Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF FEBRUARY 25, 2011 FBO #3380
SOURCES SOUGHT

L -- Top End Overhaul of #1 Ships Service Diesel Generator Prime Mover

Notice Date
2/23/2011
 
Notice Type
Sources Sought
 
NAICS
336611 — Ship Building and Repairing
 
Contracting Office
Department of Homeland Security, United States Coast Guard (USCG), USCG Surface Forces Logistics Center (SFLC) Procurement Branch 2, 1301 Clay St., Suite 807N, Oakland, California, 94612-5249, United States
 
ZIP Code
94612-5249
 
Solicitation Number
USCGC_CYPRESS_ENGINE_OVERHAUL
 
Archive Date
3/17/2011
 
Point of Contact
Jack Rodman, Phone: (510) 637-5988, Linda C Cho, Phone: 510-637-5965
 
E-Mail Address
Jack.E.Rodman@uscg.mil, linda.c.cho@uscg.mil
(Jack.E.Rodman@uscg.mil, linda.c.cho@uscg.mil)
 
Small Business Set-Aside
N/A
 
Description
The U. S. Coast Guard is considering whether or not to set-aside an acquisition for HUBZone concerns, Service-Disabled Veteran-owned Small Business concerns (SDVOSB), or for Small Businesses. This is not a solicitation or offer. No contract or order will result from this announcement. Response by interested parties must be made by 12:00 pm PST on March 2, 2011. The NAICS Code is 336611. The small business size standard is less than 1000 employees. The acquisition is for Technical Representative Support Services for Dockside overhaul/repairs to the USCGC CYPRESS (WLB-210) the before mention Cutter is a 225 Foot Sea Going Buoy Tender. The homeport of the vessel is Naval Air Station Pensacola, Florida. The performance period is expected to begin on or about May 16, 2011 and be completed within 13 days. The acquisition for the contractor to provide all parts, special tools and labor to complete an Initial Top End Overhaul of the #1 Ships Service Diesel Generator Prime Mover, Caterpillar Series 3508 Engine. To include but not limited to: Overhaul or renewal of all attached pumps, and cleaning of all coolers. Work is to be conducted in frame. Technical representatives will verify with ships force prior to and following completion of overhaul the proper operation of the engine. Technical representative(s) must be certified by Caterpillar. All work will be performed on board the Cutter at its respective home port. Composite Labor Rate, GFE Report, and Travel and Per Diem All welding and brazing shall be accomplished by trained welders who have been certified by the applicable regulatory code performance qualification procedures. In accordance with FAR 19.1305, if your firm is HUB Zone certified or a Service-Disabled Veteran-Owned Small Business and intends to submit an offer on this acquisition, please respond by email to Jack.E.Rodman@uscg.mil and include: (a) a positive statement of your intention to submit a bid for this solicitation as a prime contractor; (b) evidence of experience in work similar in type and scope to include contract numbers, project titles, dollar amounts, points of contact and telephone numbers; (c) past performance references with points of contact and telephone numbers. At least two references are requested, but more are desirable. Your response is required by 2 March 2011 at 12:00 pm PST. Contractors are reminded that should this acquisition become a HUB Zone set-aside, FAR 52.219-3, Notice of Total HUB Zone Set-Aside will apply which requires that at least 50 percent of the cost of personnel for contract performance be spent for employees of the concern. Contractors are also reminded that should this acquisition become a Service-Disabled Veteran-Owned Small Business Set-Aside, FAR 52.219-27, Notice of Total Service-Disabled Veteran-Owned Small Business Set-Aside will apply which requires that at least 50 percent of the cost of personnel for contract performance be spent for employees of the concern. All of the above information must be submitted in sufficient detail for a decision to be made on a HUB Zone, Service disabled Veteran-Owned Small Business Set-Aside or Small Business Set-Aside. Failure to submit all information requested may result in an unrestricted acquisition. A decision on whether this will be pursued as a HUB Zone or SDVOSB Set-Aside, or Small Business Set-Aside will be posted in the FedBizOpps website at http://www.fedbizopps.gov. Please submit your questions via email to Jack E. Rodman, Contract Specialist at Jack.E.Rodman@uscg.mil.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DHS/USCG/VPLMLCP/USCGC_CYPRESS_ENGINE_OVERHAUL/listing.html)
 
Place of Performance
Address: Naval Air Station Pensacola, 211 South Ave Bldg, Pensocola, Florida, 32508, United States
Zip Code: 32508
 
Record
SN02385771-W 20110225/110223234440-837c4e303b3ef6861998f70a97f30773 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.