Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JULY 29, 2010 FBO #3169
SOLICITATION NOTICE

25 -- Hard shell Cargo Bed Covers

Notice Date
7/27/2010
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
325211 — Plastics Material and Resin Manufacturing
 
Contracting Office
Department of the Army, National Guard Bureau, USPFO for North Carolina, 4201 Reedy Creek Road, Raleigh, North Carolina, 27607-6412
 
ZIP Code
27607-6412
 
Solicitation Number
W36M6701731025
 
Archive Date
8/21/2010
 
Point of Contact
Derek Meilinger, Phone: 2106435790
 
E-Mail Address
derek.meilinger@us.army.mil
(derek.meilinger@us.army.mil)
 
Small Business Set-Aside
N/A
 
Description
Requesting quotes for 30 M1165 Hard Shell Cargo Bed covers finished in OD Green CARC paint and woodland camo. Also, 25 M1152 Hard Shell Covers finished in OD Green CARC paint and woodland camo. Include all shipping charges with the quotation. Included below are the specification for the cargo bed covers. M1165 Cargo Bed Cover Specifications 1) Shelter - Vacuum Assist Resin Transfer Molded,.500 inch thickness in roof section. Engineered 3D fabric. High insulating, hydrophobic, sound-deadening, low density foam core that meets OEM requirement for flammability. Impact to payload 150-165 lbs. 2) Antenna Ground Plane, embedded bronze mesh including 8 integrated ground studs with ground straps. 3) Rear Door Options a) Horizontal 5052 Aluminum Barn Doors with pad lockable T -Handle minimum thickness of 0.125" prepped and Coated per Mil Standards MIL-P-53022 and MIL-DTL-64159 b) Vertical 5052 Aluminum (Flip-up Door) with pad Jockable T-Handle minimum thickness of 0.125" prepped and Coated per Mil Standards MIL-P- 53022 and MIL-DTL-64159 4) Independent Mounting Collar. 5052 Aluminum Mounting Collar with minimum thickness of 0.1875" with welded standoffs to assure gasket integrity if over torqued. a) Must have provisions for optional APES, Cargo Over-Pressurizer and wiring harness routing with aluminum cover plates prepped and Coated per Mil Standards MIL-P-53022 and MIL-DTL-64159 6) Interior Height - 40" minimum 7) Brackets - 5052 Aluminum rear mounting brackets prepped and Coated per Mil Standards MIL-P-53022 and MIL-DTL-64159 8) Hardware Fasteners - Dorrltech (prepped for paint adhesion) 9) Stainless Steel Door Hinges minimum 0.090" thick prepped and Coated per Mil Standards MIL-P-53022 and MIL-DTL-64159 10) Roof Load Limit - 250 pounds per square foot 11) Antenna Mount Hard Points - 10" x 10" machined 5052 aircraft aluminum NATO hard points with a minimum thickness of 0.875" prepped and Coated per Mil Standards MIL-P-53022 and MIL-DTL-64159. Cover plates provided. 12) CARC Paint - Applied to Mil Spec Standard MIL-DTL-61459 13) Written Installation Instructions - Included with each individual top 14) Warranty Support - 3 Year factory warranty 15) Local service and support 16) Training - On-Site "train the trainer" program 17) No wood products allowed in laminate schedule M1152 Standard Height Cargo Bed Cover (Requirements Document) 1) Shelter o Vacuum Assist Resin Transfer Molded. o.875" thickness in roof section. o Locally reinforced for antenna mounting. o Impact to payload 225-265 lbs. o Minimum dimensions 86.1 long x 22.3 high x 84.87 wide 2) Antenna Ground Plane o embedded bronze mesh. o 8 integrated ground studs with ground straps. 3) Rear Door o Vertical 5052 Aluminum (Flip-up Door) with pad lockable T-Handle minimum thickness of 0.125" prepped and Coated per Mil Standards MIL-P-53022 and MIL-DTL-64159 o Minimum Door Opening 22.5 inches tall x 51.50 wide 4) Independent Mounting Collar o 5052 Aluminum Mounting Collar with Adapter Plate. o Minimum thickness of 0.1875". 5) Interior Height o 40" minimum 6) Brackets o 5052 Aluminum rear and mid. o Prepped and Coated per Mil Standards MIL-P-53022 and MIL-DTL-64159 8) Hardware/Fasteners o Dorrltech coated (prepped for paint adhesion) 9) Stainless Steel Door Hinges o Minimum thickness - 0.090" o Prepped and Coated per Mil Standard MIL-P-53022 and MIL-DTL-64159 10) Roof Load Limit of 500 pounds 11) CARC Paint o Applied to Mil Spec Standard MIL-DTL-61459 12) Written Installation Instructions o Included with each individual top 13) Warranty, Provisioning and Technical Support o 2 Year factory warranty 14) Service /Support and Quality On-Site "Train the Trainer" program o LocalTechrricalSupport
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/NGB/DAHA31/W36M6701731025/listing.html)
 
Place of Performance
Address: 4105 Reedy Creek Rd, Raleigh, North Carolina, 27607, United States
Zip Code: 27607
 
Record
SN02219466-W 20100729/100727235821-b0d56bd74f96f2cb89d9454e325844c6 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.