Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JULY 10, 2011 FBO #3515
SOLICITATION NOTICE

66 -- X SERIES SIGNAL ANALYZER

Notice Date
7/8/2011
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
334515 — Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
 
Contracting Office
Department of the Air Force, Air Force Materiel Command, AFFTC - AF Flight Test Center, 5 S WOLFE AVE, Edwards AFB, California, 93524-1185, United States
 
ZIP Code
93524-1185
 
Solicitation Number
F1S0AB1144B001
 
Point of Contact
Steven A. Winner, Phone: 6612775686, MIKE KEELING, Phone: 6612772704
 
E-Mail Address
steven.winner@edwards.af.mil, mike.keeling@edwards.af.mil
(steven.winner@edwards.af.mil, mike.keeling@edwards.af.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
Combined Synopsis/Solicitation - F1S0AB1144B001 This is a combined synopsis/solicitation for commercial items prepared IAW the format in FAR Subpart 12.6 as supplemented with additional information included in this notice. This announcement constitutes the only solicitation. Quotes are being requested and an additional written solicitation will be issued. This is a Request For Quotation (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Regulation (FAR) and Supplements, Federal Acquisition Circular (FAC) 2005-53 and DFARs Change Notice (DPN) 20110629. NAICS is 334515 with a small business size standard of 500 employees. This acquisition is a 100% small business set-aside. The Air Force Flight Test Center (AFFTC), at Edwards AFB, CA is seeking potential sources capable of providing an X-Series Signal Analyzer which includes the following Specifications: BRAND NAME OR EQUAL TO: AGILENT TECHNOLOGIES X-Series Signal Analyzer REQUIREMENTS: 1. QUANTITY ONE (1) EACH, MODEL #N9000AEP-001 (Or equivalent ) AGT. CXA SIGNAL ANALYZER 2. QUANTITY ONE (1) EACH, MODEL #1CP005A AGT RACKMOUNT FLANGE & HANDLE BRAND NAME OR EQUAL TO: MODEL #N9000AEP-001 1. MODEL #N9000AEP-001 AGT. CXA SIGNAL ANALYZER 2. MODEL #1CP005A AGT RACKMOUNT FLANGE & HANDLE MINIMUM SALIENT CHARACTERISTICS/SPECIFICATIONS FOR MODEL #N9000AEP-001: • Frequency range: 9 kHz to 3.0 GHz • Frequency reference o Accuracy  [(time since last adjustment x aging rate) + temperature stability + calibration accuracy] o Aging rate : ±1 x 10-6 / year o Temperature stability: Full temperature range (±2 x 10-6 ) o Achievable initial calibration accuracy Option PFR: ±1.4 x 10-6 o Residual FM: ≤ 10 Hz p-p in 20 ms nominal • Frequency readout accuracy (start, stop, center, marker): (marker frequency x frequency reference accuracy + 0.25 % x span + 5 % x RBW + 2 Hz + 0.5 x horizontal resolution 1) • Marker frequency counter o Accuracy: (marker frequency x frequency reference accuracy + 0.100 Hz) o Delta counter accuracy: (delta frequency x frequency reference accuracy + 0.141 Hz) o Counter resolution: 0.001 Hz • Frequency span (FFT and swept mode) o Range : 0 Hz (zero span), 10 Hz to maximum frequency of instrument o Resolution: 2 Hz o Accuracy  Swept ±0.25 % x span + horizontal resolution  FFT ±0.10 % x span + horizontal resolution) • Sweep time and triggering o Range  Span = 0 Hz, 1 μs to 6000 s  Span ≥ 10 Hz, 1 ms to 4000 s o Accuracy  Span ≥ 10 Hz, swept, 0.01 % nominal  Span ≥ 10 Hz, FFT, 40 % nominal  Span = 0 Hz, 1 % nominal o Trigger  Free run, line, video, external 1, RF burst, periodic timer o Trigger delay  Span = 0 Hz or FFT, -150 to +500 ms  Span ≥ 10 Hz, swept, 1 μs to 500 ms  Resolution, 0.1 μs • Time gating o Gate methods, Gated LO; gated video; gated FFT o Gate length range (except method = FFT), 100.0 ns to 5.0 s o Gate delay range, 0 to 100.0 s o Gate delay jitter, 33.3 ns p-p nominal • Sweep (trace) point range o All spans, 1 to 40001 • Resolution bandwidth (RBW) o Range (-3.01 dB bandwidth), 1 Hz to 3 MHz (10 % steps), 4, 5, 6, 8 MHz o Bandwidth accuracy (power)  1 Hz to 750 kHz, ±1.0 % (±0.044 dB) nominal  820 kHz to 1.2 MHz (< 3 GHz CF), ± 2.0 % (± 0.088 dB) nominal  1.3 to 2.0 MHz (< 3 GHz CF), ± 0.07 dB nominal  2.2 to 3 MHz (< 3 GHz CF), ± 0.15 dB nominal  4 to 8 MHz (< 3 GHz CF),± 0.25 dB nominal o Bandwidth accuracy (-3.01 dB)  RBW range, 1 Hz to 1.3 MHz ± 2 % nominal o Selectivity (-60 dB/-3 dB), 4.1:1 nominal • Analysis bandwidth o Maximum bandwidth, 10 MHz • Video bandwidth (VBW) o Range, 1 Hz to 3 MHz (10 % steps), 4, 5, 6, 8 MHz, and wide open (labeled 50 MHz) o Accuracy,± 6 % nominal • Measurement speed o Local measurement and display update rate, 11 ms (90/s) nominal o Remote measurement and LAN transfer rate, 6 ms (167/s) nominal o Marker peak search, 5 ms nominal o Center frequency tune and transfer (RF), 22 ms nominal o Measurement/mode switching, 75 ms nominal • Amplitude range o Measurement range  Preamp off • 100 kHz - 1 MHz, Displayed average noise level (DANL) to +20 dBm • 1 MHz - 7.5 GHz, Displayed average noise level (DANL) to +23 dBm  Preamp on • 100 kHz - 7.5 GHz Displayed average noise level (DANL) to +15 dBm o Input attenuator range  (100 kHz to 7.5 GHz), 0 to 50 dB in 10 dB steps • Maximum safe input level o Average total power  +30 dBm (1 W), Input attenuation ≥ 20 dB, preamp off  +10 dBm (10 mW) Input attenuation ≥ 20 dB, preamp on o Peak pulse power  +50 dBm (100 W) < 10 μs pulse width, < 1 % duty cycle, input attenuation ≥ 30 dB o AC coupled, ± 50 Vdc • Display range o Log scale  0.1 to 1 dB/division in 0.1 dB steps  1 to 20 dB/division in 1 dB steps (10 display divisions) o Linear scale, 10 divisions o Scale units, o dBm, dBmV, dBμV, dBmA, dBμA, V, W, A \ • Frequency response o (10 dB input attenuation, 20 to 30 °C, σ = nominal standard deviation) Specification 95th percentile (≈ 2σ) Preamp off 9 kHz to 10 MHz ± 0.60 d ± 0.45 dB 10 MHz to 3 GHz ± 0.75 dB ± 0.55 dB 3 to 5.25 GHz ± 1.45 dB ± 1.00 dB 5.25 to 7.5 GHz ± 1.65 dB ± 1.20 dB • Input attenuation switching uncertainty Specifications Additional information Attenuation > 2 dB, preamp off Relative to 10 dB (reference setting) 50 MHz (reference frequency) ± 0.32 dB ± 015 dB typical 100 kHz to 3.0 GHz ± 0.30 dB nominal 3.0 to 7.5 GHz ± 0.50 dB nominal • Total absolute amplitude accuracy o (10 dB attenuation, 20 to 30 °C, 1 Hz ≤ RBW ≤ 1 MHz, input signal -10 to -50 dBm, all settings auto-coupled except Auto Swp Time = Accy, any reference level, any scale, σ = nominal standard deviation)  At 50 MHz± 0.40 dB  At all frequencies± (0.40 dB + frequency response)  100 kHz to 10 MHz± 0.40 dB (95th Percentile ≈ 2σ)  10 MHz to 2.0 GHz± 0.50 dB (95th Percentile ≈ 2σ)  2.0 to 3.0 GHz± 0.60 dB (95th Percentile ≈ 2σ) • Input voltage standing wave ratio (VSWR) o Preamp off (10 dB attenuation)  300 MHz to 1 GHz< 1.2:1 nominal  1 to 3 GHz< 1.5:1 nominal  3 to 7.5 GHz< 2.0:1 nominal o Preamp on (0 dB attenuation)  10 MHz to 3 GHz< 2.2:1 nominal  3 to 7.5 GHz< 2.4:1 nominal • Resolution bandwidth switching uncertainty (referenced to 30 kHz RBW) o 1 Hz to 3 MHz RBW, ± 0.15 dB o 4, 5, 6, 8 MHz RBW, ± 1.0 dB • Reference level o Range  Log scale, -170 to +23 dBm in 0.01 dB steps  Linear scale, Same as log (707 pV to 3.16 V) o Accuracy, 0 dB • Display scale switching uncertainty o Switching between linear and log, 0 dB o Log scale/div switching, 0 dB • Display scale fidelity o -80 dBm ≤ input mixer level < -15 dBm, ± 0.15 dB total o -15 dBm ≤ input mixer level < -10 dBm, ± 0.30 dB, ± 0.15 dB typical • Trace detectors o Normal, peak, sample, negative peak, log power average, RMS