FBO DAILY ISSUE OF AUGUST 01, 2010 FBO #3172
MODIFICATION

66 -- Transducer Calibration and Wide-Band Dynamic Signal Analysis System (TCDSAS)

Notice Date
7/30/2010
 
Notice Type
Modification/Amendment
 
NAICS
333314 — Optical Instrument and Lens Manufacturing
 
Contracting Office
Department of Commerce, National Institute of Standards and Technology (NIST), Acquisition Management Division, 100 Bureau Drive, Building 301, Room B129, Mail Stop 1640, Gaithersburg, Maryland, 20899-1640
 
ZIP Code
20899-1640
 
Solicitation Number
SB1341-10-RQ-0545
 
Archive Date
9/30/2010
 
Point of Contact
Joni L Laster, Phone: 301-975-8397, Todd D Hill, Phone: 301-975-8802
 
E-Mail Address
joni.laster@nist.gov, todd.hill@nist.gov
(joni.laster@nist.gov, todd.hill@nist.gov)
 
Small Business Set-Aside
N/A
 
Description
The purpose of this amendment is to address the following vendor questions/answers : Question: Based on the previous questions/answers provided, it is now understood that NIST intends to integrate the proposed system with their existing shaker, amplifier and reference transducers. In order to insure that quoter's are able to interface with the existing components, please provide the model numbers of the shaker, amplifier and reference sensors (if specifications for these components are not publically available online, also provide the specification sheet). In the case that these are components manufactured by NIST, please provide the pertinent technical specification and interface details. Answer: The power amplifier is a Crown DC300A Series II; the reference transducers are either a Kistler model 8002K or model 808K1; and the vibration generators are Dimoff electrodynamic vibration generators which were designed and have been maintained by NIST. The nominal maximum amplitude limits of the Dimoff vibration generators as a function of frequency are: 10 Hz - 2 gn; 15 Hz - 5 gn; and 30 Hz to 10 kHz - 10 gn. The input to the power amplifier is connected to the output of the function generator of the DSA; the output of the power amplifier is selectively connected manually to the drive coil of one of two Dimoff vibration generators; and the output of the associated reference transducer is connected to one of two inputs of the DSA. The software shall automatically select the appropriate drive voltage to the power amplifier as a function of frequency based on the measured output of the reference transducer and its calibrated sensitivity at select sinusoidal frequencies and amplitudes defined by the user - see specifications 4, Item 12, Item 13 and Item 24. The time frame for submitting questions has ended. The due date for quotes, August 5, 2010 at 3pm remains unchanged and only quotations received by the due date/time shall be considered.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOC/NIST/AcAsD/SB1341-10-RQ-0545/listing.html)
 
Place of Performance
Address: 100 Bureau Drive, Gaithersburg, Maryland, 20899, United States
Zip Code: 20899
 
Record
SN02224694-W 20100801/100730235800-17d49d5980132a22bd4262bb36384975 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.