N -- PROVIDE DECONTAMINATION DOORS AND INSTALLATION

Notice Date
9/17/2009
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
238990 — All Other Specialty Trade Contractors
 
Contracting Office
Department of Veterans Affairs;VISN 18;6950 E Williams Field Rd;Mesa AZ 85212
 
ZIP Code
85212
 
Solicitation Number
VA-258-09-RQ-0266-
 
Response Due
9/22/2009
 
Archive Date
11/21/2009
 
Point of Contact
Alan B HandyContract Specialist Intern
 
E-Mail Address
Contract Specialist Intern
(alan.handy@va.gov)
 
Small Business Set-Aside
Total Small Business
 
Description
DESCRIPTION:This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. Solicitation Number VA-258-09-RQ-0266 is being issued as Request for Quote (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular number 2005-36. This requirement is a 100% small business set aside under NAICS Code 238990, Size Standard of $14 Million. REQUIREMENTS: The Raymond G. Murphy VA Medical Center at 1501 San Pedro Dr. SE Albuquerque, NM 87108. The contractor shall provide and install six (6) automatic bifold doors for the DECON Area of the Albuquerque VA Medical Center. The six (6) doors will be placed in two different areas of the medical center. Four (4) sets of automatic bifold doors on shall be installed on each side of the two new DECON Showers and two (2) sets of automatic bifold doors shall be installed on the exterior of the building providing access to the DECON Area. The Doors need to have a clear opening of 72" (2") and a maximum rough opening of 84" (6"). The Doors must meet the following criteria: "Overhead-concealed breakout design with header "door panel(s), jambs " electromechanical self lubricating gear box with microprocessor control " Must have all connecting hardware " Must have actuating controls "On-Off-Hold Open Switch "A 7-pin cylinder "Doors will be installed such that water will not leak through closed doors " Frames shall be aluminum finished appropriately for either shower or outdoor environment "Glazing shall be opaque and view through glazing will be obscured "Doors will be Dorma ED1200 or equal. "Weather proof 6" stainless steel "Push to Open" button engraved with handicap logo and will configure such that doors are push to open and push to close. The contractor will be required to comply with all pertinent statutory health and safety regulations and will staff projects so that there in an OSHA 30 hour trained "competent person" on the job site whenever installation is being accomplished. The following OSHA guidelines are found at: http://www.osha.gov/index.html PRICING AND LINE ITEMS: CLIN 1: Provide and install Four (4) automatic bifold doors on each side of the DECON Showers. Price____________ CLIN 2: Provide and install Two (2) automatic bifold doors to be installed on the exterior of the building providing access to the DECON Area Price____________ Total Cost_______________ CONTRACT PROVISIONS AND CLAUSES: Contract clauses and provisions cited in this solicitation may be accessed electronically at these addresses: http://www.arnet.gov/far/ and http://www.va.gov/oamm/acquisitions/ars/policyreg/vaar/vaar852.htm. In accordance with FAR 52.204.7 - Central Contractor Registration (Oct 2003); contractors are Required To Register in the Central Contractor Registration (CCR) database http://www.ccr.gov, PRIOR to award of any contract. FAR 52.212-1, Instructions to Offerors- Commercial, applies to this acquisition. The following clause applies to this acquisition: FAR 52.212-2 Evaluation-Commercial Items. Evaluation criteria will be based on price. Evaluation may be made with or without discussions with the offeror(s). Offerors are to include a completed copy of the provision at 52.212-3, Offeror Representations and Certifications-Commercial Items with its offer. 52.212-4, Contract Terms and Conditions-Commercial Items applies to this acquisition and the following addenda: VAAR 852.211-77, VAAR 852.228-71. 52.212-5, Contract Terms and Conditions Required To Implement Statutes Or Executive Orders-Commercial Items applies to this acquisition. OFFERS: All responsible sources that meet the VAMC requirements may respond to this solicitation by submitting a quote that provides pricing and availability. Any offer that does not meet the solicitation requirements as deemed by the Contracting Officer may be rejected as non-responsive. Questions regarding this solicitation must be submitted on or before 12:00 p.m. (PST) September 18, 2009 to Daniel Rakes by emailing to Daniel.Rakes@va.gov. All offers must provide company name, point of contact information, the VA solicitation number and the question(s) that you would like answered. No phone calls will be accepted. All final offers must be submitted electronically to Daniel.Rakes@va.gov on or before 12:00pm, (PST) on September 22, 2009.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/PhVAMC/HMC/VA-258-09-RQ-0266-/listing.html)
 
Place of Performance
Address: The Raymond G Murphy;1501 San Pedro Dr. SE;Albuquerque, NM
Zip Code: 87108
 
Record
SN01960232-W 20090919/090918001540-7f2f9a5a4da67f61d060a17959662cae (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.