average, and voltage average • Dynamic Range Specifications o 1 dB gain compression (two-tone), Total power at input mixer o Preamp off 50 MHz to 7.5 GHz, +2 dBm nominal • Displayed average noise level (DANL) o (Input terminated, sample or average detector, averaging type = Log, 0 dB input attenuation, IF Gain = High, 20 to 30 °C) Specification Typical 9 kHz to 1 MHz -120 dBm 1 to 10 MHz -130 dBm -137 dBm 10 MHz to 1.5 GHz -148 dBm -150 dBm 1.5 to 2.2 GHz -144 dBm -147 dBm 2.2 to 3 GHz -140 dBm -143 dBm 3 to 4.5 GHz -137 dBm -140 dBm 4.5 to 6 GHz -133 dBm -136 dBm 6 to 7.5 GHz -128 dBm -131 dBm • Spurious responses o Residual responses(Input terminated and 0 dB attenuation, 20 to 30 °C)  200 kHz to 7.5 GHz (swept), -90 dBm  Zero span or FFT or other frequencies, -100 dBm nominal o LO related spurious  10 MHz to 7.5 GHz -60 dBc typical o System related sidebands  Offset from CW signal  50 to 200 Hz, -60 dBc nominal  200 Hz to 300 kHz, -65 dBc nominal  300 kHz to 10 MHz, -80 dBc nominal • Second harmonic distortion (SHI) o (Input level -20 dBm, input attenuation 10 dB)  Source frequency 10 MHz to 3.75 GHz  SHI +35 dBm  SHI (nominal) +42 dBm • Third-order intermodulation distortion (TOI) (Two -20 dBm tones at input mixer spaced by 100 kHz, 0 dB attenuation, 20 to 30 °C) Distortion TOI TOI (typical) 10 to 400 MHz -60 dBc +10 dBm +14 dBm 400 MHz to 3 GHz -66 dBc +13 dBm +17 dBm 3 to 7.5 GHz -66 dBc +13 dBm +15 dBm • Phase noise Offset Specification Typical Noise sidebands (20 to 30 °C, CF = 1 GHz) 1 kHz -94 dBc/Hz -98 dBc/Hz nominal 10 kHz -99 dBc/Hz -102 dBc/Hz 100 kHz -102 dBc/Hz -104 dBc/Hz 1 MHz -120 dBc/Hz -121 dBc/Hz 10 MHz -143 dBc/Hz nominal • PowerSuite Measurement Specifications • Channel power o Amplitude accuracy, W-CDMA or IS95 (20 to 30 °C, attenuation = 10 dB)  ± 1.15 dB (± 0.60 dB 95th percentile) • Occupied bandwidth o Frequency accuracy, ± [span/1000] nominal • Adjacent channel power o Accuracy, W-CDMA (ACLR)(at specific mixer levels and ACLR ranges)  MS, adjacent ± 0.41 dB, alternate ± 0.55 dB  BTS, adjacent ± 1.92 dB, alternate ± 1.22 dB o Dynamic range (typical)  Without noise correction, adjacent -63 dB, alternate -67 dB  With noise correction, adjacent -66 dB, alternate -72 dB o Offset channel pairs measured, 1 to 6 o Multiple number of carriers measured, Up to 12 • Power statistics CCDF o Histogram resolution, 0.01 dB • Harmonic distortion o Maximum harmonic number, 10th o Result, Fundamental power (dBm), relative harmonics power (dBc), total harmonic distortion in % • Intermod (TOI) o Measure the third-order products and intercepts from two tones • Burst power o Methods, Power above threshold, power within burst width o Results, Single burst output power, average output power, maximum power, minimum power within burst, burst width • Spurious emission o W-CDMA (1 to 3.0 GHz) table-driven spurious signals; search across regions o Dynamic range, 86.6 dB, (91.6 dB typical) o Absolute sensitivity, -75.4 dBm, (-80.4 dBm typical) • Spectrum emission mask (SEM) o cdma2000R (750 kHz offset)  Relative dynamic range (30 kHz RBW), 71.5 dB, (79.1 dB typical)  Absolute sensitivity, -90.7 dBm, (-95.7 dBm typical)  Relative accuracy, ± 0.11 dB o 3GPP W-CDMA (2.515 MHz offset)  Relative dynamic range (30 kHz RBW), 70.5 dB, (74.7 dB typical)  Absolute sensitivity, -90.7 dBm, (-95.7 dBm typical)  Relative accuracy, ± 0.11 dB • General Specifications • Temperature range o Operating, 5 to 50 °C o Storage, -40 to 65 °C • EMC • Complies with European EMC Directive 2004/108/EC o IEC/EN 61326-1 or IEC/EN 61326-2-1 o CISPR Pub 11 Group 1, class A o AS/NZS CISPR 11:2002 o ICES/NMB-001 • Safety o Complies with European Low