Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JANUARY 23, 2010 FBO #2982
SOURCES SOUGHT

Z -- Mill Creek Diversion Gate Operator & Electrical Upgrades

Notice Date
1/21/2010
 
Notice Type
Sources Sought
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
Department of the Army, U.S. Army Corps of Engineers, USACE District, Walla Walla, Attn: CENWW-CT, 201 North 3rd Avenue, Walla Walla, Washington, 99362-1876, United States
 
ZIP Code
99362-1876
 
Solicitation Number
W912EF-10-R-SS14
 
Archive Date
2/1/2010
 
Point of Contact
Phyllis Buerstatte, Phone: 509-527-7211, Jani C Long, Phone: 509-527-7209
 
E-Mail Address
Phyllis.L.Buerstatte@usace.army.mil, jani.c.long@usace.army.mil
(Phyllis.L.Buerstatte@usace.army.mil, jani.c.long@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
The US Army Corps of Engineers, Walla Walla District is seeking sources for a construction project entitled, Mill Creek Diversion Gate Operator and Electrical Upgrades. This will be a firm-fixed-price contract. Place of performance is Walla Walla, Washington. Construction magnitude is between $250,000 and $500,000. A bid guarantee of 20% will be required. 100% Performance and payment bonds will be required. The Statement of Work includes the following: -Furnish all labor, equipment, material, supplies, and incidentals and perform all work necessary to install four new motorized intake gate actuators and upgrade an electrical system from single-phase to three-phase. -The electrical upgrades include 1) remove a pre-cast concrete shed, 2) install a small pre-fabricated electrical building, 3) provide a compatible three-phase mobile generator, 4) install three light poles, 5) relocate control panels, 6) bury conductors in a new trench passing under pavement, irrigated park lawn, vegetation, and soils that contain cobble-size rock, 7) relocate and rewire existing electrical circuits on and around the dam, 8) install a variety of small new electrical equipment, and 9) perform commissioning of the system. Work shall be coordinated with the Corps of Engineers to minimize power outages. -Deliverables include an Operating & Maintenance manual. Construction performance period is during the summer. The construction period is anticipated to be July to September, 2010 and contain strict schedule requirements. If the system is not operational by a pre-determined deadline, damages are expected to be significant for each calendar day of delay. All physical work is outside. Average summer temperature in the Walla Walla vicinity is 75 degrees Fahrenheit, with high temperatures exceeding 100 degrees Fahrenheit. Contractor must have technical capabilities and management experience to orchestrate a variety of labor crafts, construction activities, and subcontractors with a high degree of efficiency in order to meet the work window constraint. Work conditions include elevated work and confined spaces. Contractor must have a past performance history of work similar to the work required. Contractor is required to follow the procedures in the Army Corps of Engineers Safety Manual, at http://www.usace.army.mil/CESO/Documents/EM385-1-1FINAL.pdf This sources-sought announcement is issued for the purpose of identifying HubZone or Service Disabled Veteran Owned small business concerns with the capability to accomplish the work. Only those firms who respond to this announcement by submitting a statement of their current or past technical experience (what the firm has done) and current or past performance (how well the firm did it) similar to or the same as the requirements stated above, will be used in the determination of whether to set aside this requirement or open it to unrestricted competition. Include your firm's bonding capacity and a statement indicating your business type (HUBZone or Service Disabled Veteran Owned small business). The NAICS Code for this project is 238210 and the associated small business size standard is $14 million in average annual receipts. Please send your response to Phyllis Buerstatte, Contract Specialist, 201 North 3rd Avenue, Walla Walla, Washington 99362 or email responses to Phyllis.L.Buerstatte@usace.army.mil Your response to this notice must be received on or before close of business on January 29, 2010.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA68/W912EF-10-R-SS14/listing.html)
 
Place of Performance
Address: Mill Creek Dam, Walla Walla, Washington, 99362, United States
Zip Code: 99362
 
Record
SN02046901-W 20100123/100121235346-c67cde4a20881e8f661fbd49af9ff9c5 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)