name: Damian Zebrosky Phone: (612) 970-5228 Fax: (612) 970-5244 E-Mail: Damian.Zebrosky@va.gov 8.0- Holidays The contractor will not be required to perform any work for the government on any of the following federal holidays: New Year's Day, Martin Luther King Jr's Birthday, Washington's Birthday, Memorial Day, Independence Day, Labor Day, Columbus Day, Veterans' Day, Thanksgiving Day, and Christmas Day. 9.0- Service Contract Labor Wages This contract incorporates the wages and fringe benefits of the following wage determinations Wage DeterminationOccupation Wage (Including Fringe Benefits) 05-2287, Revision 17Electronic Technician, Maintenance II$30.33 The contractor shall pay each employee that performs work under this contract at least the wages and fringe benefits indicated on the Wage Determination and the table above. The Government may require submission of payrolls, conduct labor interviews, or perform other investigations to determine that clients are receiving the wages and fringe benefits required under this contract. 10.0 - Superintendence of Contractor The contractor shall, at all times and while work is being performed under this contractor, provide supervision and superintendence of workers under this contract. The contractor shall also provide superintendence of all prime and subcontractor work performed, regardless of whether or not the subcontractor is providing his or her own superintendence. 11.0- Superintendence of Contractor Any changes to this SOW shall be authorized and approved only through written correspondence from the Contracting Officer. A copy of each change will be kept in a project folder along with all other products of the project. Costs incurred by the contractor through the actions of parties other than the Contracting Officer shall be borne by the contractor. 12.0- Confidentiality and Non-Disclosure 1.The preliminary and final deliverables and all associated working papers, application source code, and other material deemed relevant by VA which have been generated by the contractor in the performance of this task order are the exclusive property of the U.S. Government and shall be submitted to the Contracting Officer at the conclusion of the task order. 2.The Contracting Officer will be the sole authorized official to release verbally or in writing, any data, the draft deliverables, the final deliverables, or any other written or printed materials pertaining to this task order. No information shall be released by the contractor. Any request for information relating to this task order presented to the contractor shall be submitted to the Contracting Officer for response. 3.Press releases, marketing material or any other printed or electronic documentation related to this project, shall not be publicized without the written approval of the Contracting Officer. 13.0- Contract Security Requirements The C&A requirements do not apply to this contract. A security accreditation package is not required. Contractor personnel will be escorted at all times by Department of Veterans Affairs personnel while performing any work in the St. Paul Regional Office. ? APPENDIX A EQUIPMENT LIST 1.MDF - Server Room contents ( MAIN -power load, APC UPS and UPS sensors/pod/camera): TypeModelSerial Number Camera PodCamera Pod 160CAMERA_00:C0:B7:92:F1:F7 Camera PodCamera Pod 160QA1202180746 Camera PodCamera Pod 160CAMERA_00:C0:B7:92:F1:F4 Camera PodCamera Pod 160QA1203180509 Camera PodCamera Pod 160CAMERA_00:C0:B7:92:F1:FE Camera PodCamera Pod 160QA1151180740 Camera PodCamera Pod 160CAMERA_00:C0:B7:9D:7D:00 Camera PodCamera Pod 160CAMERA_00:C0:B7:92:F1:ED Camera PodCamera Pod 160CAMERA_00:C0:B7:92:DD:6F Camera PodCamera Pod 160CAMERA_00:C0:B7:92:F2:05 Cooling DeviceInRow RD 10KW Water/Glycol Cooled 60HzJK1149012831 Cooling DeviceInRow RD 10KW Water/Glycol Cooled 60HzJK1149012829 Cooling DeviceInRow RD 10KW Water/Glycol Cooled 60HzJK1143000007 Cooling DeviceInRow RD 10KW Water/Glycol Cooled 60HzJK1149012827 Cooling DeviceInRow RD 10KW Water/Glycol Cooled 60HzJK1143000002 Cooling DeviceInRow RD 10KW Water/Glycol Cooled 60HzJK1149012834 NetBotz Rack ApplianceNetBotz Rack Monitor 550QA1223180220 NetBotz Rack ApplianceNetBotz Rack Monitor 550QA1223180220 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180314 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180314 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180290 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180304 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180298 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180300 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180304 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1150180148 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180300 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180290 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1249180185 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180298 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1150180148 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1249180185 PDU0M-5103PI1145310764 Rack PDUAP7862ZA1133011613 Rack PDUAP7863ZA1143024420 Rack PDUAP7894ZA0947003890 Rack PDUAP7862ZA1133011617 Rack PDUAP7863ZA1143024395 Rack PDUAP7862ZA1133011607 Rack PDUAP7863ZA1143024412 Rack PDUAP7862ZA1133011612 Rack PDUAP7894ZA0947003891 Rack PDUAP7863ZA1143024419 Rack PDUAP78625A1143E01058 Rack PDUAP7863ZA1143024405 Rack PDUAP7862ZA1133011619 Rack PDUAP7862ZA1133011608 Rack PDUAP7863ZA1143024429 Rack PDUAP7863ZA1146019211 Rack PDUAP7863ZA1143024417 Rack PDUAP7863ZA1143024396 Rack PDUAP7862ZA1133011610 Rack PDUAP7862ZA1133011605 Rack PDUAP7863ZA1143024418 Rack PDUAP7862ZA1133011604 Rack PDUAP78625A1143E01045 Rack PDUAP78625A1143E00979 Rack PDUAP7863ZA1146019201 Rack PDUAP7863ZA1146019217 Rack PDUAP7863ZA1146019210 Rack PDUAP7862ZA1133011611 Sensor PodSensor Pod 150 IntegratedQA1150180148 Sensor PodSensor Pod 150 IntegratedQA1203180290 Sensor PodSensor Pod 150 IntegratedQA1203180304 Sensor PodSensor Pod 150 IntegratedQA1203180298 Sensor PodSensor Pod 150 IntegratedQA1203180314 Sensor PodSensor Pod 150 IntegratedQA1249180185 Sensor PodSensor Pod 150 ExternalZA1146023031 Sensor PodSensor Pod 150 IntegratedQA1223180220 Sensor PodSensor Pod 150 IntegratedQA1203180300 SK304MSD4Humidifer120?23999 UPSSymmetra 40KPD1204150024 ? 2.IDF closet contents (APC UPS Model SMX3000RMLV2U and UPS sensors/pod/camera) - quantity 20 1.20 (qty) APC UPS SMX3000RMLV2U Smart UPS Serial Numbers IS1129000980 IS1129000978 IS1129004692 IS1129000986 IS1129000976 IS1129000982 IS1129000972 IS1312004056 IS1129004696 IS1129004691 IS1129004697 IS1220004381 IS1129004634 IS1129004702 IS1312002588 IS1312002589 IS1312002587 IS1303000709 IS1303000717 IS1303000716 2.20 (qty) sensor/pod/camera assembly: TypeModelSerial Number Camera PodCamera Pod 160CAMERA_00:C0:B7:9D:7C:F4 Camera PodCamera Pod 160CAMERA_00:C0:B7:92:F2:00 Camera PodCamera Pod 160CAMERA_00:C0:B7:9D:7C:EE Camera PodCamera Pod 160CAMERA_00:C0:B7:92:F2:28 Camera PodCamera Pod 160CAMERA_00:C0:B7:92:F1:FE Camera PodCamera Pod 160CAMERA_00:C0:B7:92:F1:F7 Camera PodCamera Pod 160CAMERA_00:C0:B7:9D:7D:00 Camera PodCamera Pod 160CAMERA_00:C0:B7:92:F2:05 Camera PodCamera Pod 160CAMERA_00:C0:B7:92:F1:FB Camera PodCamera Pod 160CAMERA_00:C0:B7:92:F2:45 Camera PodCamera Pod 160CAMERA_00:C0:B7:92:F2:1A Camera PodCamera Pod 160CAMERA_00:C0:B7:9D:7D:13 Camera PodCamera Pod 160CAMERA_00:C0:B7:92:F1 Camera PodCamera Pod 160CAMERA_00:C0:B7:92: Camera PodCamera Pod 160CAMERA_00:C0:B7:92: Camera PodCamera Pod 160CAMERA_00:C0:B7:92:F2 Camera PodCamera Pod 160CAMERA_00:C0:B7:92:F1 Camera PodCamera Pod 160CAMERA_00:C0:B7:92:F1 Camera PodCamera Pod 160CAMERA_00:C0:B7:9D: Camera PodCamera Pod 160CAMERA_00:C0:B7:9C: NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1249180178 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1249180178 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180309 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180309 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1249180136 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1249180136 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180349 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180349 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180304 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180304 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180300 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180300 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1249180185 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1249180185 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180314 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180314 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180307 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180307 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180378 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180378 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180335 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180335 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1249180198 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1249180198 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180290 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180290 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1150180148 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1150180148 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180316 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180316 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180386 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180386 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180291 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180291 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180298 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1203180298 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1249180291 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1249180291 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1242180266 NetBotz Wall ApplianceNetBotz Wall Monitor 355QA1242180266 Sensor PodSensor Pod 150 IntegratedQA1249180178 Sensor PodSensor Pod 150 IntegratedQA1203180309 Sensor PodSensor Pod 150 IntegratedQA1249180136 Sensor PodSensor Pod 150 IntegratedQA1203180349 Sensor PodSensor Pod 150 IntegratedQA1203180304 Sensor PodSensor Pod 150 IntegratedQA1203180300 Sensor PodSensor Pod 150 IntegratedQA1249180185 Sensor PodSensor Pod 150 IntegratedQA1203180314 Sensor PodSensor Pod 150 IntegratedQA1203180307 Sensor PodSensor Pod 150 IntegratedQA1203180378 Sensor PodSensor Pod 150 IntegratedQA1203180335 Sensor PodSensor Pod 150 IntegratedQA1249180198 Sensor PodSensor Pod 150 IntegratedQA1203180290 Sensor PodSensor Pod 150 IntegratedQA1150180148 Sensor PodSensor Pod 150 IntegratedQA1203180316 Sensor PodSensor Pod 150 IntegratedQA1203180386 Sensor PodSensor Pod 150 IntegratedQA1203180291 Sensor PodSensor Pod 150 IntegratedQA1203180298 Sensor PodSensor Pod 150 IntegratedQA1249180291 Sensor PodSensor Pod 150 IntegratedQA1242180266 ? APPENDIX B HARDWARE SERIAL NUMBER REFERENCE (DOES NOT INCLUDE IDF/ SWITCH CLOSETS CONTENTS) EntitlementMaintenance VisitsStart DateEnd Date 1?Preventive?Maintenance?Visit?5X8209-20-201609-19-2017 Product DescriptionProductSerial # InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1143000007 