Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF SEPTEMBER 11, 2011 FBO #3578
SOLICITATION NOTICE

83 -- Tentage

Notice Date
9/9/2011
 
Notice Type
Combined Synopsis/Solicitation
 
Contracting Office
976 William H. Wilson Ave, Fort Stewart, GA 31314
 
ZIP Code
31314
 
Solicitation Number
0010092202
 
Response Due
9/16/2011
 
Archive Date
3/14/2012
 
Point of Contact
Name: Client Services, Title: Sourcing Agent, Phone: 1.877.9FEDBID, Fax: 703.442.7822
 
E-Mail Address
clientservices@fedbid.com;
 
Small Business Set-Aside
N/A
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, in conjunction with FAR 13.5, as applicable, and as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; bids are being requested and a written solicitation will not be issued.The solicitation number is 0010092202 and is issued as an invitation for bids (IFB), unless otherwise indicated herein.The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-53. The associated North American Industrial Classification System (NAICS) code for this procurement is 314912 with a small business size standard of 500.00 employees.This requirement is unrestricted and only qualified offerors may submit bids.The solicitation pricing on www.FedBid.com will start on the date this solicitation is posted and will end on 2011-09-16 15:30:00.0 Eastern Time or as otherwise displayed at www.FedBid.com.FOB Destination shall be Fort Stewart, GA 31314 The U.S. Army ACC MICC Fort Stewart requires the following items, Brand Name or Equal, to the following: LI 001, BASE X SHELTER 103, 9.5' X 15' Salient Characteristics: Tentage usable area minimum of 142 square feet; material must be operable in temperatures ranging from -50 degrees Fahrenheit to +131 degrees Fahrenheit and come with five year warranty. Tent used as an entry point for the TOC. Color Tan only., 7, EA; LI 002, BASE X SHELTER 105, 9.5' X 25'Salient Characteristics: Tentage usable area minimum of 237 square feet; material must be operable in temperatures rangingfrom -50 degrees Fahrenheit to +131 degrees Fahrenheit and come with a five year warranty. Tent used as an entry point for the TOC. Color Tan only., 2, EA; LI 003, BASE X SHELTER 203, 14' X 15' Salient Characteristics: Tentage usable area minimum of 210 square feet; material must be operable in temperatures ranging from -50 degrees Fahrenheit to +131 degrees Fahrenheit and come with a five year warranty. Tent used as a Command and Control (C2)area. Color Tan only., 2, EA; LI 004, BASE X SHELTER 205, 14' X 25' COLOR TAN ONLY. Salient Characteristics: Mid-sized shelter with a clear span of 14? with 6 entry and egress points that will house 12-14 personnel.Clear interior span of 14' x 25ft6 entry and egress pointsElectrical outlet every 5'Hang points every 5' bear 100-pound weight-load eachIntegral liner with floor and HVAC plenumMid-size shelter to house 12 to 14 personnelLow weight, cube and personnel requirementsEasy field maintenanceEnergy efficientSuperior strength and durability, 1, EA; LI 005, BASE X SHELTER 307, 18' X 35' Salient Characteristics:Tentage usable area minimum of 630 square feet; material must be operable in temperatures ranging from -50 degrees Fahrenheit to +131 degrees Fahrenheit and come with a five year warranty. Color Tan only., 7, EA; LI 006, ECU, 6 TON BASIC, 3' DUCTS, TAN Salient Characteristics:Trailer minimum cargo volume of 106 cubic feet, includes a minimum of 16 gallon fuel tank and comes with an a minimum of 18 KW Generator Set and minimum of 6 Ton Environmental Control Unit., 11, EA; LI 007, TRAILER SUPPORT SHELTER W/WHEEL AND TONGUE Salient Characteristics: Trailer minimum cargo volume of 106 cubic feet, includes a minimum of 16 gallon fuel tank and comes with an a minimum of 18 KW Generator Set and minimum of 6 Ton Environmental Control Unit., 4, EA; LI 008, BOOT, CONNECTOR, END TO END, TAN Salient Characteristics:Boot connector end to end; material must be operable in temperatures ranging from -50 degrees Fahrenheit to +131 degrees Fahrenheit and come with a five year warranty. ColorTan only., 9, EA; LI 009, BOOT CONNECTOR, SIDE TO SIDE COLOR TAN ONLY. Salient Characteristics:Boot connector side to side; material must be operable in temperatures ranging from -50 degrees Fahrenheit to +131 degrees Fahrenheit and come with a five year warranty. ColorTan only., 2, EA; LI 010, BOOT CONNECTOR,SIDE TO END COLOR TAN ONLY. Salient Characteristics:Boot connector side to side; material must be operable in temperatures ranging from -50 degrees Fahrenheit to +131 degrees Fahrenheit and come with a five year warranty. ColorTan only., 8, EA; LI 011, BOOT, OPEN END, 300 SERIES, TAN Salient Characteristics:Tentage boot end door designed to fit shelter door; material must be operable in temperatures ranging from -50 degrees Fahrenheit to +131 degrees Fahrenheit and come with a five year warranty. Color Tan only., 1, EA; LI 012, VESTIBULE, BLACKOUT, TAN Salient Characteristics:Vestibule Blackout; material must be operable in temperatures ranging from -50 degrees Fahrenheit to +131 degrees Fahrenheit and come with a five year warranty. ColorTan only., 1, EA; LI 013, KIT, LIGHT, WITH TRANSIT CASE (SET OF 8) Salient Characteristics:Light sets with transit consisting of a minimum of eight lights per set; material must be operable in temperatures ranging from -50 degrees Fahrenheit to +131 degrees Fahrenheit and come with a five year warranty. Color Tan only., 10, EA; LI 014, FLOORING READY FOLD, BASE-X, 203 GREY Salient Characteristics: Rigid flooring to cover tent floor., 2, EA; LI 015, FLOORING READY FOLD, BASE-X, 205 GREY Salient Characteristics: Rigid flooring to cover tent floor., 1, EA; LI 016, FLOORING,READY FOLD,BASE-X 307, GREY Salient Characteristics: Rigid flooring to cover tent floor., 7, EA; LI 017, RADIANT BARRIER BLANKET, TEMPSHIELD, 203 Salient Charcterictics: Should work with the HDT Base X Shelters.Be superior radiant/insulative retardant for conductive, convective and radint heat transfer.Retards vapor diffusion through the shelter walls.Constructed with nontoxic and non-carcinogenic materials.Puncture and tear resistant,Does not promote growth., 2, EA; LI 018, RADIANT BARRIER BLANKET, TEMPSHIELD, 307 Salient Charcterictics: Should work with the HDT Base X Shelters.Be superior radiant/insulative retardant for conductive, convective and radint heat transfer.Retards vapor diffusion through the shelter walls.Constructed with nontoxic and non-carcinogenic materials.Puncture and tear resistant,Does not promote growth., 7, EA; LI 019, TABLE,C2,FOLDING LEGS, BLACK,5'x24",Qty 2 in Bag Salient Characteristics: Robust and durable Independently adjusting legs for uneven surfacesOuter ABS shell bonded to internal wood laminate and featuring high-impact corners.Able to support up to 1600 lbs.Each leg is individually adjustable for unleveled conditions12 year warranty, 44, EA; LI 020, CHAIR, C2, FOLDING, BLACK, (4 in Bag) Salient Characteristics: Durable hardened polypropylene plasticCompact and sold as a set of 4 Able to support up to 800 lbs12 year warranty, 41, EA; LI 021, SMART BAG, C2, w/36"L 12-outlet power strip, Black Salient Characteristics: Durable soft shell bag capable of attaching to the front of the C2 table.Can support up to 50 lbs.Bag has a 12-outlet power strip,individualizedvelcro pockets to run network and video cables and allowsfor separation of SIPR and NIPR networks., 6, EA; LI 022, TABLE, C2, FOLDING LEGS, 5'x24", BLACK (set of 2) Salient Characteristics: Robust and durable Independently adjusting legs for uneven surfacesOuter ABS shell bonded to internal wood laminate and featuring high-impact corners.Able to support up to 1600 lbs.Each leg is individually adjustable for unleveled conditions12 year warranty, 3, EA; LI 023, Video Display System, w/Projector, 40"x52" screen Salient Characteristics: Adaptable for expeditionary environments.Lighter and faster set-up than overhead framesystems; weighs