SOLICITATION NOTICE
Z -- RECOVERY--Z--PROJECT NUMBER 38699, Upgrade Fire Protection Sys Building 33-630
- Notice Date
- 1/28/2010
- Notice Type
- Presolicitation
- NAICS
- 238210
— Electrical Contractors and Other Wiring Installation Contractors
- Contracting Office
- Pine Bluff Arsenal Contracting Office (RI-CC), ATTN: CCRC-ISP, 10-020 Kabrich Circle, Pine Bluff, AR 71602-9500
- ZIP Code
- 71602-9500
- Solicitation Number
- W911RP10R0010
- Response Due
- 2/12/2010
- Archive Date
- 4/13/2010
- Point of Contact
- CALVIN.HICKMAN, 870-540-3016
- E-Mail Address
-
Pine Bluff Arsenal Contracting Office (RI-CC)
(calvin.hickman@us.army.mil)
- Small Business Set-Aside
- N/A
- Description
- Upgrade Fire Protection Sys Building 33-630 South Side consist of removal of current Fire Protection System for the South Side Building 33-630 removal consist of all fire control panels and associated conduit and wiring, tamper switches, power supplies, alarm transmittals etc., removal of ultraviolet light (UV) detectors, and removal of heat detectors. Contractor shall inspect and evaluate the fire system control valves, spray nozzles and solenoids, then provide and install new fire control panels associated wire and conduit, tamper switches and power supplies, alarm transmittals etc., provide and install new UV/IR detectors, provide new heat detectors, conduct acceptance test of the new fire detection and alarm system, provide Technical and Operating Manuals, provide As Built drawings, and conduct operator and maintenance training with all work being completed within 180 days after issuance of notice to proceed. Upgrade Fire Protection Sys Building 33-630 North Side and installation of a new Fire Protection System removal consist of removing all fire control panels and associated conduit and wiring, tamper switches, power supplies, alarm transmittals etc., removal of ultraviolet light (UV) detectors, and removal of heat detectors. Contractor shall inspect and evaluate the fire system control valves, spray nozzles and solenoids, remove the building local fire notification system including the bells and wiring, provide and then install new fire control panels and fire transceiver panel (FTR) provide and install new wiring in existing conduit to the maximum extent practicable, unless otherwise indicated, provide and install new tamper switches, power supplies, alarm transmittal etc., provide and install new UV/IR detectors, provide and install new heat detectors, provide and install new building local fire notification system including horns, strobes, pull stations and wiring, conduct acceptance test of the new fire detection and alarm system, provide Technical and Operating Manuals, provide As Built drawings, and conduct operator and maintenance training with all work being completed within 180 days after issuance of notice to proceed. The type of contract shall be firm fixed price. The South Side Building 33-630 portion of this project is an (American Recovery and Reinvestment Act of 2009 Project, Project Number 38699). FOB Destination, Pine Bluff Arsenal, AR. Acquisition is being conducted utilizing full and open competition. All responsible sources may submit a proposal which shall be considered by the agency. Solicitation will issue on or after 13 February 2010 with a closing date on or after 15 March 2010. Requests for the solicitation package must be in writing, via facsimile to 870-540-3730 or via e-mail to calvin.hickman@us.army.mil. Ensure solicitation number W911RP-10-R-0010 is listed in the subject line on all solicitation requests. Additionally, companies full mailing address, telephone and fax numbers, and email addresses where available should be listed on all requests. Email request that do not contain the solicitation number in the subject line will be deleted without review. Electronic Proposals are not acceptable; proposals shall be mailed to arrive by the time specified in the solicitation to the address specified in the solicitation. The contract resulting from this procurement will be awarded to the responsible Offeror whose offer, conforming to the solicitation requirements; will be most advantageous to the Government, price and other factors considered. Offerors shall submit all technical questions regarding this solicitation to the Contracting Officer, in writing, no later than 15 days after issuance of this Request for Proposal. Questions may be sent via facsimile or email, again the solicitation number MUST BE referenced in the subject line on any correspondence. Verbal questions will not be addressed. Point of contact is Calvin S. Hickman, Contract Specialist, 870-540-3016.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/66ffffa6ceb43a120c3e6340a3715f59)
- Place of Performance
- Address: Pine Bluff Arsenal Contracting Office (RI-CC) ATTN: CCRC-ISP, 10-020 Kabrich Circle Pine Bluff AR
- Zip Code: 71602-9500
- Zip Code: 71602-9500
- Record
- SN02051957-W 20100130/100128235020-66ffffa6ceb43a120c3e6340a3715f59 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |