N -- RECOVERY--N--PROJECT NUMBER 29900, Install Ground Source Heat Pump, Bldg 3-3327

Notice Date
3/16/2010
 
Notice Type
Presolicitation
 
NAICS
541512 — Computer Systems Design Services
 
Contracting Office
USACE HNC, Huntsville, P. O. Box 1600, Huntsville, AL 35807-4301
 
ZIP Code
35807-4301
 
Solicitation Number
W912DY-10-N-0224
 
Response Due
3/30/2010
 
Archive Date
5/29/2010
 
Point of Contact
Katrena Winchester, 256-895-1145
 
E-Mail Address
USACE HNC, Huntsville
(katrena.h.winchester@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
RECOVERY-THIS NOTICE IS PROVIDED FOR INFORMATION PURPOSES ONLY. THIS OPPORTUNITY IS AVAILABLE ONLY TO CONTRACTORS UNDER THE UMCS III PROGRAM. This opportunity is available only to the following Unrestricted Multiple Award Task Order Contractors (MATOC): W912DY-09-D-0035, AMERESCO POC Andy Rubin arubin@ameresco.com; W912DY-09-D-0036, Honeywell Products, Inc. POC David Peirce david.peirce@honeywell.com; W912DY-09-D-0037, Johnson Controls Building Automation POC Carmen Thompson carmen.p.thompson@jci.com; W912DY-09-D-0038, Siemens Government Services, Inc. POC Benjamin Pewtress benjamin.pewtress@siemensgovt.com; W912DY-09-D-0039, TAC Americas POC Daryl Glass daryl.glass@tac.com; W912DY-09-D-0040, TENG & Associates, Inc. POC Donna Floerchinger floerchingerD@teng.com; W912DY-09-D-0041, Trane U.S., Inc. POC Barry McCaslin barry.mccaslin@trane.com; and W912DY-09-D-0041, Williams Electric Company, Inc. POC Aubrey Gouner aubrey@williamselectric.com. This task order is to Provide RCx services meeting the requirements for LEED"-EB O&M. including but not limited to: Perform a comprehensive, whole-building evaluation/investment-grade audit of all mechanical and electrical systems and components, as well as the building envelope, to identify and quantify each deficiency and energy/water conservation measure (ECM) needed to correct each deficiency. Obtain available building utility information, mechanical/electrical drawings, test reports, current controls sequences, and HVAC operations and maintenance (O&M) data. Document the breakdown of energy use in the building. Prepare a detailed Systems Operating Manual for the building. Provide a training syllabus and classroom or on-site training for MCBH O&M personnel in the efficient operation and maintenance of each facility. The commissioning authority (CA) firm shall have a team leader that is a Certified Commissioning Professional (CCP) by the Building Commissioning Association or Certified Commissioning Authority (CxA) by AABC Commissioning Group. The Contractor shall furnish the materials and labor required to Perform Retro-Commissioning in building 3-3327, Golden Knights Facility at Ft. Bragg, NC.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA87/W912DY-10-N-0224/listing.html)
 
Place of Performance
Address: Ft. Bragg Ft. Bragg NC
Zip Code: 28307
 
Record
SN02094194-W 20100318/100316235858-74309511f2d618665f2f6bfabc83874e (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.