Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF DECEMBER 17, 2011 FBO #3675
SOURCES SOUGHT

Y -- Sources Sought for Design and Construction of a New Electro-Dialysis Water Treatment Facility and Water Supply and Distribution System Infrastructure Upgrades, Fort Irwin, CA

Notice Date
12/15/2011
 
Notice Type
Sources Sought
 
NAICS
221310 — Water Supply and Irrigation Systems
 
Contracting Office
USACE District, Los Angeles, P.O. Box 532711, Los Angeles, CA 90053-2325
 
ZIP Code
90053-2325
 
Solicitation Number
W912PL-12-S-0003
 
Response Due
1/17/2012
 
Archive Date
3/17/2012
 
Point of Contact
lucia.a.carvajal, 213-452-3240
 
E-Mail Address
USACE District, Los Angeles
(lucia.a.carvajal@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
Market Research and Sources Sought Notice for information on capability and availability of potential contractors to perform design and construction services for a new Electro-Dialysis Reversal (EDR) Water Treatment Facility and water supply and distribution system infrastructure upgrades at Ft. Irwin, California. This is a SOURCES SOUGHT SYNOPSIS and is not a solicitation announcement. The purpose of this Market Research and Sources Sought Notice is to gain knowledge of potential qualified firms, including Small Businesses, Hubzone, 8(a) and Service Disabled Veteran owned firms. Responses to this Sources Sought Synopsis will be used by the government in making appropriate acquisition decisions. The U.S. Army Corps of Engineers, Los Angeles District, anticipates a future procurement for the EDR water treatment and system design and construction activities including but not limited to the Design Build of a 6.0 million gallons per day (MGD) EDR water treatment plant. The Plant will treat all contaminants found in Fort Irwin's ground water in accordance with (IAW) federal and state requirements (i.e.: arsenic, fluoride, and total dissolved solids). The Plant will include an Electro-Dialysis Reversal (EDR) system as primary treatment. The project also includes the construction of the EDR facility with pumps, EDR stacks, filters, and an EDR waste equalization tank. The Plant also includes treatment of the waste stream to achieve 99.8% potable water recovery rate with reject discharge to evaporation ponds. Construction also includes a 1 million gallon (MG) pretreatment tank and a 1 MG clear well tank. Project also includes control building, chemical building, treated water pump station, process drain pump station, standby generator, process piping, and SCADA. The project includes supporting utilities and infrastructure upgrades to the water plant include electric service, site improvements, communications, water, sewer, gas, storm water drainage and antiterrorism measures. Commissioning of the water treatment plant is also included. The water system improvements include pipelines connecting the water plant to Bicycle Lake booster station, replacement of expired pipe and equipment, and water supply /distribution system expansion. Other system improvements include improvement of fire flow, installation of a new water well at Langford Lake and connecting Irwin basin wells to raw water transmission lines. Tank construction includes rehabilitation of existing welded steel water storage tanks and repair/replacement of a 1 MG above ground water storage tank. Sustainable Design and Development (SDD), Energy Independence and Security Act (EISA) of 2007, and Energy Policy Act of 2005 (EPAct05) features will be included. The PA for this project is $115M. The cost of design and construction for this project ranges from $100-$250M. The proposed project duration is 36 months. Sources are being sought for firms with a North American Industry Classification System (NAICS) Code of 221310. Responses are requested with the following information, which shall not exceed a total of eight pages. 1. Offerors' name, address, points of contact with telephone numbers and e-mail addresses. 2. Business size/classification to include any designations as Small Business, HUBZone, Service Disabled Veteran Owned, or 8(a) and NAICS code designations shall be indicated on first page of submission. 3. Bonding capability (construction bonding level per single contract and aggregate construction bonding level, both expressed in dollars; along with current available bonding capacity). 4. Description of capability to perform the proposed design and construction, manage subcontractors, prepare and comply with various environmental and construction permits (including California), and capacity to execute this project with other ongoing construction contracts. 5. Past performance/experience on projects of similar scope and magnitude, describing no more than five (5) projects that are at least 50% construction complete within the past six years. The past performance information should include project title, location, general description of the construction to demonstrate relevance to the proposed project, the Offerors' role, the designer A/E firm (if design build), dollar value of contract, whether certified or registered as a LEED project (and applicable LEED rating), and name of the company, agency or government entity for which the work was performed with contact information (reference name, phone number and e-mail address). Responses should be submitted to Lucy Carvajal, Contract Specialist. Mail submittals or send overnight courier to U.S. Army Corps of Engineers, Los Angeles District, Contracting Division, c/o Lucy Carvajal, 915 Wilshire Blvd., Los Angeles, CA 90017. Submittals are due no later than 17 January 2012. Submittals will not be returned. Telephonic responses will not be honored. This is not a Request for Proposal, only a Request for Information. No award will result from this Sources Sought. This notice does not constitute any commitment by the Government.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA09/W912PL-12-S-0003/listing.html)
 
Place of Performance
Address: USACE District, Los Angeles P.O. Box 532711, Los Angeles CA
Zip Code: 90053-2325
 
Record
SN02639705-W 20111217/111215234125-e0d8b21f355ccce090df18aec6698bcc (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.