Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JANUARY 06, 2010 FBO #2965
SOLICITATION NOTICE

30 -- RECOVERY--30--PROJECT NUMBER 17560, Stockton Lake, MO Rehabilitate the station service distribution system and main unit breakers

Notice Date
1/4/2010
 
Notice Type
Presolicitation
 
NAICS
811310 — Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
 
Contracting Office
US Army Engineer District, Kansas City, ATTN: CENWK-CT, 700 Federal Building 60l East 12th Street, Kansas City, MO 64106-2896
 
ZIP Code
64106-2896
 
Solicitation Number
W912DQ10R1008
 
Response Due
2/2/2010
 
Archive Date
4/3/2010
 
Point of Contact
Andre D. Vasseur, 816-389-3435
 
E-Mail Address
US Army Engineer District, Kansas City
(andre.d.vasseur@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
The Government shall be issuing a Request for Proposal W912DQ-10-R-1008 for a firm Fixed Price Service Contract with Construction for services to rehabilitate the station service distribution system and main unit breakers. All equipment described below is Contractor-furnished except for the GSU transformer (recd under a separate contract). Stockton Power Plant is located in Stockton, MO and has a single turbine-generator unit. a. Contractor design of the equipment, systems, and installation, as specified herein, including preparation of drawings and design calculations for load study, short circuit study, voltage drop for 480 volt feeders, voltage drop for cable bus, arc flash hazard, settings for relays and overcurrent protection, CO2 system upgrade, site civil design, and seismic calculations. b. Replacement in kind of the Station Service 480 volt Main Distribution Board and the six Distribution Centers, including all circuit breakers, relays, starters, and controls to match existing functions. c. Replacement in kind of the dry-type station service. d. Replacement in kind of 480 volt Distribution Centers (Motor Control Centers) 1P, 2P, 3P, 4P, 5P, and 6P in the powerhouse and Distribution Center (Panelboard) 7P in the switchyard, complete with source feeders and starters. e. Replacement in kind of the diesel engine-generator set, including relaying scheme for automatic switchover in the Main Distribution Board (an automatic transfer switch shall not be used). f. Replacement in kind of the DC and Preferred AC system, including batteries, chargers, distribution boards and breakers, and new static inverters. g. Replacement of the 13.8kV vacuum Main Unit Breaker (MUB) and the Station Service source tap circuit breaker with new vacuum circuit breakers as specified in SECTION 26 13 00.00 26, with one spare breaker furnished for each. h. Replacement and modifications to the existing Instrumentation Boards and Recorder Board. i. Provision of CO2 system refurbishment. j. Provision of the new High Resistance Ground (HRG) system. k. Replacement in kind of the non-segregated bus between the new MUB and the powerhouse wall penetration. l. Provision of the new outdoor cable bus between the powerhouse wall penetration and the Government-furnished GSU transformer in the switchyard, including weatherproof enclosure and internal bus heaters, structural supports, and connection to non-segregated bus at the powerhouse wall penetration. m. Installation of the Government-furnished oil-filled 55MVA Generator Step-Up (GSU) transformer in the switchyard, including: all related site preparation; reinforced concrete pad; seismic anchoring; oil containment; HV and LV connections; alarms, controls, relaying, and associated connections to the powerhouse; grounding loop for the switchyard extension and connection to existing grounding grid. n. Preparation of O&M Manuals. o. Preparation of As-Constructed Drawings. This list is a general summary of the requirements and is not all inclusive.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA41/W912DQ10R1008/listing.html)
 
Place of Performance
Address: US Army Engineer District, Kansas City ATTN: CENWK-CT, 700 Federal Building 60l East 12th Street Kansas City MO
Zip Code: 64106-2896
 
Record
SN02034561-W 20100106/100104235817-40cca0b10bfbe80384ed0ba4dfc3de3f (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers