Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF APRIL 30, 2010 FBO #3079
SOLICITATION NOTICE

65 -- Catheters used with the CARTO XP/EP Navigation and Ablation System located at Brooke Army Medical center (BAMC)Ft. Sam Houston, TX.

Notice Date
4/28/2010
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
Great Plains Regional Contracting Ofc, ATTN: MCAA GP L31 9V, 3851 Roger Brooke Drive, Fort Sam Houston, TX 78234-6200
 
ZIP Code
78234-6200
 
Solicitation Number
W81K0010T0110
 
Response Due
5/6/2010
 
Archive Date
7/5/2010
 
Point of Contact
Roland Jasso, 210-221-4964
 
E-Mail Address
Great Plains Regional Contracting Ofc
(roland.jasso3@amedd.army.mil)
 
Small Business Set-Aside
N/A
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. Solicitation W81k0010T0110 is issued as a request for quotation (RFQ). This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-40. This acquisition is unrestricted under NAICS code 339112 and the business size standard is 500 employees. Federal Acquisition Regulation (FAR) Clause 52.211-6 Brand Name or Equal applies to this acquisition. The requirements in this solicitation are: Description Catalog Code Qty - Unit Price Total CABLES BLUE CABLEC5MHREFMHS 5 _____ _____ RED CABLEC5MHNAVMHS 5 ______ _____ INTERFACE CABLE (RED)C10MR10MSTKS 5 ______ _____ INTERFACE CABLE (BLUE)M6MR10EPTRS 5 ______ _____ INTERFACE CABLE (RED/GREEN)C10MRMSTKDTCS5 ______ _____ Ablation Catheters CELSIUS THERMO COOL, F-TYPEDI7TCFLRT15 ______ _____ CELSIUS THERMO COOL, D-TYPEDI7TCDLRT15 ______ _____ NAVISTAR, D-TYPE, 4MMNS7TCDL174HS 20 ______ _____ NAVISTAR, F-TYPE, 4MMNS7TCFL174HS 20 ______ _____ NAVISTAR, D-TYPE, 8MMNS7TCF8L174HS 15 ______ _____ NAVISTAR, F-TYPE, 8MM NS7TCF8L174HS 15 ______ _____ Patches and Tubing REF STAR QUICK PATCHXRP6H 30 ______ _____ COOLFLOW IRRIGATION TUBINGCFT001 30 ______ _____ Diagnostic Catheters CS Catheter D-FBD710DF282RTS 20 ______ _____ CS Catheter F-JBD710FJ282RTS 20 ______ _____ CRISTA CATHD7A20131RT 8 _____ ______ LASSO 15MM FIXEDDL71015RT 7 _____ ______ LASSO 20MM FIXEDDL71020RT 7 _____ ______ LASSO 25MM FIXEDDL71025RT 7 _____ ______ Diagnostic Cables Yellow (up to 10 pole with Auto ID)CY1210CT 5 _____ _____ Yellow (up to 10 pole without Auto ID)CY1212CT 5 _____ _____ Green (Ultrasound)CG2025CT 5 _____ _____ Blue (CS Bi-Dir with Auto ID)CB3412CT 5 _____ _____ Blue (CS Bi-Dir without Auto ID)CB3410C 5 _____ _____ Blue (Lasso NAV with Auto ID)CB3434CT 5 _____ _____ Ablation Cables Red (Celsius catheters)CR3410CT 5 _____ _____ Red (For current NAV catheters)CR3425CT 5 _____ _____ Red (EZSteer ThermoCool)CR3434CT 1 _____ _____ Stockert (connects PIU to Stockert)D129705 5 _____ _____ Ablation Catheters SAME AS CARTO XP Patches and Tubing Carto 3 External Reference PatchesCREFP6 60 ____ _____ SAME TUBING AS CARTO XP Diagnostic Catheters CS Bi-Dir with Auto IDBD710FJ282CT 60 ____ _____ Lasso Decapolar with Auto ID, 15mm loopD7L1015CT 12 ____ _____ Lasso Decapolar with Auto ID, 20mm loopD7L1020CT 12 ____ _____ Lasso NAV 20 pole with Auto IDLN222515CT 12 ____ _____ SALIENT CHARACTERISTICS: 1. Provides connectivity between RF generator and patient interface unit; certified for 10-re-sterilization cycles 2. Allows physician to create-RF-Controlled lesions with 1mm of accuracy 3. Provides ablation catheter location within 1mm 4. Provides a timing reference for creation of 3D timing map; allows physician to validate RF ablation of pulmonary vein potentials. 5. Provides QuickConnect capability to shorten procedure time; validated for up to 20-re-sterilizations cycles. 6. Provides accurate catheter location within 1mm; allows for display of up to 5 catheters. 7. Provides auto identification to shorten procedure time; allows for fast anatomical mapping of chamber. Note: These products are used for the CARTO XP/EP Navigation and Ablation System located at Brooke Army Medical Center (BAMC). This requirement is for the Brooke Army Medical Center, Fort Sam Houston, Texas. All reference clauses throughout this solicitation can be viewed by accessing website http://farsite.hill.af.mil/. Products will be provided to Brooke Army Medical Center, (BAMC), Fort Sam Houston, TX. FAR provision 52.212-1 Instructions to Offerors Commercial applies to this acquisition to include the following addenda: All offerors are cautioned that if selected for award, they must be registered with the Central Contractor Registration (CCR) program. The CCR can be accessed via the internet at www.ccr.gov/. Confirmation of CCR registration will be validated prior to awarding a contract. Provide the following with your quote. (1). Technical Capability: If providing an equal product, comply with FAR 52.211-6 Brand Name or Equal. Explain how your company will meet the salient characteristics 1 through 7. NOTE: Statements that the offeror understands, can or will comply with all specifications, or statements paraphrasing the specifications or parts thereof, or phrases such as standard procedures will be used or well known techniques will be used will be considered insufficient. Insufficient explanations of how your company will comply with the above listed items of this solicitation may cause your quote to b e determined unacceptable. (2). Price. Unit and Total price for each line item. Evaluation Process: All quotes will be evaluated in accordance with the following criteria: 52.212-2 Evaluation Commercial Items (JAN 1999), to include the following addenda: (a) The following factors will be used to evaluate quotes: 1.Technical Capability and Price. 2.All quotes will be evaluated on overall technical capability. The award decision will be based on the Lowest Price Technically Acceptable (LPTA), quote. All or none basis [Vendors shall include a completed copy of FAR provision 52.212-3 OFFEROR REPRESENTATIONS AND CERTIFICATIONS COMMERCIAL ITEMS (AUG 2009) ALTERNATE I (APR 2002), with their offer. The provision can be downloaded by accessing the website http://farsite.hill.af.mil/listed]. 52.212-4 CONTRACT TERMS AND CONDITIONS COMMERCIAL ITEMS (MAR 2009); 52.203-3 GRATUITIES (APR 1984) (Over SAT) (Non-personal services), 52.203-6 RESTRICTIONS ON SUBCONTRACTOR SALES TO THE GOVERNMENT (SEP 2006) ALTERNATE I (OCT 1995),52.203-12 LIMITATION ON PAYMENTS TO INFLUENCE CERTAIN FEDERAL TRANSACTIONS (SEP 2007) (Over SAT), 52.204-4 PRINTED OR COPIED DOUBLE-SIDED ON RECYCLED PAPER (AUG 2000) (Over SAT), 52.222-3 CONVICT LABOR (JUN 2003), 52.222-19 CHILD LABOR-COOPERATION WITH AUTHORITIES AND REMEDIES (AUG 2009) (Supply Buy), 52.222-50 COMBATING TRAFFICKING IN PERSONS (FEB 2009) (For OCONUS, Use ALTERNATE I) (AUG 2007), 52.223-3 HAZARDOUS MATERIAL IDENTIFICATION AND MATERIAL SAFETY DATA (JAN 1997) (Contractors supplies), 52.225-13 RESTRICTIONS ON CERTAIN FOREIGN PURCHASES (JUN 2008), 52.232-36 PAYMENT BY THIRD PARTY (MAY 1999) (GPC), 52.233-3 PROTEST AFTER AWARD (AUG 1996), 52.233-4 APPLICABLE LAW FOR BREACH OF CONTRACT CLAIM (OCT 2004), 52.242-13 BANKRUPTCY (JUL 1995) (Over SAT), 252.201-7000, 252.203-7000 REQUIREMENTS RELATING TO COMPENSATION OF FORMER DOD OFFICIALS (JAN 2009), 252.203-7002, REQUIREMENT TO INFORM EMPLOYEES OF WHISTLEBLOWER RIGHTS (JAN 2009), 252.204-7003 LEVIES ON CONTRACT PAYMENTS (DEC 2006), 52.252-2 CLAUSES INCORPORATED BY REFERENCE (FEB 1998), 252.212-7001 CONTRACT TERMS AND CONDITIONS REQUIRED TO IMPLEMENT STATUTES OR EXECUTIVE ORDERS APPLICABLE TO DEFENSE ACQUISITIONS OF COMMERCIAL ITEMS (JUL 2009) (DEVIATION), 52.212-5 CONTRACT TERMS AND CONDITIONS REQUIRED TO IMPLEMENT STATUTES OR EXECUTIVE ORDERS -- COMMERCIAL ITEMS (DEC 2009) (DEVIATION), 52.212-1 INSTRUCTIONS TO OFFERORS COMMERCIAL ITEMS (JUN 2008), 52.211-6 BRAND NAME OR EQUAL (AUG 1999), 52.252-1 SOLICITATION PROVISIONS INCORPORATED BY REFERENCE (FEB 1998), 252.212-7000 OFFEROR REPRESENTATIONS AND CERTIFICATIONS--COMMERCIAL ITEMS (JUN 2005) (Over SAT), 52.252-1 SOLICITATION PROVISIONS INCORPORATED BY REFERENCE (FEB 1998). The closing date and time of this solicitation is 6 May 2010, 11:00 A.M. Central Standard Time. Price quotes shall be submitted on company letterhead and signed by a company representative. Email quotes to Great Plains Regional Contracting Office (210) 221-5359. Paper copies of this solicitation will not be issued and telephone requests or FAX requests for the solicitation will not be accepted. Point of contact for this solicitation: Roland Jasso, phone (210) 221-4964; e-mail: roland.jasso3@amedd.army.mil
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/MEDCOM/DADA09/W81K0010T0110/listing.html)
 
Place of Performance
Address: Great Plains Regional Contracting Ofc ATTN: MCAA GP L31 9V, 3851 Roger Brooke Drive Fort Sam Houston TX
Zip Code: 78234-6200
 
Record
SN02134438-W 20100430/100428234917-0860fa9dbea400c7bebe8756d031060e (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.