Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF AUGUST 01, 2010 FBO #3172
AWARD

Z -- RECOVERY--Z--PROJECT NUMBER 5790, Fall River Lake, KS

Notice Date
7/30/2010
 
Notice Type
Award Notice
 
NAICS
237990 — Other Heavy and Civil Engineering Construction
 
Contracting Office
USACE District, Tulsa, ATTN: CESWT-CT, 1645 South 101st East Avenue, Tulsa, OK 74128-4609
 
ZIP Code
74128-4609
 
Solicitation Number
W912BV-09-R-1010
 
Archive Date
8/29/2010
 
Point of Contact
Phyllis O. Jordan, 918 832-4120
 
E-Mail Address
USACE District, Tulsa
(phyllis.jordan@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Award Number
W912BV-09-D-1010, TO #0001, 000102
 
Award Date
7/30/2010
 
Awardee
HARTMAN-WALSH CORPORATION (008908568)<br> 7144 N MARKET ST<br> SAINT LOUIS, MO 63133-1899
 
Award Amount
$7,800.00
 
Line Number
1
 
Description
RECOVERY - PER FAR 5.7 THIS NOTICE IS PROVIDED FOR INFORMATION PURPOSES ONLY; THEREFORE FAR 5.203 DOES NOT APPLY. THIS OPPORTUNITY WAS AVAILABLE ONLY TO CONTRACTOR(S) UNDER: MATOC As part of Operations and Maintenance, Army, Recovery Act, this modification has been issued to Hartman Walsh Painting Company, to perform the following work: 1.1 Provide labor, materials and equipment to repair the cracked weld identified on the vertical strut and skin plate on tainter gate #2. Work includes: removing the existing paint around the cracked weld, grind/remove the full length (plus 1-inch) and depth of the cracked weld down to original steel, reweld the strut and skin plate connection with a 1/4-inch fillet weld. In the event that a gap is present insert a shim between the strut and skin plate and use either a larger fillet weld or step down with 2 fillet welds. 1.2 All steel repairs shall follow specification 05 05 50 of the original conract. All welds, procedures, qualifications, personnel etc., shall conform to the original construction specifications section 05 05 50 and as directed by the USACE Tulsa District EC-DC office. A certified welder/fabrication shop shall perform all welding and a certified welding inspector (C.W.I.) shall inspect all repair work; refer to specification 05055. All replaced steel components shall be properly prepared and painted per specification 099702 section 3.1.2. Paint system shall be system 5-E-Z. 1.3 Upon completion of the weld repairs the contractor shall prep and paint the heat damaged gate surfaces with the 5-E-Z paint system, on both the upstream and downstream sections of the tainter gate.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA56/W912BV-09-R-1010/listing.html)
 
Record
SN02223661-W 20100801/100730234844-29162b26615c1726b8c909f6f19c493f (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers