Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JULY 31, 2016 FBO #5364
DOCUMENT

65 -- Continuous Veno-Venous Hemofiltration - Attachment

Notice Date
7/29/2016
 
Notice Type
Attachment
 
NAICS
339113 — Surgical Appliance and Supplies Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office (NCO) 10;6150 Oak Tree Blvd., Suite 300;Independence OH 44131
 
ZIP Code
44131
 
Solicitation Number
VA25016Q0461
 
Archive Date
8/29/2016
 
Point of Contact
Christopher A. Callihan
 
E-Mail Address
k
 
Small Business Set-Aside
N/A
 
Description
INTENT TO SOLE SOURCE FAR 13.106(B) This is a notice of intent of The Louis Stokes Cleveland Department of Veterans Affairs Medical Center, 10701 East Boulevard, Cleveland, Ohio 44106 to negotiate sole source with BAXTER HEALTHCARE CORPORATION for supplying The Department of Veterans Affairs Medical Center, Cleveland Ohio, Medical Service with the following Prismaflex CVVH Machine Background The Prismaflex CVVH (continuous veno-venous hemofiltration) system is used to provide renal replacement therapy in critically ill patients who have acute kidney injury and are not able to tolerate conventional hemodialysis. "The Louis Stokes Cleveland DVAMC currently has 3 machines which are used in the MICU, CCU and SICU. The need for CVVH remains high, with post-operative Acute Kidney Injury, and patients with multisystem illnesses in the MICU/CCU critical care units. "The current number of units is insufficient to meet peak patient demand time while providing back up in case of failure of one of the existing units. Due to the critical need of this treatment, repair time for failed units is not an option as treatment delay directly impacts patient mortality. In the past, a rental company was used to access a CVVH machine when both VA units were in use or under repair. However, this service has become more erratic and unreliable due to demand for CVVH machines. Scope "The contractor shall provide all resources necessary to support the Electrophysiology Laboratory requirement below, at the Louis Stokes Cleveland VA Medical Center 3 EA ?Prismaflex CVVH Machine "Salient Characteristics: -Shall be capable of Continuous Veno-Venous Hemofiltration (CVVH) short-term treatment for in-patients with kidney dysfunction accompanied by low blood pressure. Therapy shall be performed in the ICU or OR setting as applicable. oThe Continuous Veno-Venous Hemofiltration (CVVH) program is a short term treatment used in ICU patients with acute or chronic renal failure. Usually, hemodialysis is typically done for patients with kidney failure. However, if the patient has low blood pressure or other contraindicators to hemodialysis, CVVH may be a necessary alternative. -Shall be able to provide this treatment to ICU or post-operative patients in need of this support. Use of this system improves patient outcomes and recovery due to the limited time this support is necessary and using this intervention avoids use of full hemodialysis support in the longer term effecting shorter recovery times and cost reduction for the medical center. -The PRISMAFLEX System can be used for: oCVVHDF - Continuous Veno-Venous Hemodiafiltration oCVVHD - Continuous Veno-Venous Hemodialysis oCVVH - Continuous Veno-Venous Hemofiltration oSCUF - Slow Continuous Ultrafiltration oTPE - Therapeutic Plasma Exchange The Government believes that only one business can satisfy the agency requirements and intends to negotiate with only one source under the authority of FAR 13.106(b) - access to proprietary information. Other persons may identify their interest and capability to respond to this requirement by Thursday August 04, 2016 at 3PM EST. Such capabilities information will be used solely for the purpose of determining whether or not to conduct this procurement on a competitive basis. All information shall be furnished at no cost or obligation to the Government. A determination by the Government not to open the requirement to competition based upon responses to this notice is solely within the discretion of the Government. No solicitation is available at this time. All inquiries must be submitted by email to Christopher Callihan at christopher.callihan@va.gov
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/BreVAMC/VAMCCO80220/VA25016Q0461/listing.html)
 
Document(s)
Attachment
 
File Name: VA250-16-Q-0461 VA250-16-Q-0461.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2908451&FileName=VA250-16-Q-0461-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2908451&FileName=VA250-16-Q-0461-000.docx

 
File Name: VA250-16-Q-0461 P03 - Sole Source 3K-150K Open Market (Prismaflex)-2016-05-29.pdf (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2908452&FileName=VA250-16-Q-0461-001.pdf)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2908452&FileName=VA250-16-Q-0461-001.pdf

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN04201877-W 20160731/160729234753-a31ab07380c0a061ee101419cb6058bc (fbodaily.com)
 