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1143000002 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1149012829 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1149012827 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1149012831 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1149012834 EntitlementMaintenance VisitsStart DateEnd Date 1?Preventive?Maintenance?Visit?5X8209-20-201609-19-2017 Product DescriptionProductSerial # SYMMETRA?PX?40kW?EXTENDED?RUN?BATTERY?FRAMESYCFXR8PD1203150100 SYMMETRA?PX?40kW?EXTENDED?RUN?BATTERY?FRAMESYCFXR8PD1203150104 EntitlementMaintenance VisitsStart DateEnd Date 1?Preventive?Maintenance?Visit?5X8609-20-201609-19-2017 Product DescriptionProductSerial # InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1143000007 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1143000002 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1149012829 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1149012827 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1149012831 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1149012834 EntitlementMaintenance VisitsStart DateEnd Date 1?Preventive?Maintenance?Visit?5X8309-20-201609-19-2017 Product DescriptionProductSerial # 120?V?TYPE?PDUPSX-PDU120VPI1145160022 SYMMETRA?PX?40KW?FRAME,?208VSYCF40KFPD1204150024 EntitlementMaintenance VisitsStart DateEnd Date 1?Preventive?Maintenance?Visit?5X8309-20-201609-19-2017 Product DescriptionProductSerial # SYMMETRA?PX?40kW?EXTENDED?RUN?BATTERY?FRAMESYCFXR8PD1203150100 SYMMETRA?PX?40kW?EXTENDED?RUN?BATTERY?FRAMESYCFXR8PD1203150104 EntitlementMaintenance VisitsStart DateEnd Date 7X24?Telephone?Technical?Support?-?1?Year09-20-201609-19-2017 Product DescriptionProductSerial # SYMMETRA?PX?40kW?EXTENDED?RUN?BATTERY?FRAMESYCFXR8PD1203150100 SYMMETRA?PX?40kW?EXTENDED?RUN?BATTERY?FRAMESYCFXR8PD1203150104 EntitlementMaintenance VisitsStart DateEnd Date 8-Hour?7X24?Response?On-Site?Service?Upgrade?-?1?Year09-20-201609-19-2017 Product DescriptionProductSerial # 120?V?TYPE?PDUPSX-PDU120VPI1145160022 120?V?TYPE?RDPPSX-RDP120VPI1105170003 120?V?TYPE?RDPPSX-RDP120VPI1051170009 SYMMETRA?PX?40KW?FRAME,?208VSYCF40KFPD1204150024 SYMMETRA?PX?40kW?EXTENDED?RUN?BATTERY?FRAMESYCFXR8PD1203150100 SYMMETRA?PX?40kW?EXTENDED?RUN?BATTERY?FRAMESYCFXR8PD1203150104 EntitlementMaintenance VisitsStart DateEnd Date 8-Hour?7X24?Response?On-Site?Service?Upgrade?-?1?Year09-20-201609-19-2017 Product DescriptionProductSerial # InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1143000007 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1143000002 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1149012829 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1149012827 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1149012831 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1149012834 EntitlementMaintenance VisitsStart DateEnd Date Assembly?Service?5X809-20-201609-19-2017 Product DescriptionProductSerial # InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1143000007 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1143000002 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1149012829 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1149012827 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1149012831 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1149012834 EntitlementMaintenance VisitsStart DateEnd Date Assembly?Service?5X809-20-201609-19-2017 Product DescriptionProductSerial # SYMMETRA?PX?40kW?EXTENDED?RUN?BATTERY?FRAMESYCFXR8PD1203150100 SYMMETRA?PX?40kW?EXTENDED?RUN?BATTERY?FRAMESYCFXR8PD1203150104 EntitlementMaintenance VisitsStart DateEnd Date Assembly?Service?5X809-20-201609-19-2017 Product DescriptionProductSerial # NetBotz?Rack?Monitor?550?(with?120/240V?Power?Supply)NBRK0551QA1210180122 NetBotz?Rack?Monitor?550?