only 88 lbs.Free-standing screen and projector device thatare less than 26 in. (66 cm) apart.Conserves scarce floor space.Model has 40 x 52in diagonal screen., 2, EA; LI 024, Visual Display System, w/ Projector & Edge, 1, EA; LI 025, Visual Display System - Digital Control Unit 16x16, Salient Characteristics: Controls audio and visual feeds.Quad-screen capable.Unit contained in a shock-mounted transport case, all cables and modules to expand system capabilities.Customized to support specific mission requirements., 1, EA; LI 026, SHELTER AUDIO SYSTEM, 1, EA; LI 027, CABLE MGMT SYS, READY ROLL, TEN 48" SECTIONS, BLACK Salient Characteristics:Flooring Sheet Modular require 4,567 sq ft. plastic modular hard flooring with perforated traction surface, anti-static treated, top access cable points per 48x42 square feet. Require four cable trays to safely secure excess cable. And, one cable management system to easily ready roll cable out when required., 1, EA; LI 028, INSTALLATION: Base-X Technician Labor Hour, 8, EA; LI 029, CABLE EXTENSION, POWER, 25' Salient Characteristics: Capable of extended power throughout tent.Black in color., 2, EA; LI 030, CABLE EXTENSION, POWER, 50' Salient Characteristics: Capable of extended power throughout tent.Black in color., 1, EA; LI 031, CABLE PATCH, CAT5, RED, 3' Salient Characteristics: Reusable managed cable.Eliminates an individual CAT5 cable leading from the table to the DCU for each individual user.One managed cable can support any combination and up to six video, data, audio or telephone feeds through the use of a Jack Pack.Aids in presenting a neat and professional command center.Can customize cable to desired length.Available in a variety of colors to designate secure and unsecure networks., 40, EA; LI 032, CABLE PATCH, CAT5, RED, 5' Salient Characteristics: Reusable managed cable.Eliminates an individual CAT5 cable leading from the table to the DCU for each individual user.One managed cable can support any combination and up to six video, data, audio or telephone feeds through the use of a Jack Pack.Aids in presenting a neat and professional command center.Can customize cable to desired length.Available in a variety of colors to designate secure and unsecure networks., 28, EA; LI 033, CABLE PATCH, CAT5, RED, 7' Salient Characteristics: Reusable managed cable.Eliminates an individual CAT5 cable leading from the table to the DCU for each individual user.One managed cable can support any combination and up to six video, data, audio or telephone feeds through the use of a Jack Pack.Aids in presenting a neat and professional command center.Can customize cable to desired length.Available in a variety of colors to designate secure and unsecure networks., 2, EA; LI 034, CABLE PATCH, CAT5, RED, 10' Salient Characteristics: Reusable managed cable.Eliminates an individual CAT5 cable leading from the table to the DCU for each individual user.One managed cable can support any combination and up to six video, data, audio or telephone feeds through the use of a Jack Pack.Aids in presenting a neat and professional command center.Can customize cable to desired length.Available in a variety of colors to designate secure and unsecure networks., 7, EA; LI 035, CABLE PATCH, CAT5, RED, 15' Salient Characteristics: Reusable managed cable.Eliminates an individual CAT5 cable leading from the table to the DCU for each individual user.One managed cable can support any combination and up to six video, data, audio or telephone feeds through the use of a Jack Pack.Aids in presenting a neat and professional command center.Can customize cable to desired length.Available in a variety of colors to designate secure and unsecure networks., 4, EA; LI 036, CABLE, TELCO STRAIT TO TELCO RIGHT, 25 PAIR, 25' Salient Characteristics: Reusable managed cable.Eliminates an individual CAT5 cable leading from the table to the DCU for each individual user.One managed cable can support any combination and up