Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JUNE 27, 2009 FBO #2770
AWARD

Z -- RECOVERY - XUMU 07-1067B REPAIR ROOF AT DELTA IV SOLID ROCKET MOTOR FACILITY

Notice Date
6/25/2009
 
Notice Type
Award Notice
 
NAICS
238160 — Roofing Contractors
 
Contracting Office
Department of the Air Force, Air Force Space Command, 30CONS, 1515 Iceland Avenue, Bldg 8500, Room 150, Vandenberg AFB, California, 93437-5212
 
ZIP Code
93437-5212
 
Solicitation Number
FA4610-05-D-0003_XUMU071067B
 
Point of Contact
Sharon M. May, Phone: (805) 605-2465, David A. Hill, Phone: (805) 605-8470
 
E-Mail Address
sharon.may@vandenberg.af.mil, david.hill2@vandenberg.af.mil
(sharon.may@vandenberg.af.mil, david.hill2@vandenberg.af.mil)
 
Small Business Set-Aside
N/A
 
Award Number
FA4610-05-D-0003-007101
 
Award Date
6/25/2009
 
Awardee
BRAHMA ENGINEERING, INC, 2255 S. BWY STE #8, SANTA MARIA, California 93454, United States
 
Award Amount
$209,960.21
 
Description
This is a Modification. Work consists of removing the existing lightning protection system and components and installing a new catenary's lightning protection system to include surge suppression on in coming power and Comm. The new system shall utilize copper components wherever possible. The LPS is to be designed and installed by an Underwriters Laboratory (UL) certified company. The poles need to be inherent bond type for catenary lightning protection system. Shop drawings shall include site specific layout of existing conditions and new installation. Drawings shall be scaleable and dimensioned with adequate detail, including cross sections if applicable, to demonstrate compliance with installation standards. Design analysis shall be provided to demonstrate compliance with design standards. The UL Master Label has been replaced by the UL Lightning Protection Inspection Certificate. The UL inspection should verify compliance with all referenced standard and the UL certificate should indicated compliance with all referenced standards. Any deficiencies identified by UL must be corrected prior to acceptance. Connections should be cad welded or high compression crimps to ensure longevity. Strike termination devices are not required on metal masts but if included; masts should have strike termination devices molded into the galvanized steel structure not bolted onto the top. System must be installed according to the 100 ft rolling ball distance. Masts must be installed at least the bonding distance or side flash distance but not less than 6 feet. Wire must be a continuous run of at least 6 AWG. Each metal mast must have two connections to the grounding system.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFSC/30CONS/FA4610-05-D-0003_XUMU071067B/listing.html)
 
Place of Performance
Address: 1515 Iceland Ave, Rm 150, Building 8500, Vandenberg AFB, California, 93437-5212, United States
Zip Code: 93437-5212
 
Record
SN01856298-W 20090627/090625235320-98019aeb205f4c0ed633016d1d1f6a29 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers