Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF AUGUST 22, 2010 FBO #3193
SOLICITATION NOTICE

66 -- RECOVERY – Acquisition of a Multisizer – RFQ499001

Notice Date
8/20/2010
 
Notice Type
Presolicitation
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
Department of Health and Human Services, National Institutes of Health, National Institute of Allergy & Infectious Diseases/AMOB, 10401 Fernwood Drive, Suite 2NE70, MSC 4811, Bethesda, Maryland, 20817
 
ZIP Code
20817
 
Solicitation Number
RFQ499001
 
Archive Date
9/15/2010
 
Point of Contact
Reyes Rodriguez, Phone: 301-402-6074, Linda C Taylor, Phone: 301-402-5762
 
E-Mail Address
rodriguezra@niaid.nih.gov, ltaylor@niaid.nih.gov
(rodriguezra@niaid.nih.gov, ltaylor@niaid.nih.gov)
 
Small Business Set-Aside
N/A
 
Description
The National Institute of Health in Bethesda, MD intends to procure a Multisizer with the following specifications: Overall Particle Size Range: 0.4 µm to 1600 µm in diameter; 0.033 fL to 2.145 x 109 fL or µm3 in volume; Aperture Diameter: 20 µm to 2000 µm apertures; Aperture Dynamic Range: Standard 1:30 (by diameter); Total 1:40 (by diameter); Standard 1:27,000 (by volume); Total 1:64,000 (by volume); Aperture Range: Total range: 2% to 80% of aperture diameter. Standard Range: 2% to 60% of aperture diameter. Extended Range: 60% to 80% of aperture diameter; Resolution: User selectable; Number of Channels: Pulse data is digitized and can be processed to achieve up to 400 size channels for a selected pulse range. Number of channels and range can be reprocessed as necessary; Electrolyte Solutions: All aqueous and non-aqueous electrolyte solution; Digital Pulse Processor: High-speed digitalization of the signal; Pulse Data: Time stamped pulses up to 525,000 per single analysis; Size Distribution Data: Size distribution by diameter, volume and area for number, number%, number/ml, volume, volume%, volume/ml, surface area, surface area% and surface area/ml; Pulse Distribution Data: Pulse distribution by time, sequence and width for pulse height diameter, pulse height volume, pulse height volt, pulse width, pulse area, average pulse height diameter, average pulse height volume and average pulse width. Number distribution by width; Linearity: ± 1% for diameter ± 3% for volume; Aperture Current Range: 30 µA - 6000 µA in 0.2 µA steps; Aperture Current Accuracy: ± 0.4% of setting; Polarity Error: Less than 0.5%; Time Mode: 0.1 to 999 seconds, selectable in 10 ms increments. Typically, time analysis is 10 to 90 seconds; Total Count Mode: 50 to 500,000 counts; Modal Count Mode: 10 to 100,000 counts; Volumetric Mode: Continuously selectable from 50 µl to 2000 µl; Metering System: Mercury-free, wide range metering pump; Volumetric Pump Accuracy: Better than 99.5%; Regulatory Compliance: The software enables 21 CFR Part 11 compliance. This procurement will be firm-fixed price and will be competed under pre-existing Multiple Award Federal Supply Schedule contracts. A competitive solicitation (RFQ) will be issued via GSA eBuy. This will be funded in whole by the American Recovery and Reinvestment Act of 2009.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/HHS/NIH/AMOB/RFQ499001/listing.html)
 
Place of Performance
Address: National Institutes of Health, NIAID, 9000 Rockville Pike, Bethesda, Maryland, 20892, United States
Zip Code: 20892
 
Record
SN02248555-W 20100822/100820234933-c52255c86351cd82a348beaf331deaa9 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.