Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MARCH 18, 2010 FBO #3036
SOURCES SOUGHT

99 -- Interior Finishes (project #5)

Notice Date
3/16/2010
 
Notice Type
Sources Sought
 
NAICS
238190 — Other Foundation, Structure, and Building Exterior Contractors
 
Contracting Office
Department of Labor, Employment Training Administration, Whitney Young Job Corps Center, 8460 Shelbyville Road, Simpsonville, Kentucky, 40067
 
ZIP Code
40067
 
Solicitation Number
62906
 
Archive Date
5/6/2010
 
Point of Contact
Jenifa M Glore, Phone: 5027223600, Carolyn Savko, Phone: 502-722-3473
 
E-Mail Address
glore.jenifa@jobcorps.org, savko.caroln@jobcorps.org
(glore.jenifa@jobcorps.org, savko.caroln@jobcorps.org)
 
Small Business Set-Aside
N/A
 
Description
The Whitney M. Young Job Corps Center is soliciting bids for a Interior Finishes (Project #5) with a mandatory walk-thru on March 23, 2010. Small business are encourged to bid. The intent of this Scope of Work is to correct the interior finishes issues at the Whitney M. Young Job Corps Center. The Center interior finishes issues include: Ventilation: • Provide a 200 CFM ceiling exhaust fan with integral brackdraft damper and 20 LF of 6" diameter duct. Provide two air intake grilles: one in the janitor closet, and one in the storeroom. Connect the two registers to the common riser with 6" diameter duct and appropriate fittings. Run the duct through the concrete third floor. Extend the duct 1 LF through the roof and provide appropriate roof cap. Energize from lighting circuit, using the existing switch and 20 LF of 3 #12 in ½" EMT. Provide for drywall repair if necessary. • Provide a wall mounted 100 CFM exhaust fan with integral backdraft damper in each toilet room. Connect the units to the lighting circuits utilizing the existing light switches for fan operation. Rehab Restrooms: The interior finish materials shall be ceramic tile floors and wainscot, and drywall, and drywall walls and ceiling. New layout shall include a handicap toilet and sink in each restroom. Total square footage is approximately 100 SF. Provide one audio-visual fire alarm device (15 cd) in each restroom (2 total) and connect to the existing fire alarm system. Repair and Replace: • Install one floor drain in each of the four (4) laundry rooms. Test the laundry floors to determine if they have a slope to it, establish a location for a new floor drains, tie in to the other laundry drain plumbing after removing the necessary amount of concrete. (4-core drill, 4 new floor drain units, 160 LF of 4' PVC pipe) • Replace corroded junction box with a functionally equivalent non-corrosive metallic unit suitable for use by code in wet locations. Provide myers hubs for conduit connections. The new unit shall have gasketed cover and conduit opening to maintain the water proof integrity of the interior. Coordinate with deficiency 52357 which addresses the relocation of the nearby gas line. For cost estimation purposes, use: one Nema type 4X junction box 13-1/2" Hx 10 W x 7-3/16" D in size, 12 hours labor for one electrician. Paint: • Hire a lead-based paint inspector to collect paint chip samples of the paint prior to removal. Follow OSHA regulations (29 CFR 1926.62) regarding lead-based paint during removal, if necessary. Remove existing paint and repaint approximately 30% of surface area, approximately 4000 SF.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOL/ETA/WhitneyYoungJcc/62906/listing.html)
 
Place of Performance
Address: Whitney M. Young Job Corps, 8460 Shelbyville Road, Simpsonville, Kentucky, 40067, United States
Zip Code: 40067
 
Record
SN02093239-W 20100318/100316234847-b1a55a276ade1905e745193194e79fa1 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.