Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF DECEMBER 30, 2010 FBO #3323
MODIFICATION

J -- F2F3230299AU02 - Repair Well Pump

Notice Date
12/28/2010
 
Notice Type
Modification/Amendment
 
NAICS
237110 — Water and Sewer Line and Related Structures Construction
 
Contracting Office
Department of the Air Force, Air Force Special Operations Command, 1 SOCONS- Hurlburt, 350 Tully Street, Hurlburt Field, Florida, 32544-5810, United States
 
ZIP Code
32544-5810
 
Solicitation Number
F2F3230299AU02
 
Archive Date
1/19/2011
 
Point of Contact
Timothy M Thulin, Phone: 850-884-3137, Leigh Ann Gunter, Phone: 850-884-1269
 
E-Mail Address
timothy.thulin@hurlburt.af.mil, leigh.gunter@hurlburt.af.mil
(timothy.thulin@hurlburt.af.mil, leigh.gunter@hurlburt.af.mil)
 
Small Business Set-Aside
HUBZone
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. Solicitation Number F2F3230299AU02 is hereby issued as a Request for Proposal. This combined synopsis/solicitation and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) Fac 2005-46, Effective 29 Oct 2010. This acquisition is set aside for HUBZone Procurement Program concerns. The North American Industry Classification System (NAICS) code for this project is 237110, and Standard Industrial Classification (SIC) code 1781. The Size Standard for NAICS 237110 is $33.5M. Pricing should be broken out as follows: 0001: Pull 200' of column pipe and bowl assembly, tear down and inspect pump. 0002: Replace out of tolerence complete section of column pipe to include line shaft and bearings. 0003: Rebuild 5 stage 10" floway pump bowl: to include shaft bushings, wear rings sand blast and epoxy coating. 0004: Rebuild packing box and sand blast and paint discharge head. 0005: Reinstall pump, 200' of column pipe, 200' 1/4" air line and discharge head. Level discharge head, and make all mechanical and electrical connections to discharge piping. The contractor shall provide all labor, equipment, materials, tools, parts, shipping, and all other items necessary to provide the following items: Remove, repair and replace existing well pump. See attached Statement of Work for description of the requirement. Delivery Terms are FOB Destination for delivery to 1 SOCES/CEOIU, Hurlburt Field, FL.. The following provisions and clauses apply to this solicitation and will remain in full force in any resultant award: FAR 52.212-1, Instructions to Offerors - Commercial Items (June 2008). It is amended to read: Offeror shall submit signed and dated offer to 1 SOCONS/LGCA, Attn: SrA Brien Burner, 350 Tully Street, Building 90339, Hurlburt Field FL 32544-5810, by 4 January 2010 1:00 p.m. CST. A Site Visit is scheduled for Tuesday, 14 December 2010 at 1400 central time. The purpose of this visit is to view the facility and current equipment. Please notify SrA Brien Burner not later than 9:00 a.m. on Monday, 13 December 2010 by e-mail brien.burner@hurlburt.af.mil or fax to SrA Brien Burner at 850-884-2041 your intent to attend the site visit including names of all attendees and their social security number or driver's license number with state of issue. In order to drive on Hurlburt Field you must bring the following: valid automobile registration, proof of automobile insurance, and a valid driver's license. As a reminder Submit signed and dated Offer Schedule marked with solicitation number F2F3230299AU02. The government reserves the right to evaluate proposals and award a contract without discussions with offerors. Offers shall be evaluated in accordance with FAR 52.212-2, Evaluation of Commercial Items (Jan 1999) which is incorporated into this Request for Proposal, with an addendum to paragraph (a) as follows: The following factors shall be used to evaluate offers: (i) Technical capability (ii) Price. Technical capability is approximately equal to price. FAR 52.212-4 Contract Terms and Conditions -- Commercial Items (Jun 2010) and FAR 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders - Commercial Items (Jun 2010) (Deviation) also apply to this Request for Proposal. FAR 52.212-3, Offeror Representations and Certifications (Aug 2009) - Commercial Items applies to this Request for Proposal and the offeror must include a completed copy of this provision with their proposal or indicate (with DUNS Number) that current information is available on the federal government website ORCA (https://orca.bpn.gov/). The full text of these clauses and provisions may be assessed electronically at the website: http://farsite.hill.af.mil. Prospective contractors must be registered in the Central Contractor Registration Database prior to award of a government contract. Additionally, the offeror shall comply with the DFARS clause at 252.223-7003 Electronic Submission of Payment Requests and Receiving Reports (Mar 2008) Point of contact is SSgt Timothy Thulin, Contract Specialist, Phone (850) 884-3137, email: timothy.thulin@hurlburt.af.mil ; Leigh Ann Gunter, Contracting Officer, (850) 884-1269, email: leigh.gunter@hurlburt.af.mil. List of Attachments: a. Statement of Work
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFSOC/16CS/F2F3230299AU02/listing.html)
 
Place of Performance
Address: BLDG 91136, Hurlburt Field, Florida, 32566, United States
Zip Code: 32566
 
Record
SN02351539-W 20101230/101228233939-67062b13a9a79652b23b055b3ff84ca2 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.