Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MAY 07, 2009 FBO #2719
SOURCES SOUGHT

99 -- Sources Sought for engineering and technical services to develop and execute a decontamination plan for the WVES Off-Gas Cell. - Technical Documents

Notice Date
5/5/2009
 
Notice Type
Sources Sought
 
NAICS
541330 — Engineering Services
 
Contracting Office
Department of Energy, West Valley Environmental Services Co. (DOE Contractor), West Valley, 10282 Rock Springs Road, West Valley, New York, 14171-9799
 
ZIP Code
14171-9799
 
Solicitation Number
WVES-OffGas
 
Archive Date
5/27/2009
 
Point of Contact
Lynn K. Hollfelder,, Phone: 7169424789
 
E-Mail Address
lynn.hollfelder@wves.org
 
Small Business Set-Aside
N/A
 
Description
Supplier Data Sheet and Business Size Certification Form Radiation and Contamination Survey Reports Technical Drawing-15A-A-159 Rev 5 OGC Technical Drawing-15A-A-154 Rev 5 OGC Technical Drawing-15A-A-122 Rev 5 OGC Off-Gas Cell Scope of Work This is a sources sought announcement only. This is not a solicitation announcement. The purpose of this announcement is to gain knowledge of current market capabilities. There is not a solicitation available at this time. However, upon review of the capabilities statements, WVES will make a determination if the information submitted meets the minimum technical qualification specified and whether to include the organization in any future potential solicitations for the scope of work. Interested organizations should submit their written capability statements by 5:00 pm on May 12, 2009 to the following email address: lynn.hollfelder@wves.org. Please contact Lynn Hollfelder @ (716) 942-4789 or at the above email address with any questions. The proposed scope of work is for the development of plans, design, fabrication/procurement and testing of tooling and operation of a proven decontamination systems for the WVES Off-Gas Cell. Capability statements will not be accepted after the due date. Facsimile transmissions will not be accepted. Capability statements must include company name, address, point of contact, phone/fax/email, and completion of WVES Form WV-0150, "Supplier Data Sheet and Business Size Certification Form." Capability statements shall include documentation that demonstrates the organization's ability to meet the following minimum requirements: Past Experience - Provide supporting documentation demonstrating that your proposed decontamination system/method has a minimum of ten (10) years of proven experience with decontaminating radiation levels and radioisotopes (e.g., Cs-137, Sr-90, AM-241, I-129, and various Uranium and Plutonium isotopes) similar to those specified in the WVES scope of work. The experience shall be specific to Department of Energy (DOE) facilities. Past Performance - Provide supporting documentation demonstrating a minimum of three (3) DOE projects of similar complexity and magnitude which have been performed within the past five (5) years. For each project, provide references which include the Project Manager name, phone number, subcontract number, brief scope of work, period of performance, and dollar value. Remote Operation Capability - Provide supporting documentation demonstrating your decontamination system/method's proven ability to utilize remote handled equipment and tooling for decontaminating and processing radioactive waste. Secondary Waste - Provide supporting documentation demonstrating the effectiveness of your proposed decontamination system/method in minimizing the amount of secondary waste generated during decontamination operations and ensuring that 1) generation of TRU waste is minimal 2) no free liquid shall be present in the final waste container. 3) any waste water generated can be processed to levels less than 5E-3 gross alpha-beta. Quality Assurance Program - Provide supporting documentation demonstrating that your Quality Assurance Program is in accordance with the requirements of ASME NQA-1-1989. Project Engineer/Manager Qualifications - Provide supporting documentation demonstrating a minimum of ten (10) years of strong project engineering/management experience relative to operating your decontamination system. Project Schedule - Provide supporting documentation demonstrating your ability to complete the scope of work within a 18 month schedule. Any proprietary information should be marked as such. Costs shall not be reimbursed for preparation of any information submitted. The following technical documents are attached: 1. Scope of Work for Off-Gas Cell Decon 2. Technical Drawings 3. Radiation and Contamination Survey Reports
 
Web Link
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=37f4fe7552f6f071bd6c4642219987c2&tab=core&_cview=1)
 
Place of Performance
Address: West Valley Demonstration Project, 10282 Rock Springs Road, West Valley, New York, 14171, United States
Zip Code: 14171
 
Record
SN01809935-W 20090507/090505222512-37f4fe7552f6f071bd6c4642219987c2 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.