to six video, data, audio or telephone feeds through the use of a Jack Pack.Aids in presenting a neat and professional command center.Can customize cable to desired length.Available in a variety of colors to designate secure and unsecure networks., 3, EA; LI 037, CABLE, TELCO STRAIT TO TELCO RIGHT, 25 PAIR, 35' Salient Characteristics: Reusable managed cable.Eliminates an individual CAT5 cable leading from the table to the DCU for each individual user.One managed cable can support any combination and up to six video, data, audio or telephone feeds through the use of a Jack Pack.Aids in presenting a neat and professional command center.Can customize cable to desired length.Available in a variety of colors to designate secure and unsecure networks., 2, EA; LI 038, CABLE, TELCO STRAIT TO TELCO RIGHT, 25 PAIR, 50' Salient Characteristics: Reusable managed cable.Eliminates an individual CAT5 cable leading from the table to the DCU for each individual user.One managed cable can support any combination and up to six video, data, audio or telephone feeds through the use of a Jack Pack.Aids in presenting a neat and professional command center.Can customize cable to desired length.Available in a variety of colors to designate secure and unsecure networks., 2, EA; LI 039, JACK PACK, CAT5/6, 6 PORT, 7, EA; LI 040, TRANSIT CASE, AUDIO/VIDEO, FOR CABLES W/WHEELS Salient Characteristics: Tactical case w/wheels is 31.3L X 20.4W X 12.2H35lbs. packed weight., 2, EA; LI 041, VIDEO RECEIVER, AUDIO, CAT5/6, 2, EA; LI 042, VIDEO TRANSMITTER, AUDIO, CAT5/6, 12, EA; LI 043, SHIPPING, 1, EA; LI 044, CHAIR, C2, FOLDING, BLACK, (4 in Bag) Salient Characteristics: Durable hardened polypropylene plasticCompact and sold as a set of 4 Able to support up to 800 lbs12 year warranty, 3, EA; Solicitation and Buy Attachments ***Question Submission: Interested offerors must submit any questions concerning the solicitation at the earliest time possible to enable the Buyer to respond. Questions must be submitted by using the 'Submit a Question' feature at www.fedbid.com. Questions not received within a reasonable time prior to close of the solicitation may not be considered.*** For this solicitation, U.S. Army ACC MICC Fort Stewart intends to conduct an online competitive reverse auction to be facilitated by the third-party reverse auction provider, FedBid, Inc. FedBid has developed an online, anonymous, browser based application to conduct the reverse auction. An Offeror may submit a series of pricing bids, which descend in price during the specified period of time for the aforementioned reverse auction. U.S. Army ACC MICC Fort Stewart is taking this action in an effort to improve both vendor access and awareness of requests and the agency's ability to gather multiple, competed, real-time bids.All responsible Offerors that respond to this solicitation MUST submit the pricing portion of their bid using the online exchange located at www.FedBid.com. There is no cost to register, review procurement data or make a bid on www.FedBid.com.Offerors that are not currently registered to use www.FedBid.com should proceed to www.FedBid.com to complete their free registration. Offerors that require special considerations or assistance may contact the FedBid Helpdesk at 877-9FEDBID (877-933-3243) or via email at clientservices@fedbid.com. Offerors may not artificially manipulate the price of a transaction on www.FedBid.com by any means. It is unacceptable to place bad faith bids, to use decoys in the www.FedBid.com process or to collude with the intent or effect of hampering the competitive www.FedBid.com process.Should offerors require additional clarification, notify the point of contact or FedBid at 877-9FEDBID (877-933-3243) or clientservices@fedbid.com.Use of FedBid: Buyers and Sellers agree to conduct this transaction through FedBid in compliance with the FedBid Terms of Use. Failure to comply with the below terms and conditions may result in offer