Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MAY 03, 2012 FBO #3813
SOLICITATION NOTICE

54 -- Two (2) Courtesy Docks for Tiber Reservoir

Notice Date
5/1/2012
 
Notice Type
Presolicitation
 
Contracting Office
Bureau of Reclamation - GP - MTAO PO Box 30137 Billings MT 59107
 
ZIP Code
59107
 
Solicitation Number
R12PS60231
 
Response Due
5/12/2012
 
Archive Date
5/1/2013
 
Point of Contact
Brian O'Boyle Contract Specialist 4062477351 boboyle@usbr.gov;
 
E-Mail Address
Point of Contact above, or if none listed, contact the IDEAS EC HELP DESK for assistance
(EC_helpdesk@NBC.GOV)
 
Small Business Set-Aside
Total Small Business
 
Description
The Bureau of Reclamation - Great Plains (GP) Region - Montana Area Office is issuing a solicitation and subsequently a Firm Fixed Price purchase order for two (2) Courtesy Docks as described in the Statement of Work (SOW) for delivery and installation at the VFW Campground on Tiber Reservoir in Montana. Requirements:CLIN 0001 - Rolling and Floating Courtesy Dock; Quantity 2 EA. Specifications:The Courtesy Boat Dock shall meet or exceed the following specifications: 1. Floating and rolling dock that can easily be put into the water and removed using a ton pickup with a standard ball hitch. 2. Length - 60 ft. 3. Width - 8 ft. 4. Dock shall be capable of withstanding winds of at least 50 MPH from any direction and the accompanying wave action with minimal deflection of dock both horizontally and vertically. A flow-through design shall be used to reduce wave impact and wind resistance. 5. The approach ramp shall be continuous across the entire width of the dock, shall be hinged, and be capable of being removed easily for moving the dock. The ramp shall be level side-to-side and with water fluctuations capable of self-maintaining on a boat ramp slope of 1:12 or less to accommodate handicap use. The ramp hinge shall intersect the top of the dock decking and produce a maximum -inch gap between ramp and dock deck. 6. The floating dock system including approach ramp shall be capable of being moved out of water without the need to pull anchors, unhook cables, remove driven posts, etc. The dock system shall be designed without the need for fixed anchors in the lake bottom or shoreline. The dock shall be self-anchoring and self-aligning whenever it is moved. 7. The dock carrier frame and rollers shall be capable of moving over uneven and rocky lake bottom and anchor the dock without creating any side slope on floating units. 8. The dock carrier shall be capable of supporting the entire floating unit for winter removal and storage on-site. 9. The dead load - shall be the entire weight of the floating units and all equipment called for in the plans and specifications. 10. The live load - structural load for dock and ramp shall be 50 lbs P.S.F minimum. Deck surface - concentrated 300 lbs plus 33% impact total (400 lbs) applied over an area 12' x 12'. Uniform 50 P.S.F. Flotation of 30 lbs P.S.F. Deflection of ramp and deck to be a maximum of 1/180. 11. Shall provide sufficient built-in torsion resistance to positively prevent torsion, racking, and twisting by no more than 3 inches of variation in normal free board of the free end of all deck units under normal load. 12. All floating units shall have a structural steel frame of welded construction to which the floatation, decking, and guides are attached. Metal frame shall be powder coated a grey tone as approved by Reclamation. 13. The flotation units shall consist of a rectangular-shaped polyethylene case filled with formed-in-place polystyrene sealed so as to protect the foam from all sides. These units shall be placed within the protected areas of the unit so as to prevent any impact from vessels or persons. Flotation freeboard under dead load shall be 12-inches minimum. Freeboard under dead load and a live load of 30 pounds per square foot shall not be less than 8 inches. 14. The decking shall consist of 2"x 6" composite decking material placed perpendicular to the line of travel and fastened with at least two screws at each structural cross support and countersunk so the heads are slightly beneath the board surface. Gaps between boards shall not exceed -inch. 15. The connections between floating units shall be flexible and capable of transmitting all loads and forces imposed upon the units. Connection shall not protrude above the level of the deck nor produce more than a -inch gap between decking planks. 16. Each floating unit shall have rub rails of 2" x 6" composite decking material and a round metal pipe bull or bumper rail mounted 3-inches above the deck. These rub and bumper rails shall be on each longitudinal side. The terminal floating unit shall have both rails mounted also on its outside end. 17. The dock shall have a rolling anchor frame with a knee joint that allows for fluctuation of up to 18 ft. as water level rises and lowers without movement of the dock. 18. Warranty:(a) The dock system shall have a 3 year warranty on all workmanship, structural components, decking, and flotation. (b) The floats shall have a 100% non -prorated warranty for a minimum of 8 years against sinking, cracking, fragmenting, or loosing beads. 19. The entire dock system shall be delivered and installed at VFW Campground on Tiber Reservoir. Delivery:F.O.B Destination The associated North American Industrial Classification System (NAICS) code for this procurement is 237990 with a small business size standard of $33.5 Million. This requirement is a 100% small business set-aside and only qualified quoters may submit quotes. All responsible sources may submit a bid, proposal, or quotation which shall be considered by the agency. The solicitation and any subsequent amendments will be posted to the www.FedBizOpps.gov; prospective quoters are responsible for downloading their own copy of the solicitation from this website and for frequently monitoring that site for any amendments. The Government is not responsible for any inability of the quoter to access the posted documents. No telephone or fax requests will be accepted, and no hard-copy solicitation/amendment will be mailed or faxed. The solicitation shall be posted on or about 02 May 2012 with a response date of on or about 12 May 2012. The buyer will NOT provide a hard copy of the Solicitation package. Quoter must be registered in the Central Contractor Registration (CCR) database before an award can be made to them. If the quoter is not registered in the CCR, it may do so through the CCR website at http://www.ccr.gov. Point of Contact: Brian O'Boyle, Contract Specialist, Bureau of Reclamation - GP Region, Phone (406) 247-7351, Email boboyle@usbr.gov.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/9089b8716337617ed22140929951c5d2)
 
Place of Performance
Address: The Contractor shall deliver and install the required courtesy docks at the VFW Campground located at Tiber Reservoir near Chester, MT.
Zip Code: 59522
 
Record
SN02736004-W 20120503/120502000115-9089b8716337617ed22140929951c5d2 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.