44 -- Annual Preventative Maintenance on Boilers - Solicitation

Notice Date
8/10/2011
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
332410 — Power Boiler and Heat Exchanger Manufacturing
 
Contracting Office
Department of the Army, U. S. Army Materiel Command, Anniston Chemical Agent Disposal Facility (ANCDF), 3580 MORRISVILLE ROAD, Anniston, Alabama, 36201, United States
 
ZIP Code
36201
 
Solicitation Number
WA-FY12-AR-661
 
Archive Date
9/10/2011
 
Point of Contact
Ashley Rollins, Phone: 256-238-0721 x 131
 
E-Mail Address
ashley.rollins@wancdf.com
(ashley.rollins@wancdf.com)
 
Small Business Set-Aside
N/A
 
Description
Solicitation Subcontractor shall provide annual preventative maintenance on the following scopes: Building 695 Boilers B1 and B2 Perform checkout and calibration adjustments. •1. Check all burner linkages •2. Check low water cutoff operation •3. Check all phases of the operation of the control circuit for proper operation •4. Check operation of burner manual shutoff valves •5. Check burner flame safeguard for proper operation •6. Clean and inspect pilot assembly •7. Check air dampers for smooth operation •8. Test boiler safety valves •9. Adjust the combustion fuel / air ratio as necessary on each of the hot water boilers •10. Ensure emissions are compliant to city, state and federal regulations •11. Troubleshoot and correct any operational discrepancies found •12. Provide a written report of initial and final adjustments and any additional work performed Post Maintenance Testing (PMT) - Perform in service testing of boiler. Verify emissions are compliant to state and federal regulations PUB Boilers 201 and 202 Subcontractor to perform the following in accordance with (IAW) state and federal regulations. Perform checkout and calibration adjustments of how water boilers. •1. Adjust the combustion fuel / air ratio as necessary on each of the hot water boilers •2. Ensure emissions are compliant to city, state and federal regulations •3. Troubleshoot and correct any operational discrepancies found •4. Provide a written report of initial and final adjustments and any additional work performed Post Maintenance Testing (PMT) - Perform in service testing of boiler. Verify emissions are compliant to state and federal regulations Subcontractor(s) will participate in the pre-job briefings to ensure that good communications are established with ANCDF Subcontracts, Engineering and Maintenance departments before any work begins. Extreme caution shall be taken to ensure that unplanned outages will not occur. Subcontractor shall provide (1) copy of calibration records for any calibration equipment that is used. Subcontractor shall provide the MSDS sheet for any chemical products brought onsite. Subcontractor shall provide any special tools, test equipment and / or material.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/c0a2f18172fc07919d49545e2280439b)
 
Place of Performance
Address: Anniston, Alabama, 36202, United States
Zip Code: 36202
 
Record
SN02529125-W 20110812/110810235728-c0a2f18172fc07919d49545e2280439b (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.