Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF FEBRUARY 26, 2012 FBO #3746
MODIFICATION

58 -- 58--Sources Sought for Additional Sources for High Power Amplifier AM-7498/G

Notice Date
2/24/2012
 
Notice Type
Modification/Amendment
 
Contracting Office
ACC-APG - Aberdeen Division B, HQ CECOM CONTRACTING CENTER, 6001 COMBAT DRIVE, ABERDEEN PROVING GROU, MD 21005-1846
 
ZIP Code
21005-1846
 
Solicitation Number
MARKET-SURVEY-5212-1
 
Response Due
2/28/2012
 
Archive Date
4/28/2012
 
Point of Contact
Tineka C. Davis, 443-861-5438
 
E-Mail Address
ACC-APG - Aberdeen Division B
(tineka.c.davis.civ@mail.mil)
 
Small Business Set-Aside
N/A
 
Description
FOR ALL INFORMATION PLEASE CONTACT: Susan Tyndall, AMSRD-RDER-PRC-ED susan.tyndall@us.army.mil (443) 395-7013 This is a modification to the previous MARKET-SURVEY-5212-1 to include the updated estimated total quantity of units the Army will be procuring for this contract. This is a Market Survey to identify additional manufacturers/vendors to qualify as Approved Sources of Supply for High Power Amplifier (HPA) AM-7498/G and some of its subassemblies (except the 2.5kW TWT) via a five (5) year Indefinite Delivery, Indefinite Quantity (IDIQ) Flexible Long Term Contract (FLTC). The HPA is used on the military's SATCOM Terminals AN/FSC-78C (Heavy), AN/GSC-39C (Medium) and AN/GSC-52A (SAMT). Currently the only Approved Source of Supply for the HPA and its subassemblies is MCL, Inc., Bolingbrook, IL (CAGE Code 16469). The assemblies being considered for procurement are: ITEMNSN CECOM PART NUMBERMCL, INC. PART NUMBERESTIMATED TOTAL QTY (subject to change) HPA AM-7498/G5996-01-380-8262A3187818-001300300 TWTA AM-7499/G5996-01-380-8266A3187818-101154170 HVPS PP-8380/G6130-01-381-0959A3187818-102154180 C/S CABLE ASSY5995-01-426-3235A3187818-10403C3425-12017 PRIME PWR MODULE6130-01-407-6163A3187818-30113164-2080 FET BRIDGE ASSY5996-01-420-1296A3187818-3021316516 HV TANK ASSY6110-01-417-8473A3187818-303131630 LOGIC PWR SUPPLY6130-01-431-3273A3187818-304C15418-04012 HVPS BLOWER ASSY4140-01-414-6658A3187818-305D15418-0300 CONTROL DISPLAY ASSY5895-01-414-0676A3187818-306201004 CDA BASE CCA5998-01-425-5603A3187818-308D167380 CDA MAIN CCA5998-01-432-5064A3187818-309D167390 CDA LOCAL INTRFC CCA5998-01-426-3240A3187818-310D167405 CTRL & REG CCA5998-01-426-3239A3187818-313D167430 IPA ASSY5998-01-417-8468A3187818-402C15417-02021 ANODE SWITCH ASSY5895-01-417-8469A3187818-403C15417-05566 TWTA BLOWER ASSY4140-01-414-4138A3187818-404C15417-0303 OUTPUT WAVEGUIDE ASSY5985-01-424-6808A3187818-40627D296718 ARC DECTECTOR CCA5998-01-414-4135A3187818-407C1673126 RF SSA5996-01-428-9075A3187818-41127C305351 Interested manufacturers/vendors should understand that any of these items supplied must be form, fit and functional equivalents of and be completely interchangeable with items supplied by MCL, Inc. Manufacturers/vendors not currently qualified as Approved Sources of Supply will also be required to qualify their product(s) via the First Article Test (FAT) requirements stipulated in CECOM Source Control Drawing A3187818 upon contract award. The above items are described in Source Control Drawing A3187818, however, detailed functional and interface requirements for the subassemblies are proprietary to MCL, Inc, and are therefore, not available. We will NOT consider replacing the entire HPA since it will be replaced by the new Modernization of Enterprise Terminals program which will eventually replace all strategic SATCOM terminals. Suppliers interested in providing any or all of the above items must so indicate by writing to Commander, U.S. Army CECOM LCMC, ATTN: AMSRD-RDER-PRC-ED, Building 6007 3rd floor, Aberdeen Proving Ground, MD 21005. The response must include documentation such as test results, copies of purchase orders if the manufacturer/vendor previously produced any of the items for MCL, Inc., or a statement from MCL, Inc., certifying that the manufacturer/vendor can, in fact, produce items which will be physically and functionally interchangeable with items from MCL, Inc. Prospective manufacturers/vendors may be required to warrant that items they supply will perform satisfactorily when used in the intended application by the military. This Market Survey does not guarantee a contract by the Government. For more information, contact Susan Tyndall, preferably via email at susan.tyndall@us.army.mil or phone (443) 395-7013. Responses must be received no later than February 28, 2012.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/14b2b416043e407ee2c0af5933d397a6)
 
Place of Performance
Address: ACC-APG - Aberdeen Division B HQ CECOM CONTRACTING CENTER, 6001 COMBAT DRIVE ABERDEEN PROVING GROU MD
Zip Code: 21005-1846
 
Record
SN02682596-W 20120226/120224234937-14b2b416043e407ee2c0af5933d397a6 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.