SOLICITATION NOTICE

Y -- Ice Harbor South Shore Storage Building

Notice Date
4/21/2010
 
Notice Type
Presolicitation
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
USACE District, Walla Walla, 201 N. Third Avenue, Walla Walla, WA 99362-1876
 
ZIP Code
99362-1876
 
Solicitation Number
W912EF10B0008
 
Response Due
7/1/2010
 
Archive Date
8/30/2010
 
Point of Contact
Elaine M. Vandiver, 509-527-7221
 
E-Mail Address
USACE District, Walla Walla
(elaine.m.vandiver@usace.army.mil)
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
Construct a pre-engineered metal building in the storage area on the south shore of the Snake River (Walla Walla County) downstream of the Ice Harbor Lock and Dam near the City of Pasco, Franklin County, Washington. General requirements: Construct a 140 foot by 80 foot pre-engineered metal building, consisting of two 60-foot by 80-foot concrete aprons on each side of the new building (along the short axis of the building). The eave height is 26 feet and the overall building height is 33 feet and 3 inches. The pre-engineered metal building system shall be provided by a single manufacturer and shall include all components and assemblies that form a complete building. The building shall have structural steel main building frames, and secondary framing including purlins and girts, engineered and fabricated by the building systems supplier. The building shall have vertical steel walls and a gable roof system including gutters and downspouts. The building shall consist of single-span or multiple-span structures with rigid frames in the transverse direction (with no interior columns within the clear span of the building). The building shall have two 20 feet by 20 feet and one 12 feet by 14 feet insulated sectional overhead doors, four exterior personnel doors and ten louvers (long axis four on each side--4 feet wide by 6 feet high-- and one on each short axis--4 feet wide by 4 feet high) shall be included with the metal building system. Exterior lighting protective bollards and security fencing (fifty feet away from the long axis of the building and from each concrete apron edge) with two 24 feet and two 12 foot vehicle gates shall be provided by the contractor. The requirement will include electrical power connecting into a local power source (PSP1) within Ice Harbor Lock & Dam Project boundary through a switch gear. The power lines and communication lines will be brought to the new building via a trenched and buried conduit with pull boxes. The contractor shall provide a concrete utility vault (6 feet wide by 4 feet deep by 5 feet and 6 inches high) for power and communication lines. Primary power 480 volts/3-ph from PSP1 to the building interior panel box service then to interior transformer. Interior electrical items: Enclosure - COMM. NEMA 12, 2 feet wide by 3 feet high by 10 inches deep; Panel box Service 480 V / 3-Ph, 400 A; Interior transformer 75 KVA, 480, 3-Ph primary - 208/120 V, 3-Ph secondary; Panel box Branch 280 / 120 V / 3-Ph / 4 W / 200 A. Solicitation number W912EF-10-B-0008 will be posted to the FBO website on or about May 21, 2010. Important Note: The FedBizOpps Response Date listed elsewhere in this synopsis is for FedBizOpps archive purposes only. The Invitation for Bid closing date will be contained in the solicitation and any solicitation amendments that may be issued. A site visit will be offered approximately 2 weeks after the solicitation is made available to bidders. See solicitation for details about the site visit. NAICS code for this project is 236220, and the small business size standard is $33,500,000 average annual receipts. Estimated magnitude of construction is between $1,000,000 and $5,000,000. The solicitation will be set aside 100% for Service Disabled Veteran Owned Small Business. When available, the solicitation documents for this project will be available via FedBizOpps at www.fbo.gov. No CDs or hardcopies of the solicitation will be available. Offerors are responsible for checking the referenced page for any update(s) to the notice. The Government is not responsible for any loss of internet connectivity or for an offeror's inability to access the document posted at the referenced website. To obtain automatic notifications of updates to this solicitation, you must log in to www.fbo.gov and add the solicitation to your Watch-list. If you would like to list your firm so others can see you are an interested vendor, you must click the Add Me To Interested Vendors button in the listing for this solicitation.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA68/W912EF10B0008/listing.html)
 
Place of Performance
Address: Ice Harbor Lock & Dam (USACE Walla Walla District) 1215 East Ainsworth Pasco WA
Zip Code: 99301-6076
 
Record
SN02128461-W 20100423/100421235116-80a7ac5239167909045c82395fc84881 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.