Voltage Directive 73/23/EEC, amended by 93/68/EEC o IEC/EN 61010-1 2nd Edition o Canada: CSA C22.2 No. 61010-1 o USA: UL 61010-1 2nd Edition • Power requirements o Voltage and frequency (nominal)  100 to 120 V, 50/60/400  Hz220 to 240 V, 50/60 Hz o Power consumption  On, 270 W maximum  Standby, 20 W • Dimensions o 19 inch rack mount compatible • Inputs and Outputs o RF input  Connector Type-N female, 50 Ω nominal o Ext Ref In  Connector, BNC female, 50 Ω nominal  Input amplitude range, -5 to 10 dBm nominal  Input frequency, 10 MHz ± nominal  Frequency lock range, ± 5 x 10-6 of specified external reference input frequency Delivery: 90 DARO or Less Place of delivery, performance, and acceptance is FOB Destination, Edwards AFB, CA 93524. Interested parties who believe they can meet all the requirements for the items described in this synopsis are invited to submit in writing a complete quote including delivery FOB destination Edwards AFB, CA 93524. Offerors are required to submit with their quote enough information for the Government to evaluate the minimum requirements detailed in this synopsis. CONTRACTORS MUST COMPLY WITH FAR 52.204-7 CENTRAL CONTRACTOR REGISTRATION AND DFARS 252.204-7004, ALTERNATE A. INTERESTED CONTRACTORS CAN ACCESS THE CLAUSES BY INTERNET URL: http://farsite.hill.af.mil. TO REGISTER WITH THE CCR, GO TO URL: http://www.ccr.gov/. ONLINE REPRESENTATIONS AND CERTIFICATIONS APPLICATION (ORCA) MUST BE COMPLETED. USE OF ONLINE REPRESENTATIONS AND CERTIFICATIONS APPLICATION (ORCA) BECAME MANDATORY 1 JANUARY 2005. CONTRACTORS CAN ACCESS ORCA THROUGH CCR BY INTERNET URL: http://www.ccr.gov/. The following provisions and clauses apply: Clause 52.211-6 Brand Name or Equal; Provision 52.212-1, Instructions to Offerors--Commercial; Clause 52.212-2 Evaluation-Commercial Items; the following factor shall be used to evaluate offers: Lowest price technically acceptable offer, Technically acceptable is meeting all minimum salient characteristics; clause 52.212-4, Contract Terms and Conditions--Commercial Items; clause 52.212-5, Contract Terms and Conditions Required to Implement Statutes Or Executive Orders--Commercial Items (to include: 52.222-26, Equal Opportunity; 52.222-35, Affirmative Action for Special Disabled and Vietnam Era Veterans; 52.222-36, Affirmative Action for Handicapped Workers; 52.222-37, Employment Reports on Special Disabled Veterans and Veterans of the Vietnam Era); Clause 52.232-33 Mandatory information for electronic funds transfer payment. The following DFARs clauses apply to this acquisition: Clause 252.212-7001, Contract Terms and Conditions Required to Implement Statutes or Executive Orders Applicable to Defense Acquisition of Commercial Items; 252.225-7001 Buy American Act and Balance of Payment Program: The following AFFARS clauses apply to this acquisition: Clause 5352.223-9000, Elimination of Use of Class I Ozone Depleting Materials, 252.211-7003, Item Identification and valuation; 252.232-7010. Levies on Contract Payments; 5352.201-910, Ombudsman; 5352.242-9000, Offers are due at the Air Force Flight Test Center, Directorate of Contracting, 5 South Wolfe Avenue, Building 2800, Edwards AFB, CA, 93524, not later than July 18, 2011 at 3:30 pm PST. E-mail address: steven.winner@edwards.af.mil. Phone: 661-277-5686 Fax: 661-277-0470
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFMC/AFFTC/F1S0AB1144B001/listing.html)
 
Place of Performance
Address: AFFTC/PKEE, 5 South Wolfe Avenue, Bldg. 2800, Edwards Air Force Base, California, 93524, United States
Zip Code: 93524
 
Record
SN02493900-W 20110710/110708235315-a231c18df455920ed19eb3f44c41d00f (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.