Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JULY 24, 2014 FBO #4625
DOCUMENT

J -- Emergency Generator Maintenance Service - Attachment

Notice Date
7/22/2014
 
Notice Type
Attachment
 
NAICS
811310 — Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
 
Contracting Office
Department of Veterans Affairs;VISN17 Network Contracting Activity;7400 Merton Minter Blvd. (10N17/90C);San Antonio TX 78229
 
ZIP Code
78229
 
Solicitation Number
VA25714Q1414
 
Response Due
7/29/2014
 
Archive Date
8/18/2014
 
Point of Contact
Eugene M. Hanley
 
E-Mail Address
Contracting Officer
(eugene.hanley@va.gov)
 
Small Business Set-Aside
N/A
 
Description
Emergency Generator Maintenance Service Contractor to provide as part of the firm-fixed price Contract/PO all labor, equipment, tools, materials, parts, supplies, software, transportation, supervision, and any other items and services necessary to accomplish the inspection and service described herein. Scope of Work: Scope of Work: Contractor shall perform 3 quarterly inspections, PM Level 1, in accordance with manufacture's recommendations and accepted industry standards on each of the following, Caterpillar 600 KW diesel powered standby generator, Onan 230 KW diesel powered standby generator, Generac, model SD500 diesel powered standby generator, WisperWatt 125 KW portable standby generator. Contractor shall perform 1 annual inspection PM level 2 in accordance with manufacture's recommendations and accepted industry standards on each of the following generator's, Caterpillar 600 KW diesel powered standby generator, Onan 230 KW diesel powered standby generator, Generac, model SD500 diesel powered standby generator, WisperWatt 125 KW portable standby generator. Contractor shall conduct the annual inspection during the Apr-May-June Quarter. Contractor shall perform 1 annual load bank test (2-hour resistive type) on the following generators, Caterpillar 600 KW diesel powered standby generator(This generator shall require a standby generator to be on site), Onan 230 KW diesel powered standby generator, Generac, model SD500 diesel powered standby generator, WisperWatt 125 KW portable standby generator. Contractor shall replace belts, hoses, and wiring as needed. Contractor shall top off all fluids (coolant, batteries, oil) when inspections are done for all PM checks. Contractor shall perform 8 automatic transfer switch inspections.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VASTHCS/VASTHCS/VA25714Q1414/listing.html)
 
Document(s)
Attachment
 
File Name: VA257-14-Q-1414 VA257-14-Q-1414_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1516074&FileName=VA257-14-Q-1414-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1516074&FileName=VA257-14-Q-1414-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: South Texas Veterans Health Care System;3600 Memorial Blvd;Kerrville, Texas
Zip Code: 76504-7451
 
Record
SN03432931-W 20140724/140722234731-6e07291a2ee464c4f80fa66231a31028 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.