Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MARCH 03, 2010 FBO #3021
SOLICITATION NOTICE

20 -- TOW WIRE

Notice Date
3/1/2010
 
Notice Type
Presolicitation
 
NAICS
334111 — Electronic Computer Manufacturing
 
Contracting Office
Department of the Navy, Military Sealift Command, MSFSC Norfolk, Building SP-64, 471 C Street, Norfolk, Virginia, 23511, United States
 
ZIP Code
23511
 
Solicitation Number
N40442-10-T-4013
 
Archive Date
3/20/2010
 
Point of Contact
ALFRED TURNER, Phone: 7574435965, EDDRIAN LOGAN, Phone: 7574435883
 
E-Mail Address
alfred.turner1@navy.mil, eddrian.logan@navy.mil
(alfred.turner1@navy.mil, eddrian.logan@navy.mil)
 
Small Business Set-Aside
N/A
 
Description
Military Sealift Fleet Support Command has a requirement for 8500 Ft. 2 ¼ TOW WIRE. SEE SPECS BELOW. Material to be shipped to Naval Station Norfolk, Va. ARS-50 Class Tow Wire: 2 1/4” diameter 3000 foot length EIPS - (Extra Improved Plow Steel) Drawn Galvanized, performed. Regular (R.Hd) lay. IWRC – Independent Wire Rope Core. Type I Class 3 Construction 6 6 X 37 (Warrington Seale) Procured IAW Specification RRW410- Documentation of all test results required by RRW410 from each master reel of wire shall be submitted. ABS Proof Test certification shall be provided. The tow wire shall have a CLOSED zinc-poured galvanized socket- Type B one end and a permanent seizing on the other. Type B sockets to be procured IAW Specification RRS550 and documentation of results of tests required by RRS550 shall be delivered with each wire. Documentation of pull test to 40% of wire strength required. Wire Rope cable will be wound on reels, closed socket first. Reel drums shall be modified as required to allow the closed socket to be inserted into the drum and held so wire can be uniformly wound and tightly secured. Presence of the closed socket must be verifiable by visual exam. w/o disturbing stowage of wire. Reel shall be clearly marked on each side with diameter and length of wire as follows: “2 1/4 in.” X 3000 ft w/closed socket” ATF-166 Class Tow Wire: 2 1/4” diameter 2500 foot length EIPS - (Extra Improved Plow Steel) Drawn Galvanized, performed. Regular (R.Hd) lay. IWRC – Independent Wire Rope Core. Type I Class 3 Construction 6 6 X 37 (Warrington Seale) Procured IAW Specification RRW410- Documentation of all test results required by RRW410 from each master reel of wire shall be submitted. ABS Proof Test certification shall be provided. The tow wire shall have a CLOSED zinc-poured galvanized socket- Type B one end and a permanent seizing on the other. Type B sockets to be procured IAW Specification RRS550 and documentation of results of tests required by RRS550 shall be delivered with each wire. Documentation of pull test to 40% of wire strength required. Wire Rope cable will be wound on reels, closed socket first. Reel drums shall be modified as required to allow the closed socket to be inserted into the drum and held so wire can be uniformly wound and tightly secured. Presence of the closed socket must be verifiable by visual exam. w/o disturbing stowage of wire. Reel shall be clearly marked on each side with diameter and length of wire as follows: “2 1/4 in.” X 3000 ft w/closed socket” To request a copy of the solicitation, email alfred.turner1@navy.mil or fax request to 757.443.5979. Estimated issue date for this solicitation is on/about 05 Mar 2010. After issuance, solicitation may be obtained by accessing the contracts section of the MSC website, http://www.msc.navy.mil
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/87a04598b3fd010e2d32cd0cde4586ef)
 
Record
SN02079239-W 20100303/100301234826-87a04598b3fd010e2d32cd0cde4586ef (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.