Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MARCH 12, 2011 FBO #3395
SOLICITATION NOTICE

J -- FY 11 Dry Dock of CGC Scioto

Notice Date
3/10/2011
 
Notice Type
Presolicitation
 
NAICS
333611 — Turbine and Turbine Generator Set Units Manufacturing
 
Contracting Office
Department of Homeland Security, United States Coast Guard (USCG), USCG Surface Forces Logistics Center (SFLC), 2401 Hawkins Point Road, Building 31, Mail Stop 26, Baltimore, Maryland, 21226-5000, United States
 
ZIP Code
21226-5000
 
Solicitation Number
HSCG85-11-Q-P45M43A
 
Point of Contact
Kathy J. Fields, Phone: 410-762-6473
 
E-Mail Address
kathy.j.fields@uscg.mil
(kathy.j.fields@uscg.mil)
 
Small Business Set-Aside
N/A
 
Description
The United States Coast Guard Surface Forces Logistics Center, Contracting and Procurement Branch 2, intends to issue a Commercial Request for Quote (RFQ) for Dry Dock Repairs to the USCGC SCIOTO (WLR-65504), a 65' Foot "B" Class River Buoy Tender, USCG 100 Barge (99002). The Coast Guard intends to conduct the procurement in accordance with Federal Acquisition Regulation (FAR) Part 12, Acquisition of Commercial Items, and FAR Subpart 13.5, Test Program for Certain Commercial Items. The NAICS Code is 336611 and the small business size standard is less than 1,000 employees. The acquisition will be issued as a Best Value Request for Quote (RFQ), on or about March 25, 2011. The RFQ will be issued via the Federal Business Opportunity (FEDBIZOPPS) web page at www.fbo.gov. This requirement will be evaluated using past performance as an evaluation factor. Hard copies of the specification and solicitation will not be issued. It is incumbent upon contractors to monitor the FEDBIZOPPS web page for RFQ release and all subsequent amendments. FEDBIZOPPS also contains an optional automatic notification service. A CD-ROM containing all applicable drawings is available free of charge to contractors upon request not later than three (3) days from the solicitation issuance. The CD-ROM(s) contain WINDOWS compliant raster/vector formats (e.g.*.DWF, etc). The acquisition is for DRYDOCK repairs to the USCGC SCIOTO (WLR 65504) 65 Foot "B" Class River Buoy Tender, USCG 100 Barge (99002) home ported in Keokuk, IA. The performance period will be 90 calendar days with a start date on or about June 12, 2011. The place of performance will be at the contractor's facility. The geographical restriction is restricted to the Western Rivers of the United States. The "Western Rivers" means the navigable portions of the Mississippi River and its tributaries above mile marker 0 of the Lower Mississippi River. Navigable tributaries of the Mississippi River include only the waterways within the area of jurisdiction of Coast Guard aids to navigation facilities as described in Light List Volume V (COMDTINST M16502.5), and the Tennessee-Tombigbee Waterway to the mouth of the Mobile River. This includes protected portions of the Intra Coastal Waterway connected to the "Western Rivers," but specially excludes unprotected or open waters such as Mobile Bay, Lake Borgne, and the Gulf of Mexico. The dry-dock facility and its approaches shall have a minimum water depth of 8 feet and, a minimum vertical clearance of 45 feet. The scope of the acquisition is for the overhauling, renewing, and repairing various items aboard the USCGC SCIOTO (WLR-65504). This work will include, but is not limited to perform Hull Plating, U/W Body, Inspect, Tender & Barge, Hull Plating U/W Body, Ultrasound Testing - Tender & Barge, Hull and Structural Plating - 3/16" Steel Plate, Repair, Hull & Structural Plating - Degraded Weld (Steel), Repair, Appendages (U/W), Leak Test - Tender, Appendages (U/W), Internal Preserve, Tender, Tanks (MP Fuel Service), Clean - Tender, Spuds, Overhaul - Tender, Spuds, Overhaul - Barge, Spud Wells, Preserve - Tender, Spud Wells, Preserve- Barge, Tanks (Potable Water), Preserve "100%" - Tender, Tanks (Potable Water), Preserve "100%"- Barge, Decks, Exterior (Barge Buoy), Preserve, Decks - Exterior, Preserve ("Non-Skid Broadcast Grit" System) - Tender, Decks - Exterior, Preserve ("non-Skid Broadcast Grit" System) - Barge, U/W Body, Preserve (100%) - Tender, U/W Body, Preserve ("100%") - Barge, U/W Body, Preserve ("Partial - Condition A") - Tender, U/W Body, Preserve ("Partial - Condition A") - Barge, U/W Body, Preserve ("Partial - Condition B") - Tender, U/W Body, Preserve ("Partial - Condition B") - Barge, Dry-docking - Tender & Barge, Temporary Services, Boat Davit Winch, Shrink Wrap, Buoy and Cargo Handling Crane, Shrink Wrap, Keel Coolers - Barge, Clean, Inspect & Hydro, Main Diesel Engine & Propulsion shafting, upgrade, Steering Systems, Upgrade, Bilge, Prepare - Barge, Sea Strainers, Overhaul, Composite Labor Rate, GFP Report, and Laydays. All welding and brazing shall be accomplished by trained welders, who have been certified by the applicable regulatory code performance qualification procedures. All responsible sources may submit an offer which will be considered by the government. For further information or questions regarding this solicitation or a copy of the CD -ROM, please contact Kathy J. Fields at (410) 762-6473, or by e-mail to Kathy.J.Fields@uscg.mil.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DHS/USCG/USCGELC/HSCG85-11-Q-P45M43A/listing.html)
 
Place of Performance
Address: At Contractor's Facility, United States
 
Record
SN02398403-W 20110312/110310234928-a27a9b87ed7d1f608ba28eefea1b35a4 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.