H -- Boiler Controls - Attachment

Notice Date
10/30/2014
 
Notice Type
Attachment
 
NAICS
561210 — Facilities Support Services
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 9;1639 Medical Center Parkway;Suite 400;Murfreesboro TN 37129
 
ZIP Code
37129
 
Solicitation Number
VA24915R0061
 
Archive Date
11/14/2014
 
Point of Contact
Phon Phasavath
 
E-Mail Address
esboro
 
Small Business Set-Aside
Total Small Business
 
Description
The Department of Veterans Affairs Medical Center, NCO 9 Network Contracting Office, on behalf of Veterans Administration Medical Center Louisville, is conducting market research through this sources sought notice to seek sources for boiler inspection, calibration, and repair of the combustion control systems. The North American Industry Classification System (NAICS) Code for this acquisition is 561210. Disclaimer and Important Notes: This Sources Sought Notice is for market research purposes only and does not constitute a Request for Proposal/Quotation; and, it is not considered to be a commitment by the Government to award a contract nor will the Government pay for any information provided; no basis for claim against the Government shall arise as a result from a response to this Sources Sought Notice or Government use of any information provided. Failure to submit information in sufficient detail may result in considering a company as not a viable source and may influence competition and set-aside decisions. Regardless of the information obtained from this Sources Sought Notice, the Government reserves the right to consider any arrangement as deemed appropriated for this requirement. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. No proprietary, classified, confidential, or sensitive information should be included in your response to this Sources Sought Notice. The Government reserves the right to use any information provided by respondents for any purpose deemed necessary and legally appropriate, including using technical information provided by respondents in any resultant solicitation. At this time no solicitation exists; therefore, Do Not Request a Copy of the Solicitation. After a review of the responses received, a comvined synopsis may be published on Federal Business Opportunities (FedBizOpps) website. It is the potential offeror's responsibility to monitor FedBizOpps for release of any future solicitation that may result from this Sources Sought Notice. However, responses to this Sources Sought Notice will not be considered adequate responses to any resultant solicitation. Pursuant to FAR Part 10 (Market Research), the purpose of this notice is to: (1) determine if sources capable of satisfying the agency's requirements exists, (2) determine if commercial items suitable to meet the agency's needs are available or could be modified to meet the agency's requirements, and (3) determine the commercial practices of company's engaged in providing the needed service or supply. Pursuant to FAR Part 6 and FAR Part 19, competition and set-aside decisions may be based on the results of this market research. This notice in no way obligates the Government to any further action. SAM: Interested parties should register in the SAM as prescribed in FAR Clause 52.232-33. The SAM can be obtained by accessing the internet at www.sam.gov. Submission of Information: Companies having capabilities necessary to meet or exceed the stated requirements are invited to provide information to contribute to this market survey/sources sought notice including commercial market information and company information. Companies may respond to this Sources Sought Notice via e-mail to Phon Phasavath1@va.gov or via fax to (615) 849-3769 (Attn: Phon Phasavath) no later than 3 November, 2014 at 8:00 AM, Central Time with the following information/documentation: 1. Name of Company, Address and DUNS Number. 2. Point of Contact and Phone Number. 