Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF APRIL 06, 2012 FBO #3786
DOCUMENT

H -- Life Safety Code Evaluation - Attachment

Notice Date
4/4/2012
 
Notice Type
Attachment
 
NAICS
541350 — Building Inspection Services
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office;NCO 19;4100 E. Mississippi Avenue, Suite 900;Glendale CO 80246
 
ZIP Code
80246
 
Solicitation Number
VA25912R0321
 
Response Due
4/16/2012
 
Archive Date
4/21/2012
 
Point of Contact
Aldo Fred Girany
 
E-Mail Address
irany@va.gov<br
 
Small Business Set-Aside
N/A
 
Description
Statement of Work Conduct a fire and life safety assessment of the Cheyenne VAMC and prepare required Joint Commission Statement of Conditions eSOC and paper documentation. The survey will include the main hospital facility, approximately 311,700 sq. ft., the warehouse Building, approximately 6100 square feet, Boiler Building, approximately 8000 square feet and the Electrical Distribution Building, approximately 600 square feet. As a minimum, the scope of services to include the following: 1.Conduct a survey of the Buildings in order to determine compliance with the 2012 edition of NFPA 101, Life Safety Code and Joint Commission. This survey will be used for the 2013 JCOPH certification. 2.Provide recommendations for the appropriate occupancy classification for each section of each building. 3.Conduct a random survey of fire and smoke barrier walls above the accessible ceilings. On redlined drawings, denote wall deficiencies noted for future repair. 4.While on-site, review the existing electronic Joint Commission data and assist in its update. 5.At the completion of the site survey, provide an exit conference with Chief of Facilities Management, Safety Manager, and Senior Leadership staff to discuss findings. 6.The following data shall be presented in a usable format of Microsoft Word, Excel or Access. A.General Building description including height, size, construction classification and occupancy. B.Information provided by the medical center regarding any equivalencies approved by the Joint Commission (if any). C.Small scale floor plan drawings showing the occupancy classification for each area. Also identify hazardous rooms and key note any special life safety features. The hospital will provide a CD containing the current electronic drawing files (in AutoCAD) and current fire and smoke barrier wall arrangements for review and re-plotting prior to the site survey. D.Recommendations on how to correct any non-compliant items that are not correctable by normal construction methods. E.Deviations from NFPA 101 and/or The Joint Commission Standards will be identified and listed by type. All deviations must reference the specific NFPA 101 section and/or The Joint Commission Standard Number. F.Prepare a preliminary Plan For Improvement (PFI) in the draft submittal for any items that are not correctable as normal punch list items. After receiving the medical center's input, complete the PFI for inclusion in the final SOC documents. 7.Three copies of the SOC documents will be submitted for review. 8.Provide 2 hard copies and 1 soft copy of the final draft and 1 computer CD containing the final SOC documents and drawings. 9.Minor deficiency lists shall be submitted within 2 weeks after completion of the site survey. Final documentation shall be prepared within two weeks after receipt of the final review comments. 10.The intent of this project is to receive a high quality SOC report, update the Fire Protection Features Drawings to reflect current healthcare provisions and PFI assistance using a standard Microsoft Word, Excel or Access format for the utilization of information (subject to VA approval). Survey will be conducted by the Safety Manager and a representative of the contractor's office experienced in the Life Safety Code and the Joint Commission SOC/PFI process.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VARMCCC/VARMCCC/VA25912R0321/listing.html)
 
Document(s)
Attachment
 
File Name: VA259-12-R-0321 VA259-12-R-0321_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=317700&FileName=VA259-12-R-0321-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=317700&FileName=VA259-12-R-0321-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN02713459-W 20120406/120404234751-5db8c9a7696165ce6893166d691ebf34 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.