Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 30, 2015 FBO #5028
SOURCES SOUGHT

41 -- IR Heaters

Notice Date
8/28/2015
 
Notice Type
Sources Sought
 
NAICS
333414 — Heating Equipment (except Warm Air Furnaces) Manufacturing
 
Contracting Office
Department of the Army, Army Contracting Command, ACC- Warren (ACC-WRN)(SIAD), 74 C STREET, Herlong, California, 96113-5000, United States
 
ZIP Code
96113-5000
 
Solicitation Number
W912GYRFI082615
 
Point of Contact
Tracy Marino, Phone: (530) 827-4831, Tamara Gage, Phone: (530) 827-4825
 
E-Mail Address
tracy.marino4.civ@mail.mil, tamara.a.gage.civ@mail.mil
(tracy.marino4.civ@mail.mil, tamara.a.gage.civ@mail.mil)
 
Small Business Set-Aside
N/A
 
Description
Sierra Army Depot is conducting market research to determine the availability of infrared heaters, fans and controls that meet a brand name, or equal item, specifications listed in the RFI section. REQUEST FOR INFORMATION Items requested: Infratech or an equal item. "Or Equal Item" specs must meet: Heater 1 (W3048) - Medium wave heaters, overall 61.25" long x 8" wide, 3000 Watts, 480V, single quartz element, cold rolled steel, powder coated with mounting brackets. Two ¼" mounting holes are located on each end of the heater. The distance between all 4 holes are 60.1875" apart in the horizontal direction (critical) and 4" in the vertical direction. The IR fixtures has 120 degree reflector. The height of the heater shall not exceed 9.375" high. Heater 2 (W4048) - Medium wave heaters, overall 61.25" long x 8" wide, 4000 Watts, 480V, single quartz element, cold rolled steel, powder coated with mounting brackets. Two ¼" mounting holes are located on each end of the heater. The distance between all 4 holes are 60.1875" apart in the horizontal direction (critical) and 4" in the vertical direction. The IR fixtures has 120 degree reflector. The height of the heater shall not exceed 9.375" high. Fan Assembly 1 - Fan assembly consist of two 120V with less than 1 amp fans that can be used in either direction with roughly 240 CFM of output at 600 lineal feet per minutes from each blower. Mounting shall be located on the back side so that the unit will face the objects when mounted. The mounting pattern shall be in the center of the body with a bolt pattern 2.5" in the horizontal direction (x) 1.5" in the vertical. Custom Control 1, UL Listed oven control panel, 126KW, 200 Amp, 480V 3ph to control thirty six of Heater 1, sixteen fans, and, two S9000 infrared unit, described above. Lamps are @ 480V, and fans are at 120V. The zone configuration will be as follows: ZONE 1: - 12 - W3048 IR Heaters, 6 - speed dry fans ZONE 2: - 12 - W3048 IR Heaters, 5 - speed dry fans ZONE 3: - 12 - W3048 IR Heaters, 3 - speed dry fans ZONE 4: - 2 - S9000 (480V) IR units, 2 speed dry fans mounted to lamps. This controller will have timer, intensity adjustment, and PID with thermocouple sensor. Each zone has an on/off switch with lamps on the panel that is illuminate when the zone is on. Once the zones are selected the timer and intensity controls are set. Each zone is monitored by a 1 to 1 non-contact thermocouple sensor and communicates with a PID controller that gives a digital temperature read out and controls the heat insuring paint to not blister. PID controls will include selector switch to bypass and use manual intensity control. Custom Control 2, UL Listed Oven Control Panel, 160KW, 250 Amp, 480V 3ph. Custom Control controls forty Heater 2. This controller will control eight zones with five IR heaters per zone. Each zone has to function independently. This controller will have timers, intensity adjustment, and PID thermo-sensor for each zone. Each zone has an on/off switch with lamps on the panel that is illuminate when the zone is on. Once the zones are selected the timer and intensity controls are set. Each zone is monitored by a 5 to 1 non-contact thermocouple sensor and communicates with a PID controller that gives a digital temperature read out and controls the heat insuring paint to not blister. PID controls will include selector switch to bypass and use manual intensity control. At this time Sierra Army Depot is NOT looking for proposals/quotes. NO SOLICITATION EXISTS AT THIS TIME. This RFI does not constitute an Invitation for Bid, Request for Proposal or a Request for Quote and is not to be construed as a commitment by the Government to issue an order or otherwise pay for the information solicited. Responses to this RFI are due 14 September 2015, 5:00 (Pacific Time). Responses can be sent to tracy.l.marino4.civl@mail.mil. Further action on this anticipated requirement will be determined following review of the responses from this RFI. All correspondence regarding this RFI should be addressed to Tracy Marino, Contracting Officer, Place of Delivery: Sierra Army Depot, Herlong California
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/a6758168f54765bc1930aefaea215533)
 
Place of Performance
Address: Herlong, California, 96113, United States
Zip Code: 96113
 
Record
SN03862302-W 20150830/150829000141-a6758168f54765bc1930aefaea215533 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)