Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JULY 21, 2011 FBO #3526
DOCUMENT

J -- Electrical Systems Testing/Maint - Fresno Oct 1, 2011 to Sep 30, 2012 - Attachment

Notice Date
7/19/2011
 
Notice Type
Attachment
 
NAICS
541330 — Engineering Services
 
Contracting Office
Department of Veterans Affairs;VA Sierra Pacific Network (VISN 21);VA Northern California HealthCare System;5342 Dudley Blvd. Bldg 98 (90/CCA);McClellan CA 95652-1012
 
ZIP Code
95652-1012
 
Solicitation Number
VA26111RP0676
 
Response Due
7/27/2011
 
Archive Date
10/25/2011
 
Point of Contact
Leala Jew
 
E-Mail Address
3-4516<br
 
Small Business Set-Aside
N/A
 
Description
Description The McClellan Park Consolidated Contracting Activity (CCA) is issuing a Sources Sought Notice to determine if there are any Service Disabled Veteran Owned Small Businesses (SDVOSB), Veteran Owned Small Businesses (VOSB), Women Owned Small Businesses and Small businesses that can provide all labor, materials, tools, equipment and supervision necessary to perform Electrical Systems testing and preventive maintenance upon facility electrical components per the most current addition of the National Electrical Testing Association, Maintenance Testing Specifications, for the Veterans Affairs Central California Healthcare System (VACCHS) at Fresno, California. The Contractor shall provide competent and qualified personnel and supervision during all aspects of this project. The Contractor shall be aware that due to mission requirements many aspects of the requested testing will need to be performed during the late evening and early morning hours and on weekends. Equipment to be tested includes the following: Low voltage case molded circuit breakers; Low voltage automatic circuit breakers; Low voltage switch / distribution panels; Low voltage motor control center panels; Low voltage motor control units; Medium voltage circuit breakers. All breakers 100 amps or over will be subjected to primary injection in order to test all aspects of the overload trip functions of the breaker. Equipment to be tested has varying voltages (120, 208, 277, 480, 12KV) and varying currents (5 amps to 3200 amps). The Period of Performance is for a period of one year to begin on/about Oct 1, 2011 through Sep 30, 2012. The NAICS is 541330 and the size standard is $4.5 million. Interested firms fitting one or more of the Socio-economic categories should send their information by email to leala.jew@va.gov no later than 4:00 pm Pacific Time, July 22, 2011. Information should include: Name of the Company, POC name, phone numbers, email address, CCR/DUNS number, and indicate status i.e. SDVOSD, VOSB, WOSB and/or Small Business. DISCLAIMER This sources sought notice is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to notice that is marked proprietary will be handled accordingly.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VANCHCS/VANCHCS/VA26111RP0676/listing.html)
 
Document(s)
Attachment
 
File Name: VA-261-11-RP-0676 VA-261-11-RP-0676 SOURCES SOUGHT.doc (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=220455&FileName=VA-261-11-RP-0676-000.doc)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=220455&FileName=VA-261-11-RP-0676-000.doc

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN02502773-W 20110721/110720000205-98b35ac3236185815cb89d7f884c0a9a (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.