59 -- Generator Rewind Units 5, 7, and 8, Big Bend Powerhouse, Fort Thompson, SD.

Notice Date
3/11/2010
 
Notice Type
Presolicitation
 
NAICS
811310 — Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
 
Contracting Office
USACE District, Omaha, 1616 Capital Ave, Omaha, NE 68102-4901
 
ZIP Code
68102-4901
 
Solicitation Number
W9128F09R0089
 
Response Due
5/18/2010
 
Archive Date
7/17/2010
 
Point of Contact
Neil Herman, (402) 995-2057
 
E-Mail Address
USACE District, Omaha
(neil.f.herman@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
On or about 25 March 2010, this office will issue Request for Proposals for design and construction of the GENERATOR REWIND UNITS 5, 7 AND 8, BIG BEND POWERHOUSE, FORT THOMPSON, SD. The solicitation will close on or about 18 May 2010. This solicitation is UNRESTRICTED AND OPEN TO BOTH LARGE AND SMALL BUSINESS PARTICIPATION. A tentative site visit date will be announced. Provisions in the solicitation documents will provide detailed information (meeting place, time, points of contact, and access requirements). Point of contact for the site visit is Trevor McDonald, US Army Corps of Enigineers, Big Bend Project, 605-245-2331 x3002, Trevor.R.McDonald@USACE.Army.mil. DO NOT submit requests for plans and specifications to the site visit personnel listed above. See Obtaining Solicitation Documents below. Project Description: (Approx. quantities) This work consists of design, manufacture, testing and delivery of stator laminations, stator windings, and accessories for 3 units with the 3rd unit being optional. It will require disassembly the Units, alignment checks, and removal of existing stator windings, and stator cores. The Units will then have the newly designed and manufacture stator cores and windings installed. This will require stacking the laminations, installing the windings, making all connections between the coils, and testing. Additionally, the units rotors will be cleaned, inspected, tested and the field leads reinsulated. Lastly, air coolers will be furnished and installed on the three units. Units will be completely reassembled and final tests will be performed insuring unit integrity. The existing units are 81.8RPM, 13.8kV, and 62MVA with 115% overload ability. The existing units have a total of 384 coils and slots The estimated construction cost of this project is between $15,000,000 and $20,000,000. The Contractor will be required to commence work within 10 days after notice to proceed and complete the work by 3 years after receipt of Notice to Proceed. Provisions will be included for liquidated damages in case of failure to complete the work in the time allowed. Performance and payment bonds will be required. Bonding documents including the power of attorney shall bear an original signature by an officer of the surety. Bidders (Offerors): Please be advised of on-line registration requirement in Central Contractor Registration (CCR) database https://www.bpn.gov/ccr/default.aspx and directed solicitation provisions concerning electronic annual On-line Representations and Certifications (ORCA) at https://orca.bpn.gov. Representations and certifications are required to be updated annually as a minimum to keep information current, accurate and complete. The electronic annual representations and certifications are effective until one year from date of submission or update to ORCA. Obtaining Solicitation Documents: Solicitation documents will be posted to the web via Federal Business Opportunities (www.fbo.gov). Find solicitation announcement in Fed Biz Opps (www.fbo.gov) 1. Use the Quick Search to locate the project (by entering all or part of the solicitation number) or use the advanced search features offered in the Find Opportunities (large arrow in the middle of the page) or use the Opportunities tab followed by the Advanced Search tab. 2. By using the login feature, it allows additional search features and allows you to keep your searches. Login might be required on some solicitations that are considered restricted. 3. Once you have located your project, click on link to solicitation to view the project. Files may be downloaded from the column on the right side reading All Files or from the Packages tab. 4. If you want other vendors, sub-contractors or contractors to contact you, click on the Interested Vendors tab and then Add me to Interested Vendors link at the bottom of the page. Questions regarding contractual matters should be made to: Neil Herman 402-995- 2057. Telephone calls regarding Small Business matters should be made to: 402-995- 2910. Telephone calls on contents of drawings and specifications should be made to the Project Manager at: 402-995-2497 or Specification Section at: 402-995-2184.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA45/W9128F09R0089/listing.html)
 
Place of Performance
Address: USACE District, Omaha 1616 Capital Ave, Omaha NE
Zip Code: 68102-4901
 
Record
SN02089734-W 20100313/100311235120-44d084c17f20df9f2f4e925632f9bcee (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.