3. Business Size applicable to the NAICS Code: a. HuBZone Small Business Concern; b. Service-Disabled Veteran Owned Small Business Concern (SDVOSBC); c. Veteran Owned Small Business Concern (VOSBC); d Small Business Concern; e. Large Business Concern 4. Documentation Verifying Small Business Certification: a. If claiming HuBZone status, provide a copy of your HuBZone Certificate from SBA. b. If claiming SDVOSBC status, provide documentation that shows the Service Disable Veteran (SDV) unconditionally owns 51 % of the business, controls the management and daily operations, and holds the highest officer position in the company. Documentation should also be provided to show that the SDV has a service-connected disability that has been determined by the Department of Defense or Department of Veteran Affairs. Finally, provide documentation that shows the business is small under the NAICS code 561210. c. If claiming VOSBC status, provide documentation that shows the Veteran unconditionally owns 51% of the business, controls the management and daily operation, make long-term decisions for the business, and holds the highest officer position in the company that works at the business fulltime during normal working hours. The documentation should also show the business is small under the NAICS code 561210. d. If claiming Small Business status, provide documentation to show the business is small under NAICS code 561210. STATEMENT OF WORK MAINTENANCE ON BOILER CONTROLS TVHS VA Medical Center Nashville and Murfreesboro Campus 1. INTRODUCTION AND STATEMENT OF WORK: Offeror shall furnish all labor, tools, and equipment necessary to inspect, calibrate, adjust, repair and maintain in first class operating condition the boiler combustion controls, associated recording instrumentation (boiler computer system), burner management, flame failure controls, Deaerating Feed Tank (DA Tank), Pressure Reducing Valves (PRV), and safety devices, on the boilers listed below and in the boiler plant in the manner and frequency as stipulated in the VHA Boiler Safety Manual 3rd edition (Reference A). See requirements for list of equipment needed. Service visit includes annual boiler and safety training for boiler operators as required by VHA 2008-062 (Reference B). All work should be coordinated with the Utility Systems Supervisor at Nashville and Murfreesboro VA Medical Centers (VAMCs) and done with boiler operators for training purposes. Service visit requires 5 consecutive full working days, Mon-Fri, 7:30am to 4pm. Safety Checks and fuel/air settings must be in accordance with excess air requirements as set by the manufacturer (Cleaver-Brooks) for the specific boiler type and by the VA VHA Boiler Plant Safety Devices Testing Manual, 3rd Edition (Reference A) and VHA Boiler Policy (VHA 2008-062) Reference B. Combustion calibration of oil and gas must be made from 0% to 100% in 5% increments should be done EACH QUARTER. Check pilot light ignition on natural gas and propane. Test and calibrate boiler water level control system to include high and low water alarm systems. Complete all boiler safety checks in plant as listed in the safety manual, test conducted and at a time frequency described in the VHA Boiler Safety Manual 3rd edition (Reference A). Any device, system or part failure should be immediately reported to the Utility Systems Operator Supervisor. It is expected that upon the completion of the required service that all boilers will be returned to a normal operating condition. A complete report will be given to the Utility Systems Supervisor within 2 business days of the completion of work, 2 copies, one bound hard copy and one electronic copy on DVD. Parts are not included in this contract. VAMC Nashville Campus: There are three Cleaver Brooks 4 pass high pressure gas and oil fired fire tube boilers with Autoflame ® controls, Model 4WI-200-600-200. The boilers are 600 HP and operate at approximately 90 psi. VAMC Murfreesboro Campus: There are three Cleaver Brooks high pressure gas and oil fired fire tube boilers with Hawk 4000 ® controls, Model 4WI-200-600-200. The boilers are 600 HP and operate at approximately 100 psi. 2. REQUIREMENTS: This is a base plus 4 yearly options contract. Period of performance will begin on December 1, 2014 through November 30, 2015. All work must be performed by a certified and experienced service technician during normal working hours, 8:00 a.m. to 4:30 p.m., Monday through Friday. Contractors must have proof of training by Autoflame and have computers, software, and devices needed to access the Autoflame controls and calibrate all safety devices. Contractor will schedule each service visit at least two weeks prior to the visit. Each service visit during the months of October, January, April, and July will consist of a minimum of five (5) days each on the job site. In the case that the contract year does not start in October, the first scheduled visit will be scheduled with the COR within 14 calendar days of the contract being awarded. These service periods cannot be adjusted and shall be met by selected Offeror or coordinated at least three weeks of schedule change. a. Nashville Campus (1) Three Cleaver Brooks fire tube boilers and associated safety devices (2) Three Autoflame Control Panels (MM) (3) Three Operating Steam Pressure Limit (Autoflame MM) (4) Six Steam Pressure Limit switches, one recycle and one reset (Mercoid Switch) (5) Nine Safety Relief Valve testing (3 on each boiler) (Kunkle 125, 130, 135 psi) (6) Three Antunes Purge Air Flow Switches (7) Three Outlet Damper Interlock (8) Three High furnace pressure switch (9) Three Auxiliary Low water - Warrick float (10) Three Autoflame radio frequency dual probe for water level and high and low water alarms (11) Three Autoflame self check UV scanner flame scanner (12) Three Combustion air pressure switch - Honeywell (13) Three Autoflame ignition timing and flame confirmation (IR Fire eye) (14) Three System failure Response time (Autoflame MM) (15) Three Low Gas Pressure - Autoflame sensor (16) Three Low gas Pressure Mercoid PRL-3-P1 (17) Three High Gas Pressure Mercoid PRLPP2 (18) Three Low Gas Pressure - Antunes LGPAM1 (19) Six Main gas valve - POC and leak test (20) Six Main oil valve - POC and leak test (21) Three Low atomizing air pressure switch Mercoid 804-24K (22) Three Low oil pressure switch Mercoid (23) Three High oil pressure switch Mercoid (24) Three Low oxygen sensors (25) Combustion controls will be adjusted to maintain the proper fuel/air ratio for the most efficient and safe operation throughout the firing range at a maximum of 5% intervals. (26) Calibration of all transmitters and meters to ensure accurate reading. (27) Testing of PRV's, steam stations, and accumulation test per VA Safety Manual (Reference A). (28) Testing of all safety devices on new DA Tank (29) Calibration of gas sensors and alarms in boiler plant. (30) Boiler computer monitoring network including 2 PC's (one in boiler plant, one in Utility System Supervisors office). (31) Three high water alarm conductivity probes (Warrick) (32) Calibrate all flow transmitters (Steam, Gas, Oil, Water) (33) Any Boiler safety or Plant safety items in Safety Manual (Reference A) not listed above. a. Murfreesboro Campus (1) Three Cleaver Brooks fire tube boilers and associated safety devices (2) Three Hawk 4000 Control Panels (3) Three Operating Steam Pressure Limit (4) Six Steam Pressure Limit switches, one recycle and one reset (Mercoid Switch) (5) Nine Safety Relief Valve testing (3 on each boiler) (Kunkle 125, 130, 135 psi) (6) Three Antunes Purge Air Flow Switches (7) Three Outlet Damper Interlock (8) Three High furnace pressure switch (9) Three Auxiliary Low water - Warrick float (10) Three Warrick dual probe for water level and high and low water alarms (11) Three Fireeye self-check UV scanner flame scanner (12) Three Combustion air pressure switch (13) Three ignition timing and flame confirmation (IR Fire eye) (14) Three System failure Response time (15) Three Low Gas Pressure (16) Three Low gas Pressure Mercoid PRL-3-P1 (17) Three High Gas Pressure Mercoid PRLPP2 (18) Three Low Gas Pressure - Antunes LGPAM1 (19) Six Main gas valve - POC and leak test (20) Six Main oil valve - POC and leak test (21) Three Low atomizing air pressure switch Mercoid 804-24K (22) Three Low oil pressure switch Mercoid (23) Three High oil pressure switch Mercoid (24) Three Low oxygen sensors (25) Combustion controls will be adjusted to maintain the proper fuel/air ratio for the most efficient and safe operation throughout the firing range at a maximum of 5% intervals. (26) Calibration of all transmitters and meters to ensure accurate reading. (27) Testing of PRV's, steam stations, and accumulation test per VA Safety Manual (Reference A). (28) Testing of all safety devices on DA Tank (29) Calibration of gas sensors and alarms in boiler plant. (30) Boiler computer monitoring network. (31) Three high water alarm conductivity probes (Warrick) (32) Calibrate all flow transmitters (Steam, Gas, Oil, Water) (33) Any Boiler safety or Plant safety items in Safety Manual (Reference A) not listed above. Boiler excess air and oxygen shall be maintained throughout the firing range on gas and oil in accordance with burner manufacturer's burner recommendations (Cleaver-Brooks) Exhaust gas test is conducted using Autoflame ® EGA system. System should be checked for calibration and proper operation per manufacturer (Autoflame) recommendations. Parts are not included: however, during each service call, the contractor will submit a list containing each part needed and prices to the Engineering Service Office. Approval must be obtained from the Maintenance & Operations General Supervisor or a designee thereof and Contracting officer prior to providing the VA the part. The contractor will invoice the VA on a separate purchase order and include an itemized listing of parts used. The contractor will submit to the Chief Engineer through the Utility Systems Supervisor and the M&O Supervisor, a written report stating his findings and recommendations of proper operations and maintenance condition of the boiler and plant. Tools of the trade: Contractor must have complete test and tools of the trade require for testing and calibrating Cleaver-Brooks boilers with Autoflame and Hawk 4000 controls including Autoflame combustion software (latest version), laptop, connection cord to connect laptop to Autoflame MM and Hawk 4000, Digital Manometer (calibrated annually may be requested to provide proof of calibration), nitrogen pressure tank and connection fittings/assembly to test boiler safeties as required in the VA Boiler Safety Manual 3rd Edition (Reference A), digital device to calibrate flow transmitters (such as a Yokagowa), and test gas and device to test gas detection system for the boiler plant. Various hand held tools as wells including electrical meters, jumpers, wrenches, screw drivers, etc ¦ The contractor is required to provide all their own tools and equipment, none to be provided by the VA. VA equipment may be used when training VA boiler operators if VA equipment differs in operation from vendor. Competency of Personnel (Qualifications): An experienced and certified industrial boiler service representative is required. Proof of experience and training may be requested. No welded repairs are permitted except by certified welders using code-approved procedures. Contractors should be trained in Autoflame and Hawk 4000 boiler control systems and have a minimum of three years of boiler calibration and safety checks on all standard type of boiler devices and switches, and testing in manner and frequency of VHA Boiler Safety Manual, 3rd Edition (Reference A). This work requires two sets of skills, the first is the Autoflame and Hawk 4000 combustion control system, and the other is the VA Safety Testing Manual process (Reference A). 3. DELIVERY: All work must be performed by a certified and experienced service technician during normal working hours, 8:00 a.m. to 4:30 p.m., Monday through Friday. Each service visit during the months of October, January, April, and July will consist of a minimum of five (5) days each on the job site. Rescheduling process: If selected offeror cannot meet this required schedule a three week written notice is required and shall include the proposed new dates for subject visit. This written notification shall be provided to the VA Contracting Officer and COR for agreement if conditions don't permit a visit during the designated month. a.During preventative maintenance (PM) inspections and emergency service calls the service technician will be accompanied by the respective campus Utility Systems Operator Supervisor or a designee thereof. b.Service visit shall include training of boiler plant operators on operation and testing of safety devices. Contractor should work closely with VA boiler operators during all phases of calibration and testing. c.Each device must be recorded using the forms in the VA Safety Manual. All these forms must be included in the testing report provided to the COR. 4. PROGRESS AND COMPLIANCE: a.After each scheduled PM or emergency maintenance call is complete, the qualified service technician shall leave a signed service ticket with the Utility Systems Operator Supervisor or his designee detailing work completed failure of any device and recommended remedial action. b. Payments will be made in arrears upon receipt of certified invoice and signed service report. 5. NOTES AND OTHER INFORMATION: a.There are no known security issues with this Statement of Work. b.Contractors are responsible for finding their own parking. Currently, contractors cannot park at the VAMC Nashville Campus. Contractors may park temporarily to drop off tools and supplies only. c.Contractors are required to obtain Temporary ID Badge from Engineering Service, Room D73 Nashville or Building 6 Murfreesboro, while on VA property if not escorted during entire visit by an Engineering Service employee. d.Boiler Efficiency Institute (BEI) testing sheets should be used for each test and include the make, model, setting, trip point, whether the test passed or failed, if failed - recommended repair. Complete report should be given to the Utility System Supervisor prior to leaving the boiler plant on the 2 calendar days of the completion of the work detailing all contractor work including the testing of safety devices listed above, and also all combustion and emission data at 5% intervals. 6. Solicitation Note(s): Important Instructions to all Offerors: a.An unsupported statement "Complies" to technical specifications contained in this solicitation is not acceptable. b.Also important if proposed contractor solution does not meet ALL of the established technical performance requirements contained in this SOW will be considered to be not technically acceptable, and the submitted proposal will be removed from further consideration. It is incumbent upon Offerors to ensure that all technical requirements are comprehensively addressed in the submitted proposal. 7.EVALUATION FACTORS for Technical Evaluation Panel (TEP) will include the following factors: a.Lowest Price Technically Acceptable (LPTA) Evaluation Criteria This is a request for proposal (RFP). Representatives (TEP) of the Department of Veterans Affairs will evaluate the proposals. Low Price Technically Acceptable procedures-- Award will be made on the basis of the lowest evaluated price of proposals meeting or exceeding the acceptability standards for the technical factors listed in the statement of work and the below non-cost factors. b.Performance Plan (Non-cost factors) The Performance Plan shall be in a narrative format. It shall be a comprehensive document and shall include all of the following elements. Any plan that does not include all of the following elements will result in the proposal being rated "Unacceptable." The elements are: c.Contractor Role The Plan shall detail all components of the requirement that shall be performed by the Contractor. The Plan shall be comprehensive in nature and demonstrate that the contractor has a complete understanding of the requirement. This component of the Plan shall also include key contractor personnel who shall comprise the contractor team to perform this requirement. It also shall include up to three (3) relevant examples of corporate experience in related work and the role of the personnel proposed for this requirement in the past projects. This component of the plan will be evaluated for its comprehensiveness and the relevance of contractor and contractor personnel experience d.Proposal Evaluation The Government intends to evaluate proposals and award a contract without discussions with offerors (except clarifications as described in FAR 15.306(a)). Therefore, the offeror's initial proposal should contain the offeror's best terms. The Government reserves the right to conduct discussions if the Contracting Officer later determines them to be necessary. Further, if the Contracting Officer determines that discussions are necessary and if the Contracting Officer determines that the number of proposals that would otherwise be in the competitive range exceeds the number at which an efficient competition can be conducted. The Contracting Officer may limit the number of proposals in the competitive range to the greatest number that will permit an efficient competition among the most highly rated proposals. e.Technical Evaluation Panel Selection Decision Evaluators will provide results of the evaluations (i.e. Technically Acceptable or Unacceptable) to the Contracting Officer. The lowest priced technically acceptable proposal shall represent the best value to the government. 8. Contractor (Offeror) Required Visit Frequency and Test Schedule: October: M, 6M, A - Calibration gas and oil, 0% to 100%, 5% increments, gas and propane ignition. January: M - Calibration gas and oil, 0% to 100%, 5% increments, gas and propane ignition. April: M, 6M - Calibration gas and oil, 0% to 100%, 5% increments, gas and propane ignition. July: M - Calibration gas and oil, 0% to 100%, 5% increments, gas and propane ignition. 9. Required Inspections and Operational Tests - VHA DIRECTIVE 2008-062 a. Key to Frequency Abbreviations (1) H = Hourly. (2) D = Daily. (3) M = Once per month. (4) 6M = Once every 6 months. (5) Y = Once per year. b. Frequency Chart (8) Adjust burner combustion settings and calibrate oxygen trim. Quarterly (9) Check vibration of burner fans. 6M (10) Calibrate instrumentation, monitoring, and control systems. Quarterly (l1) Operational Testing of Boiler Safety Devices, such as: (a) Low-water cutoff (slow drain) M (b) Fire each boiler and the pilot on the alternate fuel for 1 hour M (c) Low-water cutoff shunt switch M (d) Auxiliary low-water cut-off (slow drain) M (e) Auxiliary low-water cut-off shunt switch M (f) High-water alarm M (g) Low-water alarm M (h) High-steam pressure cut-out (recycle) 6M (i) High-steam pressure cut-out (non-recycle) 6M (j) Steam safety valves boiler (raise boiler pressure until valve pops) 6M (k) Steam safety valves boiler (accumulation test at high fire) Y (l) Flame scanner M (m) Check gas vent for leaks 6M (n) High-gas fuel pressure cut-off 6M (o) Low-gas fuel pressure cut-off 6M (p) Gas fuel safety shut off valves proof of closure 6M (q) Leak test gas fuel safety shut off valves 6M (t) Low-atomizing pressure for fuel oil 6M (u) High-fuel oil pressure cut-off 6M (v) Low-fuel oil pressure cut-off 6M (w) Fuel oil safety shut off valves proof of closure 6M (x) Leak test fuel oil safety shut off valves 6M (y) Check operation of Liquid Petroleum Gas pilot 6M (z) Low-pilot gas pressure cut-out 6M (aa) Forced draft fan motor interlock 6M (bb) Forced draft fan damper wide open for purge 6M (cc) Boiler outlet damper wide open for purge 6M (dd) Purge air flow interlock 6M (ee) Timing for pre-purge 6M (ff) Timing for post-purge 6M (gg) Igniter timing 6M (hh) Low fire position interlock 6M (ii) Combustion air interlock 6M (jj) Main flame out; i.e., time to close valves 6M (kk) Ignition flame out; i.e., it is time to close valves 6M (ll) Minimum igniter flame test 6M (mm) Scanner not sensing ignition spark 6M (nn) Low-oxygen alarm and/or cut-out 6M (oo) Pre-purge setting of flue gas recirculation damper 6M (pp) Interlock of building outside air damper with burner control 6M (qq) DA Tank and steam line PRV relief valves (6M) (rr) Emergency Stop buttons at exits (ss) Calibrate all flow transmitters (Steam, Gas, Oil, Water) A (tt) Boiler plant exhaust gas sensors 6M (uu) Operation of condensate storage tank high and low water alarms M (vv) DA Tank high and low water alarms (M) (ww) DA Tank make up systems and dump valve (6M) (xx) Steam plant PRV safety valves (A) REFERENCES: a.VHA Boiler Plant Safety Devices Testing Manual, 3rd Edition Dated September 2008 b.VHA Boiler Plant Operations Directive (VHA 2008-062) Dated October 15,2008 c.NFPA 85, Boiler and Combustion Systems Hazard Code d. Boiler Efficiency Manual Boiler Efficiency Institute ® 2002 (Produced for the VA) e.ASME Boiler and Pressure Vessel Code f.Manufacturer's literature - Cleaver-Brooks, Autoflame ®, boiler safety and boiler plant safety devices. g.ASME Test Form for Abbreviated Efficiency Tests CLAUSES FAR NumberTitleDate 52.212-2EVALUATION--COMMERCIAL ITEMSJAN 1999 52.212-3OFFEROR REPRESENTATIONS AND CERTIFICATIONS--COMMERCIAL ITEMSAPR 2012 52.212-4CONTRACT TERMS AND CONDITIONS-- COMMERCIAL ITEMSFEB 2012 52.212-5CONTRACT TERMS AND CONDITIONS REQUIRED TO IMPLEMENT STATUTES OR EXECUTIVE ORDERS--COMMERCIAL ITEMS ALTERNATE II (JUL 2012)AUG 2012 52.217-8OPTION TO EXTEND SERVICESNOV 1999 52.217-9OPTION TO EXTEND THE TERM OF THE CONTRACT--SERVICESMAR 1989 52.219-1SMALL BUSINESS PROGRAM REPRESENTATIONSAPR 2012 52.219-28POST-AWARD SMALL BUSINESS PROGRAM REREPRESENTATIONAPR 2012 FAR Number 52.219-6 52.219-14Title NOTICE OF TOTAL SMALL BUSINESS SET-ASIDE LIMITATIONS ON SUBCONTRACTINGDate NOV 2011 NOV 2011 52.225-25PROHIBITION ON CONTRACTING WITH ENTITIES ENGAGING IN SANCTIONED ACTIVITIES RELATING TO IRAN-- REPRESENTATION AND CERTIFICATIONNOV 2011 52.228-5INSURANCE--WORK ON A GOVERNMENT INSTALLATIONJAN 1997 52.232-18AVAILABILITY OF FUNDSAPR 1984 52.233-2SERVICE OF PROTESTSEP 2006 52.233-3PROTEST AFTER AWARDAUG 1996 852.203-70COMMERCIAL ADVERTISINGJAN 2008 852.233-70PROTEST CONTENT/ALTERNATIVE DISPUTE RESOLUTIONJAN 2008 852.233-71ALTERNATE PROTEST PROCEDURE (MAY 2010) NOTEMAY 2010 852.237-70CONTRACTOR RESPONSIBILITIESAPR 1984 852.232-72ELECTRONIC SUBMISSION OF PAYMENT REQUESTSNOV 2012
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/NaVAMC/VAMCCO80220/VA24915R0061/listing.html)
 
Document(s)
Attachment
 
File Name: VA249-15-R-0061 VA249-15-R-0061.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1706320&FileName=VA249-15-R-0061-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1706320&FileName=VA249-15-R-0061-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: 1310 24th Ave South;Nashville TN 37212;3400 Lebanon Pike;Murfreesboro TN
Zip Code: 37129
 
Record
SN03562052-W 20141101/141031000017-f7a1dd50488d7125265ee9ddf0fe1f83 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.