being determined as non-responsive. The selected Offeror must comply with the following commercial item terms and conditions. FAR 52.212-1, Instructions to Offerors - Commercial, applies to this acquisition. The selected Offeror must submit a completed copy of the provision at 52.212-3, Offeror Representations and Certifications - Commercial Items. FAR 52.212-4, Contract Terms and Conditions - Commercial Items, applies to this acquisition. The following FAR clauses in paragraph (b) of FAR clause 52.212-5, Contract Terms and Conditions Required To Implement Statutes or Executive Orders-Commercial Items, will apply: 52.222-21, 52.222-26, 52.222-35, 52.222-36, 52.222-37, 52.225-13, 52.232-34. The full text of a FAR clause may be accessed electronically at http://www.acqnet.gov/far. DFAR 252.211-7003, Item Identification and Valuation Reference: http://farsite.af.mil CCR Requirement - Company must be registered on Central Contractor Registration (CCR) before an award could be made to them. If company is not registered in CCR, they may do so by going to CCR web site at http://www.ccr.gov. Sellers must present their representations and certifications, upon request, through the Online Representations and Certifications Application (ORCA) at http:orca.bpn.gov. New equipment ONLY, NO remanufactured or used products. No "GREY" market items. Bid MUST be good for 30 calendar days after submission FOB Destination CONUS (CONtinental U.S.) Shipping charges shall be included in the purchase cost of the products. Sellers shall deliver the products on the own conveyance to the location listed on the purchase order. No partial shipments unless otherwise specified at time of order. In accordance with DFARS 252.232-7003, ?Electronic Submission of Payment Requests and Receiving Reports?, the contractor shall submit their payment request electronically using the Wide Area Workflow (WAWF). The WAWF website is located at https://wawf.eb.mil. There is no charge to use WAWF. Contractors must register to use WAWF at this website and ensure an electronic business point of contact (POC) is designated in the Central Contractor Registration site at http://www.ccr.gov within ten (10) calendar days after award of this contract. Contractor training is available at the website Home Page, under ?about WAWF?. Contractors may contact the WAWF Customer Support for assistance toll free at 866-618-5988; commercial: 801-605-7095; Fax commercial: 801-605-7453 or CSCASSIG@CSD.DISA.MIL To request a questions and answers summary please email clientservices@fedbid.com or submit a request through the "submit a question" feature. Delivery must be made within 30 days or less after receipt of order (ARO). The offeror must provide within its offer the number of days - not to exceed 30 - required to make delivery after it receives a purchase order from the buyer. The selected Offeror must comply with the following commercial item terms and conditions, which are incorporated herein by reference: FAR 52.212-1, Instructions to Offerors - Commercial Items, applies to this acquisition; FAR 52.212-3, Offeror Representations and Certifications - Commercial Items - the selected offeror must submit a completed copy of the listed representations and certifications; FAR 52.212-4, Contract Terms and Conditions - Commercial Items; FAR 52.212-5, Contract Terms and Conditions Required To Implement Statutes or Executive Orders-Commercial Items, paragraph (a) and the following clauses in paragraph (b): 52.222-21, 52.222-26, 52.222-35, 52.222-36, 52.222-37, 52.225-13, 52.232-34. The full text of the referenced FAR clauses may be accessed electronically at https://www.acquisition.gov/far/.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/641c522b744686833d9911575be7c6c4)
 
Place of Performance
Address: Fort Stewart, GA 31314
Zip Code: 31314
 
Record
SN02569547-W 20110911/110910000012-641c522b744686833d9911575be7c6c4 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.