(with?120/240V?Power?Supply)NBRK0551 NetBotz?Room?Monitor?355?(without?PoE?Injector)NBWL0355QA1203180335 EntitlementMaintenance VisitsStart DateEnd Date Assembly?Service?5X809-20-201609-19-2017 Product DescriptionProductSerial # NetShelter?SX?42U?600mm?Wide?x?1070mm?Deep?Enclosure?with?Sides?BlackAR3100ON12111A0189 NetShelter?SX?42U?600mm?Wide?x?1070mm?Deep?Enclosure?with?Sides?BlackAR3100ON12111A0192 NetShelter?SX?42U?600mm?Wide?x?1070mm?Deep?Enclosure?with?Sides?BlackAR3100ON12111A0188 NetShelter?SX?42U?600mm?Wide?x?1070mm?Deep?Enclosure?with?Sides?BlackAR3100ON12111A0187 NetShelter?SX?42U?600mm?Wide?x?1070mm?Deep?Enclosure?with?Sides?BlackAR3100ON12111A0195 NetShelter?SX?42U?600mm?Wide?x?1070mm?Deep?Enclosure?with?Sides?BlackAR3100ON12111A0193 NetShelter?SX?42U?600mm?Wide?x?1070mm?Deep?Enclosure?with?Sides?BlackAR3100ON12111A0191 NetShelter?SX?42U?750mm?Wide?x?1070mm?Deep?Enclosure?with?Sides?BlackAR3150ON12092A0019 NetShelter?SX?42U?750mm?Wide?x?1070mm?Deep?Enclosure?with?Sides?BlackAR3150ON12092A0017 EntitlementMaintenance VisitsStart DateEnd Date Assembly?Service?5X809-20-201609-19-2017 Product DescriptionProductSerial # NetShelter?SX?42U?600mm?Wide?x?1070mm?Deep?Enclosure?with?Sides?BlackAR3100ON12111A0191 NetShelter?SX?42U?600mm?Wide?x?1070mm?Deep?Enclosure?with?Sides?BlackAR3100ON12111A0186 NetShelter?SX?42U?600mm?Wide?x?1070mm?Deep?Enclosure?with?Sides?BlackAR3100ON12111A0295 NetShelter?SX?42U?600mm?Wide?x?1070mm?Deep?Enclosure?with?Sides?BlackAR31008N1210E11188 EntitlementMaintenance VisitsStart DateEnd Date Assembly?Service?5X809-20-201609-19-2017 Product DescriptionProductSerial # 120?V?TYPE?PDUPSX-PDU120VPI1145160022 SYMMETRA?PX?40KW?FRAME,?208VSYCF40KFPD1204150024 EntitlementMaintenance VisitsStart DateEnd Date Assembly?Service?5X809-20-201609-19-2017 Product DescriptionProductSerial # 120?V?TYPE?RDPPSX-RDP120VPI1105170003 120?V?TYPE?RDPPSX-RDP120VPI1051170009 EntitlementMaintenance VisitsStart DateEnd Date Battery?Preventive?Maintenance?Visit?5x8209-20-201609-19-2017 Product DescriptionProductSerial # SYMMETRA?PX?40kW?EXTENDED?RUN?BATTERY?FRAMESYCFXR8PD1203150100 SYMMETRA?PX?40kW?EXTENDED?RUN?BATTERY?FRAMESYCFXR8PD1203150104 EntitlementMaintenance VisitsStart DateEnd Date Data?Center?Capacity?Manager?and?Basic?Configuration?Services09-20-201609-19-2017 Product DescriptionProductSerial # NetBotz?Rack?Monitor?550?(with?120/240V?Power?Supply)NBRK0551QA1210180122 EntitlementMaintenance VisitsStart DateEnd Date Netbotz?Configuration?Service?in?ISX?Designer?109-20-201609-19-2017 Product DescriptionProductSerial # NetBotz?Rack?Monitor?550?(with?120/240V?Power?Supply)NBRK0551QA1210180122 EntitlementMaintenance VisitsStart DateEnd Date 09-20-201609-19-2017 Product DescriptionProductSerial # SYMMETRA?PX?40kW?EXTENDED?RUN?BATTERY?FRAMESYCFXR8PD1203150100 SYMMETRA?PX?40kW?EXTENDED?RUN?BATTERY?FRAMESYCFXR8PD1203150104 EntitlementMaintenance VisitsStart DateEnd Date Next?Business?Day?On-Site?Service?for?Internal?Batteries?-?1?Year09-20-201609-19-2017 Product DescriptionProductSerial # SYMMETRA?PX?40kW?EXTENDED?RUN?BATTERY?FRAMESYCFXR8PD1203150100 SYMMETRA?PX?40kW?EXTENDED?RUN?BATTERY?FRAMESYCFXR8PD1203150104 EntitlementMaintenance VisitsStart DateEnd Date On?Site?Warranty?Extension?for?Battery?Frames?1?Year09-20-201609-19-2017 Product DescriptionProductSerial # SYMMETRA?PX?40kW?EXTENDED?RUN?BATTERY?FRAMESYCFXR8PD1203150100 SYMMETRA?PX?40kW?EXTENDED?RUN?BATTERY?FRAMESYCFXR8PD1203150104 EntitlementMaintenance VisitsStart DateEnd Date On?Site?Warranty?Extension?for?Internal?Batteries?1?Year09-20-201609-19-2017 Product DescriptionProductSerial # SYMMETRA?PX?40kW?EXTENDED?RUN?BATTERY?FRAMESYCFXR8PD1203150100 SYMMETRA?PX?40kW?EXTENDED?RUN?BATTERY?FRAMESYCFXR8PD1203150104 EntitlementMaintenance VisitsStart DateEnd Date Onsite?Warranty?Extension?1?Year09-20-201609-19-2017 Product DescriptionProductSerial # 120?V?TYPE?PDUPSX-PDU120VPI1145160022 SYMMETRA?PX?40KW?FRAME,?208VSYCF40KFPD1204150024 EntitlementMaintenance VisitsStart DateEnd Date Onsite?Warranty?Extension?1?Year09-20-201609-19-2017 Product DescriptionProductSerial # 120?V?TYPE?RDPPSX-RDP120VPI1105170003 120?V?TYPE?RDPPSX-RDP120VPI1051170009 EntitlementMaintenance VisitsStart DateEnd Date Onsite?Warranty?Extension?1?Year09-20-201609-19-2017 Product DescriptionProductSerial # InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1143000007 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1143000002 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1149012829 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1149012827 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1149012831 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1149012834 EntitlementMaintenance VisitsStart DateEnd Date Level?2?Training09-20-201609-19-2017 Product DescriptionProductSerial # SYMMETRA?PX?40KW?FRAME,?208VSYCF40KFPD1204150024 EntitlementMaintenance VisitsStart DateEnd Date QWINSTALL-QJCR32235-00?-?RD?INSTALL09-20-201609-19-2017 EntitlementMaintenance VisitsStart DateEnd Date Site?Coordination?Service09-20-201609-19-2017 Product DescriptionProductSerial # SYMMETRA?PX?40KW?FRAME,?208VSYCF40KFPD1204150024 EntitlementMaintenance VisitsStart DateEnd Date Site?Inspection?5X8209-20-201609-19-2017 Product DescriptionProductSerial # 120?V?TYPE?PDUPSX-PDU120VPI1145160022 SYMMETRA?PX?40KW?FRAME,?208VSYCF40KFPD1204150024 EntitlementMaintenance VisitsStart DateEnd Date Site?Inspection?5X8209-20-201609-19-2017 Product DescriptionProductSerial # 120?V?TYPE?RDPPSX-RDP120VPI1105170003 120?V?TYPE?RDPPSX-RDP120VPI1051170009 EntitlementMaintenance VisitsStart DateEnd Date Startup?Service?5x809-20-201609-19-2017 Product DescriptionProductSerial # InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1143000007 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1143000002 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1149012829 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1149012827 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1149012831 InRow?RD,?300mm,?Fluid?Cooled,?208-230V,?60HzACRD200JK1149012834 EntitlementMaintenance VisitsStart DateEnd Date Startup?Service?5x809-20-201609-19-2017 Product DescriptionProductSerial # 120?V?TYPE?PDUPSX-PDU120VPI1145160022 SYMMETRA?PX?40KW?FRAME,?208VSYCF40KFPD1204150024 EntitlementMaintenance VisitsStart DateEnd Date Startup?Service?5x809-20-201609-19-2017 Product DescriptionProductSerial # SYMMETRA?PX?40kW?EXTENDED?RUN?BATTERY?FRAMESYCFXR8PD1203150100 SYMMETRA?PX?40kW?EXTENDED?RUN?BATTERY?FRAMESYCFXR8PD1203150104 This service agreement does not apply to equipment which has been damaged due to accident, negligence, abuse, improper installation or misapplication, or which has been altered or modified in any way. Any terms and conditions that normally apply to the factory warranty which accompanies the product will also apply to this entitlement. See documentation accompanying product for applicable warranty details, and attachment for entitlement terms and conditions.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/WDCVARO372/WDCVARO372/VA101V16Q0443/listing.html)
 
Document(s)
Attachment
 
File Name: VA101V-16-Q-0443 A00003 VA101V-16-Q-0443 A00003.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3006868&FileName=VA101V-16-Q-0443-A00003000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3006868&FileName=VA101V-16-Q-0443-A00003000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: DEPARTMENT OF VETERANS AFFAIRS;VBA ST PAUL REGIONAL OFFICE (335);BISHOP HENRY WHIPPLE BUILDING;1 FEDERAL DRIVE;ST PAUL MN
Zip Code: 55111
 
Record
SN04273399-W 20160917/160915235648-a1ef4589e3fdd3393c39960234505526 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers