DOCUMENT
65 -- Continuous Glucose Monitoring System KC - Attachment
- Notice Date
- 8/15/2013
- Notice Type
- Attachment
- NAICS
- 334510
— Electromedical and Electrotherapeutic Apparatus Manufacturing
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office (NCO) 15;3450 S 4th Street;Leavenworth KS 66048
- ZIP Code
- 66048
- Solicitation Number
- VA25513Q1317
- Response Due
- 8/19/2013
- Archive Date
- 11/17/2013
- Point of Contact
- Penny Capps
- Small Business Set-Aside
- N/A
- Description
- Statement of Work CONTINOUS GLUCOSE MONITORING SYSTEM Kansas City MO VAMC is in need of four Professional Continuous Glucose Monitoring (CGM) Systems. This system is designed to provide the patient and provider with "blinded" glucose data over a three to seven day period. The device is small, light, watertight and simple for the patient to use. Device Features: "Minimal patient training required as there is no monitor "No computer required for set-up "Convenient to wear, discreet and watertight "No alarms for patient to manage "4 finger-sticks per day and logbook only required "Fast data upload via USB connection "Easy access to web-based data visualization program Device Specifications: Atmospheric pressure range57.6kPa - 106kPa (16,000 to -1,300 feet [4,880 to -400 meters] elevation) Dock: 62kPa - 106kPa (13,000 to -1,300 feet [3,965 to -400 meters] elevation) BiocompatibilityComplies with ISO 10993-1 for long-term body contact Operating Conditionstemperature: +23 ° to +113 °F (-5 ° to 45 °C) relative humidity: 5% to 95% with no condensation Dock temperature: +23 ° to +113 °F (-5 ° to +45 °C) Dock relative humidity: 5% to 95% with no condensation Storage Conditionstemperature: -13 ° to +131 °F (-25 ° to +55 °C) relative humidity: 10% to 100% with no condensation Dock temperature: -13 ° to +131 °F (-25 ° to +55 °C) Dock relative humidity: 10% to 100% with no condensation Battery Life7 days of continuous glucose monitoring (CGM) immediately following a full charge, plus 10 days of additional battery life immediately following a CGM study. Any data on the device will be lost when the battery loses its charge. Dimensions and WeightWidth: 1.4 inches (3.5 centimeters) Length: 1.1 inches (2.8 centimeters) Height: 0.4 inches (0.9 centimeters) Weight: 0.2 ounces (5.7 grams) Dock Dimensions and WeightWidth: 2 inches (5.1 centimeters) Length: 2.5 inches (6.4 centimeters) Height: 1.1 inches (2.8 centimeters) Weight: 0.8 ounces (22.7 grams) All components need to be compatible and ready to be connected for use for patient care. The vendor will oversee all training for the end user, if required. The Contractor's field service employee, if needed, shall wear visible identification at all times while on the premises of the VA Medical Center. Smoking is not prohibited inside the buildings. Possession of weapons is prohibited. Enclosed containers, including tool kits, shall be subject to search. Violations of the VA regulations may result in citation answerable in the United States (Federal) District Court.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/LeVAMC/VAMCKS/VA25513Q1317/listing.html)
- Document(s)
- Attachment
- File Name: VA255-13-Q-1317 VA255-13-Q-1317_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=948404&FileName=VA255-13-Q-1317-001.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=948404&FileName=VA255-13-Q-1317-001.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA255-13-Q-1317 VA255-13-Q-1317_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=948404&FileName=VA255-13-Q-1317-001.docx)
- Record
- SN03151549-W 20130817/130816000704-16947789876af7451bf36cc5541ea68c (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |